When a new user accesses the CDMA system, the load will change drastically, and therefore, the advanced outer loop power control (OLPC) technology has to be adopted to enrich the target signal interference ratio (S...When a new user accesses the CDMA system, the load will change drastically, and therefore, the advanced outer loop power control (OLPC) technology has to be adopted to enrich the target signal interference ratio (Silt) and improve the system performance. The existing problems about DS-CDMA outer loop power control for multi-service are introduced and the power control theoretical model is analyzed. System simulation is adopted on how to obtain the theoretical performance and parameter optimization of the power control algorithm. The OLPC algorithm is improved and the performance comparisons between the old algorithm and the improved algorithm are given. The results show good performance of the improved OLPC algorithm and prove the validity of the improved method for multi-service.展开更多
An outer loop power control algorithm based on triangle norm(t-norm) information fusion technology is proposed in this paper.According to the difference between block error rate and bit error rate with target values,t...An outer loop power control algorithm based on triangle norm(t-norm) information fusion technology is proposed in this paper.According to the difference between block error rate and bit error rate with target values,the membership function calculation and level dividing of the two differences are dealt with.And then t-norm operator is used to fuse the two membership function values to determine the adjustment step-size.The algorithm can acquire the optimal adjustment step-size in the light of the channel status and avoid the overshoot phenomenon of the existing outer power control methods.As a result,the block error rate can converge to the target value quickly.Experiment results verify the excellent property of the algorithm.展开更多
An experimental investigation of the saturation ion current densities (Jions) in hydrogen inductively coupled plasma (ICP) produced by a large-power (2-32 kW) radio frequency (RF) generator is reported, then s...An experimental investigation of the saturation ion current densities (Jions) in hydrogen inductively coupled plasma (ICP) produced by a large-power (2-32 kW) radio frequency (RF) generator is reported, then some reasonable explanations are given out. With the increase of RF power, the experimental results show three stages: in the first stage (2-14 kW), the electron temperature will rise with the increase of RF power in the ICP, thus, the Jions increases continually as the electron temperature rises in the ICP. In the second stage (14 20 kW), as some H- ions lead to the mutual neutralization (MN), the slope of Jio^s variation firstly decreases then increases. In the third stage (20-32 kW), both the electronic detachment (ED) and the associative detachment (AD) in the ICP result in the destruction of H- ions, therefore, the increased amplitude of the Jions in the third stage is weaker than the one in the first stage. In addition, with the equivalent transformer model, we successfully Explain that the Jions at different radial locations in ICP has the same rule. Finally, it is found that the Jions has nothing to do with the outer/inner puffing gas pressure ratio, which is attributed to the high-speed movement of hydrogen molecules.展开更多
基金the National Natural Science Foundation of China (60532030).
文摘When a new user accesses the CDMA system, the load will change drastically, and therefore, the advanced outer loop power control (OLPC) technology has to be adopted to enrich the target signal interference ratio (Silt) and improve the system performance. The existing problems about DS-CDMA outer loop power control for multi-service are introduced and the power control theoretical model is analyzed. System simulation is adopted on how to obtain the theoretical performance and parameter optimization of the power control algorithm. The OLPC algorithm is improved and the performance comparisons between the old algorithm and the improved algorithm are given. The results show good performance of the improved OLPC algorithm and prove the validity of the improved method for multi-service.
文摘An outer loop power control algorithm based on triangle norm(t-norm) information fusion technology is proposed in this paper.According to the difference between block error rate and bit error rate with target values,the membership function calculation and level dividing of the two differences are dealt with.And then t-norm operator is used to fuse the two membership function values to determine the adjustment step-size.The algorithm can acquire the optimal adjustment step-size in the light of the channel status and avoid the overshoot phenomenon of the existing outer power control methods.As a result,the block error rate can converge to the target value quickly.Experiment results verify the excellent property of the algorithm.
基金supported by the National Magnetic Confinement Fusion Science Program of China(Nos.2011GB108011 and 2010GB103001)the Major International(Regional)Project Cooperation and Exchanges of China(No.11320101005)the Startup Fund from Fuzhou University(No.510071)
文摘An experimental investigation of the saturation ion current densities (Jions) in hydrogen inductively coupled plasma (ICP) produced by a large-power (2-32 kW) radio frequency (RF) generator is reported, then some reasonable explanations are given out. With the increase of RF power, the experimental results show three stages: in the first stage (2-14 kW), the electron temperature will rise with the increase of RF power in the ICP, thus, the Jions increases continually as the electron temperature rises in the ICP. In the second stage (14 20 kW), as some H- ions lead to the mutual neutralization (MN), the slope of Jio^s variation firstly decreases then increases. In the third stage (20-32 kW), both the electronic detachment (ED) and the associative detachment (AD) in the ICP result in the destruction of H- ions, therefore, the increased amplitude of the Jions in the third stage is weaker than the one in the first stage. In addition, with the equivalent transformer model, we successfully Explain that the Jions at different radial locations in ICP has the same rule. Finally, it is found that the Jions has nothing to do with the outer/inner puffing gas pressure ratio, which is attributed to the high-speed movement of hydrogen molecules.