This paper reports that an output window for optically pumped terahertz (THz) laser has been fabricated by depositing a capacitive nickel-mesh on a thick high-resistivity silicon substrate (approximating to 5 mm th...This paper reports that an output window for optically pumped terahertz (THz) laser has been fabricated by depositing a capacitive nickel-mesh on a thick high-resistivity silicon substrate (approximating to 5 mm thick). Unlike the conventional process of depositing a gold film approximating to 100 nm on negative photoresist using electron-beam evaporation, a nickel film approximating to 1.5 μm thick is directly deposited on the clean surface of dielectric substrate using magnetron sputtering and then a positive photoresist is spun onto the nickel metal surface at 6000 r for 60 s. A transmittance spectrum of the output window in a certain frequency range (say, from zero to 1 THz) has been obtained by using THz time domain spectroscopy. Moreover a transmittance spectrum simulated numerically has also been estimated with respect to the output window using the transmission-line model (TLM) containing attenuation component from dielectric substrate. The simulation results show that the TLM can explain well the experimental curve in a certain frequency range from zero to 1 THz. Thus it is demonstrated that the improved optical component can be efficiently used as both output coupler and output window for optically pumped THz lasers.展开更多
The use of renewable energy is growing significantly in the world. In front of the growing demand for electric energy, essentially for the needs of remote, isolated and mountainous regions, photovoltaic systems, espec...The use of renewable energy is growing significantly in the world. In front of the growing demand for electric energy, essentially for the needs of remote, isolated and mountainous regions, photovoltaic systems, especially water pumping systems, are beginning to emerge in large applications. In this sense, the proposed study deals with the problem of the water level regulation in the photovoltaic pumping system. It is in this context that the interest in this paper is dictated by the need to use an existing energy source on the site. Still in this light, it is important to note that, often, the calculation of the size of the GPV that feeds the pumping system and the pump involves a certain degree of uncertainty, mainly due to two main reasons: the first is related to randomness of solar radiation which is often little known and the second is related to the difficulty to estimate the water needs. This is why, on the one hand, the realization of such a system has made it possible to show the possibility of determining the projected quantity for water storage. Similarly, it has shown that the prediction of this quantity of water can be calculated by a simple analytical method based on numerical computation. Thus, it was also shown for this pumping system, thanks to graphical analysis methods, developing autonomy, reliability and good performance. In this sense, this experience opens the door for a practical and economical solution to the problem of lack of water, especially in our regions. Measurements made on the studied system prove that the designed approach improves the efficiency. Finally, it is also expected to draw further conclusions for the operation of these systems in similar sites.展开更多
For rotating blood pump, the sealing problem is a very important one to solve. In this paper, it was introduced that we designed and made a small axial flow pump, applying the magnetic coupling method. The pump consis...For rotating blood pump, the sealing problem is a very important one to solve. In this paper, it was introduced that we designed and made a small axial flow pump, applying the magnetic coupling method. The pump consisted of two pump housings, a brushless DC motor, an impeller with five wanes, a pair of magnetic discs, a spacer, an inlet and an outlet areas , bearings, a support frame, and etc. The pump is made of titanium and is 125 mm length, 147 ml volume, total 380g of weight. Performances of outputting, sealing, heat creating and damage to blood by the pump were investigated in vitro experiment. Results showed for external experiment that: (1)The pressure created by the pump was 90 mmHg, the flow rates were 1.2 L/min, 4 L/min, 5.9 L/min and 7.8 L/min correspondingly to 5000 rpm, 6000 rpm, 7000 rpm and 8000rpm rotation speeds. The hydrodynamic performance of the axial flow blood pump was enough to meet a patient need when the blood pump was used as a left ventricular assistant device. (2)The hemolysis test was studied by the normalized index of hemolysis(NIH). The NIH result of the axial flow pump was 0.08 g/100 L. (3)The outside temperature of the pump didnt change obviously in 120 hours of rotation, and the sealing function was very well.展开更多
基金Project supported by the Creative Foundation of Wuhan National Laboratory for Optoelectronics (Grant No. Z080007)partly by the National Basic Research Program of China (973 Program)(Grant No. 61328)
文摘This paper reports that an output window for optically pumped terahertz (THz) laser has been fabricated by depositing a capacitive nickel-mesh on a thick high-resistivity silicon substrate (approximating to 5 mm thick). Unlike the conventional process of depositing a gold film approximating to 100 nm on negative photoresist using electron-beam evaporation, a nickel film approximating to 1.5 μm thick is directly deposited on the clean surface of dielectric substrate using magnetron sputtering and then a positive photoresist is spun onto the nickel metal surface at 6000 r for 60 s. A transmittance spectrum of the output window in a certain frequency range (say, from zero to 1 THz) has been obtained by using THz time domain spectroscopy. Moreover a transmittance spectrum simulated numerically has also been estimated with respect to the output window using the transmission-line model (TLM) containing attenuation component from dielectric substrate. The simulation results show that the TLM can explain well the experimental curve in a certain frequency range from zero to 1 THz. Thus it is demonstrated that the improved optical component can be efficiently used as both output coupler and output window for optically pumped THz lasers.
文摘The use of renewable energy is growing significantly in the world. In front of the growing demand for electric energy, essentially for the needs of remote, isolated and mountainous regions, photovoltaic systems, especially water pumping systems, are beginning to emerge in large applications. In this sense, the proposed study deals with the problem of the water level regulation in the photovoltaic pumping system. It is in this context that the interest in this paper is dictated by the need to use an existing energy source on the site. Still in this light, it is important to note that, often, the calculation of the size of the GPV that feeds the pumping system and the pump involves a certain degree of uncertainty, mainly due to two main reasons: the first is related to randomness of solar radiation which is often little known and the second is related to the difficulty to estimate the water needs. This is why, on the one hand, the realization of such a system has made it possible to show the possibility of determining the projected quantity for water storage. Similarly, it has shown that the prediction of this quantity of water can be calculated by a simple analytical method based on numerical computation. Thus, it was also shown for this pumping system, thanks to graphical analysis methods, developing autonomy, reliability and good performance. In this sense, this experience opens the door for a practical and economical solution to the problem of lack of water, especially in our regions. Measurements made on the studied system prove that the designed approach improves the efficiency. Finally, it is also expected to draw further conclusions for the operation of these systems in similar sites.
基金The projectwas supported by National Nine- Five Years Foundation(96 - 90 6 - 0 2 - 14 )
文摘For rotating blood pump, the sealing problem is a very important one to solve. In this paper, it was introduced that we designed and made a small axial flow pump, applying the magnetic coupling method. The pump consisted of two pump housings, a brushless DC motor, an impeller with five wanes, a pair of magnetic discs, a spacer, an inlet and an outlet areas , bearings, a support frame, and etc. The pump is made of titanium and is 125 mm length, 147 ml volume, total 380g of weight. Performances of outputting, sealing, heat creating and damage to blood by the pump were investigated in vitro experiment. Results showed for external experiment that: (1)The pressure created by the pump was 90 mmHg, the flow rates were 1.2 L/min, 4 L/min, 5.9 L/min and 7.8 L/min correspondingly to 5000 rpm, 6000 rpm, 7000 rpm and 8000rpm rotation speeds. The hydrodynamic performance of the axial flow blood pump was enough to meet a patient need when the blood pump was used as a left ventricular assistant device. (2)The hemolysis test was studied by the normalized index of hemolysis(NIH). The NIH result of the axial flow pump was 0.08 g/100 L. (3)The outside temperature of the pump didnt change obviously in 120 hours of rotation, and the sealing function was very well.