A novel copyright protection scheme for digital content is presented, which is a private watermarking scheme based on the watermark embedding in the DCT domain and watermark extraction Using independent component anal...A novel copyright protection scheme for digital content is presented, which is a private watermarking scheme based on the watermark embedding in the DCT domain and watermark extraction Using independent component analysis (ICA). The system includes the key for watermark extraction and the host image. The algorithm splits the original image into blocks and classifies these blocks based on visual masking, that is, noise visibility function (NVF). Watermark components with different strength are inserted into chosen direct current components of DCT coefficients according to the classifier. The watermark extraction is based on the characteristic of the statistic independence of the host image, watermark and key. Principle component analysis (PCA) whitening process and FastICA techniques are introduced to ensure a blind watermark extraction without requiring the original image. Experirnental results show the proposed technique is robust under attacks such as image filtering and adding noise, cropping and resizing. In addition, the proposed private watermarking system can be improved to the application of the DTV content protection system.展开更多
The water pollution situation in Balihe Lake, the biggest tributary of Shaying River Basin in Anhui Province, China, has brought a huge pressure on the improvement of water quality in Huai River. On October 16th, 2017...The water pollution situation in Balihe Lake, the biggest tributary of Shaying River Basin in Anhui Province, China, has brought a huge pressure on the improvement of water quality in Huai River. On October 16th, 2017, 11 major pollution indexes were observed at 15 sampling points in Balihe Lake. Based on the data experimentally measured, the water quality in Balihe Lake was analyzed utilizing the Principal Component Analysis (PCA) of SPSS. The result suggested that the major components were oxygenated pollutants, water eutrophication pollutants and ammonia nitrogen, in which oxygenated pollutants played a dominant role. In addition, the upper part of Balihe Lake suffered serious situation and needed a focus on oxygenated pollutants.展开更多
This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage cir...This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage circuit breakers was analyzed so that measures to improve instantaneous protection reliability can be determined. Furthermore, the theory of the instantaneous characteristics calibration device for low voltage circuit breakers and the method of eliminating the non-periodic component of test current are given in detail. Finally, the test results are presented.展开更多
Symmetrical components method is employed in analysis of the characteristic motor faults.Motor protection method is put forward based on detecting positive sequence,negative sequence and zero sequence current.And prob...Symmetrical components method is employed in analysis of the characteristic motor faults.Motor protection method is put forward based on detecting positive sequence,negative sequence and zero sequence current.And problems of lack of motor overload capacity in existing mining motor protection system,impact of dynamic current on stage and definite-time delay operation and inaccuracy of criterion phase failure protection are analyzed.The unbalanced faults protection and inverse-time overload protection,which can make protection time change with the current movement,are proposed.The above problems can be solved,and the reliability and intelligent of coal shearer are improved.展开更多
Micro-grids comprise low voltage distribution systems with distributed energy resources(DERs) and controllable loads which can operate connected to the medium voltage grid or islanded in a controlled coordinated way. ...Micro-grids comprise low voltage distribution systems with distributed energy resources(DERs) and controllable loads which can operate connected to the medium voltage grid or islanded in a controlled coordinated way. This concept aims to move from "connect and forget" philosophy towards a full integration of DERs. Micro-grids can provide numerous economic and environmental benefits for end-customers, utilities and society. However, their implementation poses great technical challenges, such as a new philosophy in design of protection systems. In this work, a micro-grid protection scheme is presented based on positive-sequence component using phasor measurement units(PMUs) and a central protection unit(CPU). The salient feature of the proposed scheme in comparison with the previous works is that it has the ability to protect both radial and looped micro-grids against different types of faults with the capability of single-phase tripping. Furthermore, since the CPU is capable of updating its pickup values(upstream and downstream equivalent positive-sequence impedances of each line) after the first change in the micro-grid configuration(such as transferring from grid-connected to islanded mode and or disconnection of a line, bus, or DER either in grid-connected mode or in islanded mode), it can protect micro-grid against subsequent faults. Finally, in order to verify the effectiveness of the suggested scheme and the CPU, several simulations have been undertaken by using DIg SILENT Power Factory and MATLAB software packages.展开更多
The research and development of ultra high speed protective relay of transmission line has got great interest and attention of protective relay engineer over the world. Several versions and schemes of ultra high speed...The research and development of ultra high speed protective relay of transmission line has got great interest and attention of protective relay engineer over the world. Several versions and schemes of ultra high speed relay have been studied and designed in recent twenty years. But only a few of them have got actual apiication in the power system. The relay based on the deviation of power frequency component (DPFC) can get very high reliability with ultra high speed so it has got wide application in Chinese power system. Thousands relay sets have been applied and its operation experience verifies their excellent performance. This paper summarizes the course of the development of the uItra high speed protective relay and compares the merits and defects of the main schemes which have been developed. The principle and successful pratice of the ultra high speed protection based on DPFC reIay are introduced.展开更多
Current phase comparison based pilot protection had been generally utilized as primary protection of the transmission lines in China from the 1950’s to the 1980’s. Conventional phase comparison pilot protection has ...Current phase comparison based pilot protection had been generally utilized as primary protection of the transmission lines in China from the 1950’s to the 1980’s. Conventional phase comparison pilot protection has a long phase comparison time, which results in a longer fault-clearing time. This paper proposes a new current phase comparison pilot protection scheme that is based on non-power frequency fault current component. The phase of the fourth harmonic current of each end of the protected line has been abstracted by utilizing complex wavelet transformation and then compared in order to determine whether the inner fault occurs or not. This way can greatly decrease fault-clearing time and improve performances of this pilot protection when fault occurs under the heavy-load current and asymmetrical operation conditions. Many EMTP simulations have verified the proposed scheme’s correctness and effectiveness.展开更多
The setting work of backup protection using steady-state current is tedious,and mismatches occasionally occur due to the increased proportion of distributed generations(DGs)connected to the power grid.Thus,there is a ...The setting work of backup protection using steady-state current is tedious,and mismatches occasionally occur due to the increased proportion of distributed generations(DGs)connected to the power grid.Thus,there is a practical need to study a backup protection technology that does not require step-by-step setting and can be adaptively coordinated.This paper proposes an action sequence adaptive to fault positions that uses only positive sequence fault component(PSFC)voltage.Considering the influence of DGs,the unified time dial setting can be obtained by selecting specific points.The protection performance is improved by using the adjacent upstream and downstream protections to meet the coordination time interval in the case of metallic faults at the near-and far-ends of the line.Finally,the expression and implementation scheme for inverse-time backup protection(ITBP)based on the unified characteristic equation is given.Simulation results show that this scheme can adapt to DG penetration scenarios and can realize the adaptive coordination of multi-level relays.展开更多
基金This project was supported by the Digital TV Special Foundation of National Development and Reform Commission ofChina (040313) Home Coming Scholars Science Activity Foundation of Ministry of Personnel (20041231) the Graduate In-novation Foundation of Xidian University (innovaion 0509)
文摘A novel copyright protection scheme for digital content is presented, which is a private watermarking scheme based on the watermark embedding in the DCT domain and watermark extraction Using independent component analysis (ICA). The system includes the key for watermark extraction and the host image. The algorithm splits the original image into blocks and classifies these blocks based on visual masking, that is, noise visibility function (NVF). Watermark components with different strength are inserted into chosen direct current components of DCT coefficients according to the classifier. The watermark extraction is based on the characteristic of the statistic independence of the host image, watermark and key. Principle component analysis (PCA) whitening process and FastICA techniques are introduced to ensure a blind watermark extraction without requiring the original image. Experirnental results show the proposed technique is robust under attacks such as image filtering and adding noise, cropping and resizing. In addition, the proposed private watermarking system can be improved to the application of the DTV content protection system.
文摘The water pollution situation in Balihe Lake, the biggest tributary of Shaying River Basin in Anhui Province, China, has brought a huge pressure on the improvement of water quality in Huai River. On October 16th, 2017, 11 major pollution indexes were observed at 15 sampling points in Balihe Lake. Based on the data experimentally measured, the water quality in Balihe Lake was analyzed utilizing the Principal Component Analysis (PCA) of SPSS. The result suggested that the major components were oxygenated pollutants, water eutrophication pollutants and ammonia nitrogen, in which oxygenated pollutants played a dominant role. In addition, the upper part of Balihe Lake suffered serious situation and needed a focus on oxygenated pollutants.
基金Project (No. 043804411) supported by the Tianjin Natural ScienceFoundation, China
文摘This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage circuit breakers was analyzed so that measures to improve instantaneous protection reliability can be determined. Furthermore, the theory of the instantaneous characteristics calibration device for low voltage circuit breakers and the method of eliminating the non-periodic component of test current are given in detail. Finally, the test results are presented.
文摘Symmetrical components method is employed in analysis of the characteristic motor faults.Motor protection method is put forward based on detecting positive sequence,negative sequence and zero sequence current.And problems of lack of motor overload capacity in existing mining motor protection system,impact of dynamic current on stage and definite-time delay operation and inaccuracy of criterion phase failure protection are analyzed.The unbalanced faults protection and inverse-time overload protection,which can make protection time change with the current movement,are proposed.The above problems can be solved,and the reliability and intelligent of coal shearer are improved.
文摘Micro-grids comprise low voltage distribution systems with distributed energy resources(DERs) and controllable loads which can operate connected to the medium voltage grid or islanded in a controlled coordinated way. This concept aims to move from "connect and forget" philosophy towards a full integration of DERs. Micro-grids can provide numerous economic and environmental benefits for end-customers, utilities and society. However, their implementation poses great technical challenges, such as a new philosophy in design of protection systems. In this work, a micro-grid protection scheme is presented based on positive-sequence component using phasor measurement units(PMUs) and a central protection unit(CPU). The salient feature of the proposed scheme in comparison with the previous works is that it has the ability to protect both radial and looped micro-grids against different types of faults with the capability of single-phase tripping. Furthermore, since the CPU is capable of updating its pickup values(upstream and downstream equivalent positive-sequence impedances of each line) after the first change in the micro-grid configuration(such as transferring from grid-connected to islanded mode and or disconnection of a line, bus, or DER either in grid-connected mode or in islanded mode), it can protect micro-grid against subsequent faults. Finally, in order to verify the effectiveness of the suggested scheme and the CPU, several simulations have been undertaken by using DIg SILENT Power Factory and MATLAB software packages.
文摘The research and development of ultra high speed protective relay of transmission line has got great interest and attention of protective relay engineer over the world. Several versions and schemes of ultra high speed relay have been studied and designed in recent twenty years. But only a few of them have got actual apiication in the power system. The relay based on the deviation of power frequency component (DPFC) can get very high reliability with ultra high speed so it has got wide application in Chinese power system. Thousands relay sets have been applied and its operation experience verifies their excellent performance. This paper summarizes the course of the development of the uItra high speed protective relay and compares the merits and defects of the main schemes which have been developed. The principle and successful pratice of the ultra high speed protection based on DPFC reIay are introduced.
基金Sponsored by the Power Electrical Science and Technology Foundation of XJ Group and the Shanghai University Foundation for Excellent Young Teacher.
文摘Current phase comparison based pilot protection had been generally utilized as primary protection of the transmission lines in China from the 1950’s to the 1980’s. Conventional phase comparison pilot protection has a long phase comparison time, which results in a longer fault-clearing time. This paper proposes a new current phase comparison pilot protection scheme that is based on non-power frequency fault current component. The phase of the fourth harmonic current of each end of the protected line has been abstracted by utilizing complex wavelet transformation and then compared in order to determine whether the inner fault occurs or not. This way can greatly decrease fault-clearing time and improve performances of this pilot protection when fault occurs under the heavy-load current and asymmetrical operation conditions. Many EMTP simulations have verified the proposed scheme’s correctness and effectiveness.
基金supported in part by the National Natural Science Foundation of China(NSFC-UKRI_EPSRC)(No.52061635105)in part by the Science and Technology Program of SGCC(No.5100-202040327A-0-0-00).
文摘The setting work of backup protection using steady-state current is tedious,and mismatches occasionally occur due to the increased proportion of distributed generations(DGs)connected to the power grid.Thus,there is a practical need to study a backup protection technology that does not require step-by-step setting and can be adaptively coordinated.This paper proposes an action sequence adaptive to fault positions that uses only positive sequence fault component(PSFC)voltage.Considering the influence of DGs,the unified time dial setting can be obtained by selecting specific points.The protection performance is improved by using the adjacent upstream and downstream protections to meet the coordination time interval in the case of metallic faults at the near-and far-ends of the line.Finally,the expression and implementation scheme for inverse-time backup protection(ITBP)based on the unified characteristic equation is given.Simulation results show that this scheme can adapt to DG penetration scenarios and can realize the adaptive coordination of multi-level relays.