期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Simulation Research of Transient Over-voltage on High-voltage Shunt Capacitor Banks
1
作者 HU Quan-wei ZHOU Xing-xing +3 位作者 SI Wen-rong ZHANG Yang LI Jun-hao LI Yan-ming 《高压电器》 CAS CSCD 北大核心 2011年第9期37-43,共7页
With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor b... With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor banks will bear large numbers of over-voltage inevitably.If the over-voltage exceeds certain amplitude,the capacitor will be damaged.This paper aims at the capacitor banks in the 35 kV side of Shanghai Xu-xing 500 kV substation,and applies ATP-EMTP to simulate the over-voltages generated by operating the switches under different angles of the source.Finally,according to the results of simulation and theoretical analysis,a best choice(i.e.angles of the source) to switch on capacitor banks is proposed.In this case the over-voltage on the capacitor will be limited to lowest. 展开更多
关键词 capacitor banks operating over-voltage EMTP SIMULATION
下载PDF
The Study on New Solid-State Breaker and Its Over-voltage Suppression Technique
2
作者 Longji Zhu Yan Zheng 《Energy and Power Engineering》 2013年第4期1249-1252,共4页
A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, t... A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, to the IGCT’s over-voltage sensitivity problem, a new technique of reducing the over-voltage is introduced, which releases the elect romantics energy of faulty line by a capacitive current branch to reduce the amplitude of over-voltage. Secondly, the principle of over-voltage suppression with current release branch is analyzed, and the overall control scheme of solid- state breaker is put forward. Finally, the simulation results also demonstrate its obvious effectiveness in over-voltage suppression after adding a current release branch into the SSB. 展开更多
关键词 SOLID-STATE BREAKER IGCT over-voltage SUPPRESSION Current Release CIRCUIT
下载PDF
AN APPLICATION OF BIFURCATION OF PERIODIC SOLUTIONS TO FERRORESONANCE OVER-VOLTAGE IN POWER SYSTEMS 被引量:2
3
作者 赖定文 王政贤 《Chinese Science Bulletin》 SCIE EI CAS 1991年第19期1601-1605,共5页
Ferroresonance over-voltage is a destructive factor in power systems and keeps on causing accidents. So far no correct approaches have been found in the theoretical analysis of this complex physical process. In order ... Ferroresonance over-voltage is a destructive factor in power systems and keeps on causing accidents. So far no correct approaches have been found in the theoretical analysis of this complex physical process. In order to avoid difficulties, people usually explain the mechanism of ferroresonance over-voltage with the help of the knowledge about resonance in nonlinear oscillating systems with single degree of freedom. From this point of view, some measures of removing ferroresonance over-voltage have been proposed. However, power systems are not definitely the systems with single degree of freedom, the aforementioned explana- 展开更多
关键词 BIFURCATION of periodic solution integral MANIFOLD FERRORESONANCE over-voltage.
原文传递
Large-Scale Renewable Energy Transmission by HVDC: Challenges and Proposals 被引量:4
4
作者 Weisheng Wang Guanghui Li Jianbo Guo 《Engineering》 SCIE EI CAS 2022年第12期252-267,共16页
Renewable energy transmission by high-voltage direct current(HVDC)has attracted increasing attention for the development and utilization of large-scale renewable energy under the Carbon Peak and Carbon Neutrality Stra... Renewable energy transmission by high-voltage direct current(HVDC)has attracted increasing attention for the development and utilization of large-scale renewable energy under the Carbon Peak and Carbon Neutrality Strategy in China.High-penetration power electronic systems(HPPESs)have gradually formed at the sending end of HVDC transmission.The operation of such systems has undergone profound changes compared with traditional power systems dominated by synchronous generators.New stability issues,such as broadband oscillation and transient over-voltage,have emerged,causing tripping accidents in large-scale renewable energy plants.The analysis methods and design principles of traditional power systems are no longer suitable for HPPESs.In this paper,the mechanisms of broadband oscillation and transient over-voltage are revealed,and analytical methods are proposed for HPPESs,including small-signal impedance analysis and electromagnetic transient simulation.Validation of the theoretical research has been accomplished through its application in several practical projects in north,northwest,and northeast region of China.Finally,suggestions for the construction and operation of the future renewable-energy-dominated power system are put forward. 展开更多
关键词 Broadband oscillation Future power system HVDC transmission Renewable energy generation Transient over-voltage
下载PDF
Repeated Strike Process During Disconnector Operation in Ultra-High Voltage Gas-Insulated Switchgear 被引量:1
5
作者 关永刚 蔡元纪 +4 位作者 陈维江 刘卫东 李志兵 岳功昌 张俊民 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第3期247-253,共7页
Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investiga... Very fast transient over-voltage (VFTO), induced by disconnector operations in gas- insulated switchgears, has become the limiting dielectric stress at ultra-high voltage levels. Much work has been done to investigate single-strike waveforms of VFTO. However, little study has been carried out investigating the repeated strike process, which would influence VFTO significantly. In this paper, we carried out 450 effective experiments in an ultra-high voltage test circuit, and conducted calculations through the Monte Carlo simulation method, to investigate the repeated strike process. Firstly, the mechanism of the repeated strike process is proposed, based on the ex- perimentai results. Afterwards, statistical breakdown characteristics of disconnectors are obtained and analyzed. Finally, simulations of the repeated strike process are conducted, which indicate that the dielectric strength recovery speed and polarity effect factor have a joint effect on VFTO. This study enhances the understanding of the nature of VFTO, and may help to optimize the disconnector designed to minimize VFTO. 展开更多
关键词 disconnector (DS) repeated strike process DISCHARGE statistical breakdowncharacteristics ultra-high voltage (UHV) very fast transient over-voltage (VFTO)
下载PDF
Research on Reverse Recovery Transient of Parallel Thyristors for Fusion Power Supply
6
作者 查烽炜 宋执权 +2 位作者 傅鹏 董琳 王敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第7期716-720,共5页
In nuclear fusion power supply systems, the thyristors often need to be connected in parallel for sustaining large current. However, research on the reverse recovery transient of parallel thyristors has not been repor... In nuclear fusion power supply systems, the thyristors often need to be connected in parallel for sustaining large current. However, research on the reverse recovery transient of parallel thyristors has not been reported yet. When several thyristors are connected in parallel,they cannot turn-off at the same moment, and thus the turn-off model based on a single thyristor is no longer suitable. In this paper, an analysis is presented for the reverse recovery transient of parallel thyristors. Parallel thyristors can be assumed as one virtual thyristor so that the reverse recovery current can be modeled by an exponential function. Through equivalent transformation of the rectifier circuit, the commutating over-voltage can be calculated based on Kirchhoff’s equation. The reverse recovery current and commutation over-voltage waveforms are measured on an experiment platform for a high power rectifier supply. From the measurement results, it is concluded that the modeling method is acceptable. 展开更多
关键词 parallel thyristors reverse recovery transient commutating over-voltage high power rectifier
下载PDF
Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
7
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
下载PDF
A novel algorithm for frequency dependent modeling of ferrite ring and its optimum design to study VFTO behaviors within GIS
8
作者 Mehrdad MAJIDI Hamid JAVADI Moein MANBACHI 《Frontiers in Energy》 SCIE CSCD 2014年第1期90-100,共11页
One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order ... One of the fundamental issues in gas insulated substations (GIS) which has destructive effects on GIS equipment is the very fast transient over-voltages (VFTOs). This paper models a 400/230 kV substation in order to study the effects of VFTO extensively implemen- ted on EMTP-RV. In addition, the application of ferrite rings for suppressing VFTOs is assessed thoroughly. The main advantage of this paper is its new proposed algorithm according to the ferrite ring frequency dependent modeling that is validated with experimental results. This paper examines the effects of three compositions of the ferrite ring on VFTO suppression. Moreover, it estimates the dimension of the ferrite ring based on the SF6 gas insulation withstand and the maximum effect of ferrite rings on VFTO suppression constraint with the COMSOL multiphysics software. Furthermore, it gains VFTO attenuated percentages due to the installation of the ferrite ring in different GIS nodes. Finally, it analyzes the offered VFTO amendment technique in various GIS switching scenarios. 展开更多
关键词 comsol multiphysics EMTP-RV ferrite ring gas insulated substations (GIS) transient over-voltage insulation coordination
原文传递
上一页 1 下一页 到第