期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Summary of Useful Concepts About the Coordination of Directional Overcurrent Protections 被引量:1
1
作者 Elmer Sorrentino Naren Gupta 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2019年第3期382-390,共9页
This paper summarizes some useful concepts about the coordination of directional overcurrent protections.The following key topics are described:the analysis of systems in a ring configuration and only one source of sh... This paper summarizes some useful concepts about the coordination of directional overcurrent protections.The following key topics are described:the analysis of systems in a ring configuration and only one source of short-circuit currents;the impossibility of obtaining selectivity for all the possible system configurations with multiple sources;the need for inverse functions in order to obtain selectivity in systems with multiple sources;the coordination with protections for radial loads;the coordination between instantaneous and delayed functions;the considerations to select the pickup values;the influence of contributions from motors to short circuit currents;the transient configurations due to sequential trips at both line ends;the influence of dynamic behavior of overcurrent functions;the influence of stability constraints;other specific considerations for ground functions;some specific considerations for systems with distributed generation.A summary of these points and their effect on the coordination of directional overcurrent protections is not available in the current literature.This novel description should facilitate the inclusion of these key points in research and coordination studies related to these protective functions. 展开更多
关键词 Coordination of protective relays directional overcurrent protection directional overcurrent relays directional overcurrent functions power system protection
原文传递
IEC61850 standard-based harmonic blocking scheme for power transformers
2
作者 Senthil Krishnamurthy Bwandakassy Elenga Baningobera 《Protection and Control of Modern Power Systems》 2019年第1期123-137,共15页
Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks th... Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks the relay tripping during the transformer magnetizing inrush conditions. However, the backup overcurrent relay (SEL751A) applied to the transformer protection does not have harmonic restraint element and trip the overcurrent relay during the inrush conditions. Therefore, major contribution of this research work is the developed harmonic blocking scheme for transformer which uses element (87HB) of the transformer differential relay (SEL487E) to send an IEC61850 GOOSE-based harmonic blocking signal to the backup overcurrent relay (SEL751A) to inhibit from tripping during the transformer magnetizing inrush current conditions. The simulation results proved that IEC61850 standard-based protection scheme is faster than the hardwired signals. Therefore, the speed and reliability of the transformer scheme are improved using the IEC61850 standard-based GOOSE applications. 展开更多
关键词 Transformer protection overcurrent protection Digital protection scheme Current differential protection Transformer magnetizing inrush current Harmonic blocking IEC 61850 GOOSE message
原文传递
Transient stability enhancement of DC-connected DFIG and its converter system using fault protective device 被引量:2
3
作者 Shaomin YAN Aimin ZHANG +2 位作者 Hang ZHANG Jianhua WANG Bin CAI 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第6期887-896,共10页
Transient stability of doubly-fed induction generators(DFIGs)is a major concern in both AC and DC grids,and DFIGs must stay connected for a time during grid faults according to the power grid requirements.For this pur... Transient stability of doubly-fed induction generators(DFIGs)is a major concern in both AC and DC grids,and DFIGs must stay connected for a time during grid faults according to the power grid requirements.For this purpose,this work proposes an overcurrent and overvoltage protective device(OCV-PD)to ensure that DCbased DFIG system can stay connected and operate well during the faults.Compared with a series dynamic braking resistor(SDBR),two aspects are improved.First,a twolevel control strategy and DC inductor circuit are used to ensure that the OCV-PD can limit the current impulse to protect DFIG system during an overcurrent fault.Second,the OCV-PD can protect system from overvoltage fault which a SDBR cannot do.Simulation results verify itsvalidity and feasibility,finding that for overcurrent protection the OCV-PD outperforms a SDBR with an average decreased index of 3.29%,and for overvoltage protection it achieves an average index of 1.02%. 展开更多
关键词 Transient stability Doubly-fed induction generator(DFIG) overcurrent and overvoltage protective device(OCV-PD) DC grid Series dynamic braking resistor(SDBR)
原文传递