In this paper, we present a nonorthogonal overlapping Yee method for solv- ing Maxwell's equations using the diagonal split-cell model. When material interface is presented, the diagonal split-cell model does not req...In this paper, we present a nonorthogonal overlapping Yee method for solv- ing Maxwell's equations using the diagonal split-cell model. When material interface is presented, the diagonal split-cell model does not require permittivity averaging so that better accuracy can be achieved. Our numerical results on optical force computation show that the standard FDTD method converges linearly, while the proposed method achieves quadratic convergence and better accuracy.展开更多
An online hybrid test was carried out on a 40-story 120-m high concrete shear wall structure. The structure was divided into two substructures whereby a physical model of the bottom three stories was tested in the lab...An online hybrid test was carried out on a 40-story 120-m high concrete shear wall structure. The structure was divided into two substructures whereby a physical model of the bottom three stories was tested in the laboratory and the upper 37 stories were simulated numerically using ABAQUS. An overlapping domain method was employed for the bottom three stories to ensure the validity of the boundary conditions of the superstructure. Mixed control was adopted in the test. Displacement control was used to apply the horizontal displacement, while two controlled force actuators were applied to simulate the overturning moment, which is very large and cannot be ignored in the substructure hybrid test of high-rise buildings. A series of tests with earthquake sources of sequentially increasing intensities were carried out. The test results indicate that the proposed hybrid test method is a solution to reproduce the seismic response of high-rise concrete shear wall buildings. The seismic performance of the tested precast high-rise building satisfies the requirements of the Chinese seismic design code.展开更多
A basic calculation procedure for the MOSMO method under CNDO/2 approximation is presented in this paper,and performed by using the same parameters as those used in the ordinary CNDO/2 LCAO-MO calculation.The calculat...A basic calculation procedure for the MOSMO method under CNDO/2 approximation is presented in this paper,and performed by using the same parameters as those used in the ordinary CNDO/2 LCAO-MO calculation.The calculated results on the whole are close to those obtained by use of the ordinary CNDO/2 LCAO-MO calculation,illustrating that the presented procedure is reasonable.Due to its simplicity,the presented calculation procedure may be feasible even in very large molecular s ystems.展开更多
基金supported by the Air Force Office of Scientific Research (AFOSR) under Grant numbers FA9550-04-1-0213 and FA9550-07-1-0010
文摘In this paper, we present a nonorthogonal overlapping Yee method for solv- ing Maxwell's equations using the diagonal split-cell model. When material interface is presented, the diagonal split-cell model does not require permittivity averaging so that better accuracy can be achieved. Our numerical results on optical force computation show that the standard FDTD method converges linearly, while the proposed method achieves quadratic convergence and better accuracy.
基金State Key Research Project in 13th Five-Year under Grant No.2016YFC0701901the Beijing Science and Technology Program under Grant No.Z161100001216015the Natural Science Foundation of China under Grants Nos.51422809 and 51778342
文摘An online hybrid test was carried out on a 40-story 120-m high concrete shear wall structure. The structure was divided into two substructures whereby a physical model of the bottom three stories was tested in the laboratory and the upper 37 stories were simulated numerically using ABAQUS. An overlapping domain method was employed for the bottom three stories to ensure the validity of the boundary conditions of the superstructure. Mixed control was adopted in the test. Displacement control was used to apply the horizontal displacement, while two controlled force actuators were applied to simulate the overturning moment, which is very large and cannot be ignored in the substructure hybrid test of high-rise buildings. A series of tests with earthquake sources of sequentially increasing intensities were carried out. The test results indicate that the proposed hybrid test method is a solution to reproduce the seismic response of high-rise concrete shear wall buildings. The seismic performance of the tested precast high-rise building satisfies the requirements of the Chinese seismic design code.
文摘A basic calculation procedure for the MOSMO method under CNDO/2 approximation is presented in this paper,and performed by using the same parameters as those used in the ordinary CNDO/2 LCAO-MO calculation.The calculated results on the whole are close to those obtained by use of the ordinary CNDO/2 LCAO-MO calculation,illustrating that the presented procedure is reasonable.Due to its simplicity,the presented calculation procedure may be feasible even in very large molecular s ystems.