A double-parameter oxygen lance used in a 300 t converter was designed to improve the metallurgical performance. A small-scale measurement of the jet behavior was done using a computer controlled scanning system. The ...A double-parameter oxygen lance used in a 300 t converter was designed to improve the metallurgical performance. A small-scale measurement of the jet behavior was done using a computer controlled scanning system. The experimental data on the velocity distribution at the jet centerline, the contour map of the jet velocity, the deviation of the jet centerline, and the velocity distribution of the axial section were compiled. According to the results of the small-scale measurement, the double-parameter lance was also employed for a BOF experiment. The metallurgy inde- xes show that the metallurgical performance was highly promoted by use of the double-parameter lance.展开更多
Based on the operating conditions of oxygen lance utilized for a 50 t converter in Tangsteel,gas jet flow fields of three types of oxygen lances were simulated by FLUENT software.The influence of lance configuration a...Based on the operating conditions of oxygen lance utilized for a 50 t converter in Tangsteel,gas jet flow fields of three types of oxygen lances were simulated by FLUENT software.The influence of lance configuration and lance level on penetrating area was studied through cold model experiment.The results showed that the gas flow velocities of four-hole,variable angle four-hole and five-hole oxygen lances declined rapidly with an increase in gas jet length within 1 m,1 m and 0.8 m,respectively.Besides,the multi gas streams sprayed from these three lances should be syncretized at 1.6 m,1.7 m and 1.4 m,respectively.At the highest lance level,the effective penetrating area of these three lances could be 0.255 m2,0.385 m2 and 0.0907 m2,respectively.It was suggested that the effective penetrating area of variable angle four-hole oxygen lance was the biggest,while that of five-hole oxygen lance was the least.The validity of numerical simulation results was proved through cold model experiment.The lance level was suggested to be controlled in the range of 1-1.6 m,1-1.7 m and 0.8-1.4 m for the four-hole,variable angle four-hole and five-hole oxygen lances,respectively.展开更多
文摘A double-parameter oxygen lance used in a 300 t converter was designed to improve the metallurgical performance. A small-scale measurement of the jet behavior was done using a computer controlled scanning system. The experimental data on the velocity distribution at the jet centerline, the contour map of the jet velocity, the deviation of the jet centerline, and the velocity distribution of the axial section were compiled. According to the results of the small-scale measurement, the double-parameter lance was also employed for a BOF experiment. The metallurgy inde- xes show that the metallurgical performance was highly promoted by use of the double-parameter lance.
文摘Based on the operating conditions of oxygen lance utilized for a 50 t converter in Tangsteel,gas jet flow fields of three types of oxygen lances were simulated by FLUENT software.The influence of lance configuration and lance level on penetrating area was studied through cold model experiment.The results showed that the gas flow velocities of four-hole,variable angle four-hole and five-hole oxygen lances declined rapidly with an increase in gas jet length within 1 m,1 m and 0.8 m,respectively.Besides,the multi gas streams sprayed from these three lances should be syncretized at 1.6 m,1.7 m and 1.4 m,respectively.At the highest lance level,the effective penetrating area of these three lances could be 0.255 m2,0.385 m2 and 0.0907 m2,respectively.It was suggested that the effective penetrating area of variable angle four-hole oxygen lance was the biggest,while that of five-hole oxygen lance was the least.The validity of numerical simulation results was proved through cold model experiment.The lance level was suggested to be controlled in the range of 1-1.6 m,1-1.7 m and 0.8-1.4 m for the four-hole,variable angle four-hole and five-hole oxygen lances,respectively.