Mechanical degradation, especially fractures in active particles in an electrode, is a major reason why the capacity of lithiumion batteries fades. This paper proposes a model that couples Li-ion diffusion, stress evo...Mechanical degradation, especially fractures in active particles in an electrode, is a major reason why the capacity of lithiumion batteries fades. This paper proposes a model that couples Li-ion diffusion, stress evolution, and damage mechanics to simulate the growth of central cracks in cathode particles(Li Mn_2 O_4) by an extended finite element method by considering the influence of multiple factors. The simulation shows that particles are likely to crack at a high discharge rate, when the particle radius is large, or when the initial central crack is longer. It also shows that the maximum principal tensile stress decreases and cracking becomes more difficult when the influence of crack surface diffusion is considered. The fracturing process occurs according to the following stages: no crack growth, stable crack growth, and unstable crack growth. Changing the charge/discharge strategy before unstable crack growth sets in is beneficial to prevent further capacity fading during electrochemical cycling.展开更多
Paracetamol (PCM) is enlisted in the WHO model list as an essential medicine for pain and palliative care, but at overdose, it causes hepatic damage. This study was designed to assess the analgesic efficacy and hepato...Paracetamol (PCM) is enlisted in the WHO model list as an essential medicine for pain and palliative care, but at overdose, it causes hepatic damage. This study was designed to assess the analgesic efficacy and hepatoprotective property of a solid dispersion (SD) loaded with PCM. A number of PCM loaded formulations (PSDs) were fabricated using silica alone or in combination with polyethylene glycol and/or Na-citrate followed by in-vitro dissolution profiling. Selected PSDs with improved dissolution profile were subjected to solid-state characterization (DSC, PXRD, FTIR, and SEM), stability study along with investigation of in-vivo analgesic efficacy and effect on hepatocytes. Among these, PSD10 showed a rapid and significantly higher in-vitro drug release than pure PCM. This improvement was distinct to other PSDs also. Solid-state characterization of PSD10 authenticated the conversion of crystalline PCM to amorphous form upon formulation. Subsequent oral administration of PSD10 in Swiss albino mice showed 1.44-fold greater analgesic efficacy than pure PCM at dose 30 mg/kg. Besides, at acute toxic dose, liver histology of PSD10 mice was comparable with NC mice indicating hepatic protection upon formulation, whereas the PCM mice showed extensive hepatic necrosis which was also endorsed by significantly higher values of SGPT, SGOT, and ALP than PSD10 mice. Finally, an accelerated stability study of PSD10 performed according to the guideline of ICH noticed no remarkable deviation in its dissolution performance as well as crystalline nature. Thus, this newly developed PSD10 may be a safe and promising alternative for pain management and palliative care.展开更多
基金support of the National Natural Science Foundation of China (11472165 and 11332005)
文摘Mechanical degradation, especially fractures in active particles in an electrode, is a major reason why the capacity of lithiumion batteries fades. This paper proposes a model that couples Li-ion diffusion, stress evolution, and damage mechanics to simulate the growth of central cracks in cathode particles(Li Mn_2 O_4) by an extended finite element method by considering the influence of multiple factors. The simulation shows that particles are likely to crack at a high discharge rate, when the particle radius is large, or when the initial central crack is longer. It also shows that the maximum principal tensile stress decreases and cracking becomes more difficult when the influence of crack surface diffusion is considered. The fracturing process occurs according to the following stages: no crack growth, stable crack growth, and unstable crack growth. Changing the charge/discharge strategy before unstable crack growth sets in is beneficial to prevent further capacity fading during electrochemical cycling.
文摘Paracetamol (PCM) is enlisted in the WHO model list as an essential medicine for pain and palliative care, but at overdose, it causes hepatic damage. This study was designed to assess the analgesic efficacy and hepatoprotective property of a solid dispersion (SD) loaded with PCM. A number of PCM loaded formulations (PSDs) were fabricated using silica alone or in combination with polyethylene glycol and/or Na-citrate followed by in-vitro dissolution profiling. Selected PSDs with improved dissolution profile were subjected to solid-state characterization (DSC, PXRD, FTIR, and SEM), stability study along with investigation of in-vivo analgesic efficacy and effect on hepatocytes. Among these, PSD10 showed a rapid and significantly higher in-vitro drug release than pure PCM. This improvement was distinct to other PSDs also. Solid-state characterization of PSD10 authenticated the conversion of crystalline PCM to amorphous form upon formulation. Subsequent oral administration of PSD10 in Swiss albino mice showed 1.44-fold greater analgesic efficacy than pure PCM at dose 30 mg/kg. Besides, at acute toxic dose, liver histology of PSD10 mice was comparable with NC mice indicating hepatic protection upon formulation, whereas the PCM mice showed extensive hepatic necrosis which was also endorsed by significantly higher values of SGPT, SGOT, and ALP than PSD10 mice. Finally, an accelerated stability study of PSD10 performed according to the guideline of ICH noticed no remarkable deviation in its dissolution performance as well as crystalline nature. Thus, this newly developed PSD10 may be a safe and promising alternative for pain management and palliative care.