To solve the low power transfer efficiency and magnetic field leakage problems of cardiac pacemaker wireless powering, we proposed a wireless power supply system suitable for implanted cardiac pacemaker based on mu-ne...To solve the low power transfer efficiency and magnetic field leakage problems of cardiac pacemaker wireless powering, we proposed a wireless power supply system suitable for implanted cardiac pacemaker based on mu-negative(MNG) and mu-nearzero(MNZ) metamaterials. First, a hybrid metamaterial consisted of central MNG unit for magnetic field concentration and surrounding MNZ units for magnetic leakage shielding was established by theoretical calculation. Afterwards, the magnetic field distribution of wireless power supply system with MNG-MNZ metamaterial slab was acquired via finite element simulation and verified to be better than the distribution with conventional MNG slab deployed. Finally, an experimental platform of wireless power supply system was established with which power transfer experiment and system temperature rise experiment were conducted.Simulation and experimental results showed that the power transfer efficiency was improved from 44.44%,19.42%, 8.63% and 6.19% to 55.77%, 62.39%, 20.81%and 14.52% at 9.6 mm, 20 mm, 30 mm and 50 mm,respectively. The maximum SAR acquired by SAR simulation under human body environment was-7.14 dbm and maximum reduction of the magnetic field strength around the receiving coil was 2.82 A/m. The maximum temperature rise during 30min charging test was 3.85℃,and the safety requirements of human bodies were met.展开更多
Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized ...Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized controlled trials has resulted in an exponential rise in the use of TAVR even in the low-risk patients.However,this is not without challenges.Need for permanent pacemaker(PPM)post-TAVR remains the most frequent and clinically relevant challenge.Naturally,identifying risk factors which predispose an individual to develop high grade conduction block post-TAVR is important.Various demographic factors,electrocardiographic features,anatomic factors and procedural characteristics have all been linked to the development of advanced conduction block and need for PPM following TAVR.Amongst these electrophysiological variables,most notably a prolonged QRS>120 ms regardless of the type of conduction block seems to be one of the strongest predictors on logistic regression models.The index study by Nwaedozie et al highlights that patients requiring PPM post-TAVR had higher odds of having a baseline QRS>120 ms and were more likely to be having diabetes mellitus that those who did not require PPM.展开更多
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from...In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR.展开更多
Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have a...Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have at least as much impact on the final need for a permanent pacemaker and potentially on the pacing rate.In this regard,long-term follow-up and understanding of the impact of long-term stimulation is of utmost importance.展开更多
Background: Pacemaker implantation is a very old activity which has revolutionized the cardiology practice throughout the world. This activity is effective at the Haute Correze Hospital Center since more than 20 years...Background: Pacemaker implantation is a very old activity which has revolutionized the cardiology practice throughout the world. This activity is effective at the Haute Correze Hospital Center since more than 20 years. Due to progress in this area, and the increasing request within this center located at the outskirts of town, we set out to evaluate our pacemaker activity in general and more specifically to assess the post-procedural complications in our series patients. Methodology: This was a retrospective longitudinal study. Data were recorded for period of 90 months from 27/05/2016 to 19/11/2023. This data collection was possible via a specific register completed by computerized patient data from the SillageTM software. All files of patients implanted with single or dual chamber pacemakers were included, generator replacements, upgrading procedures and addition of leads were excluded. The sampling was non-probabilistic, consecutive and non-exhaustive. Statistical analysis was carried out using the Excel 2019 spreadsheet and SPSS version 23 software. The quantitative variables were presented as mean ± standard deviation, the qualitative data as proportions. Results: A total of 303 first-time pacemaker’s implantations were carried out during the study period (rate of 40 per year). The average age in the population was 79.7 ± 9.4 years (44 - 99 years) with a male predominance of 63.7% (n = 193). Atrioventricular block (2nd and 3rd degree) was the main indication for pacemaker implantation in 42.9% of cases (n = 130). Patients were most often implanted with a dual-chamber pacemaker (57.7%, n = 175). The approach was most often cephalic in 72.6% of cases (n = 220), followed by the subclavian access in 27.4% of cases (n = 84). The average fluoroscopy time was 7.9 min ± 2.4 (1 - 43). The average irradiation dose in gray/cm2 was 12.4 ± 9.3 (0.22 - 117.5). The average length of hospitalization was 7 ± 4 (2 - 26) days. The overall complication rate at one year was 12.9% (n = 39). These complications are distributed as follows: Leads dislodgement in 8.2% (n = 25), hematoma 3.6% (n = 11) all without clinical consequences, pneumothorax 0.7% (n = 2), both cases of pneumothorax did not require specific care, infection (superficial) in 0.3% (n = 1). Leads dislodgement occurred after a median time of 18 days (IQR: 3 - 36). The earliest dislodgement was observed on D0 and the latest on D207. No serious complications were recorded. The average atrial threshold at implantation/first control/last follow-up was 0.7/1.3/0.8 V, respectively. The average ventricular threshold at implantation/first control/last follow-up was 0.5/1.08/0.87 V, respectively. The average atrial detection at implantation/first control/last follow-up was 3.2/2.3/ 2.05 mv, respectively. The average ventricular detection at implantation/first control/last follow-up was 10.3/11.03/10.8 mv. The average atrial impedance at implantation/first control/last follow-up was 610/457/457 ohms. The average ventricular impedance at implantation/first control/last follow-up was 754/547/563 ohms. Conclusion: Pacemaker implantation is safe at the Haute Correze Hospital Center with a relatively low rate of complications, in this case an almost zero major infection and no serious hematoma. The peripheral hospital should remain a focal point of this activity in order to respond more quickly to the needs of the populations.展开更多
Aim: To explore the application effect of external diaphragm pacemaker combined with active respiratory circulation technology in pulmonary rehabilitation of perioperative lung cancer patients. Methods: A total of 98 ...Aim: To explore the application effect of external diaphragm pacemaker combined with active respiratory circulation technology in pulmonary rehabilitation of perioperative lung cancer patients. Methods: A total of 98 lung cancer patients admitted to our hospital from April 2020 to November 2021 were selected as the observation objects, and then divided into a control group and an observation group using the random number table method, with 49 cases in each group. The control group received routine admission guidance and active respiratory circulation training, while the observation group was supplemented with external diaphragm pacemaker on the basis of the control group. The intervention effect was evaluated by blood gas indicators, pulmonary function indicators, diaphragm function indicators, sputum comfort degree, and activity tolerance indicators before and after intervention. Results: Before intervention, there were no significant differences in blood gas analysis indicators, pulmonary function indicators, diaphragm function indicators, sputum comfort degree, and activity tolerance indicators between the two groups (P > 0.05). After intervention, the improvement degree of the above indicators in the observation group was higher than that in the control group (P < 0.05). Conclusions: The application of external diaphragm pacemaker combined with active respiratory circulation technology in pulmonary rehabilitation of perioperative lung cancer patients is significant, which can effectively improve the pulmonary function, blood gas function, and diaphragm function of lung cancer patients after surgery, and improve the activities of daily living and quality of life of patients.展开更多
BACKGROUND Pacemaker lead-induced heart perforation is a rare but life-threatening complication of pacemaker implantation,and timely diagnosis remains a challenge for clinicians.Here,we report a case of pacemaker lead...BACKGROUND Pacemaker lead-induced heart perforation is a rare but life-threatening complication of pacemaker implantation,and timely diagnosis remains a challenge for clinicians.Here,we report a case of pacemaker lead-induced cardiac perforation rapidly diagnosed by a“bow-and-arrow”sign on point-of-care ultrasound(POCUS).CASE SUMMARY A 74-year-old Chinese woman who had undergone permanent pacemaker implantation 26 d before suddenly developed severe dyspnea,chest pain,and hypotension.The patient had received emergency laparotomy for an incarcerated groin hernia and was transferred to the intensive care unit 6 d before.Computed tomography was not available due to unstable hemodynamic status,so POCUS was performed at the bedside and revealed severe pericardial effusion and cardiac tamponade.Subsequent pericardiocentesis yielded a large volume of bloody pericardial fluid.Further POCUS by an ultrasonographist revealed a unique“bow-and-arrow”sign indicating right ventricular(RV)apex perforation by the pacemaker lead,which facilitated the rapid diagnosis of lead perforation.Given the persistent drainage of pericardial bleeding,urgent off-pump open chest surgery was performed to repair the perforation.However,the patient died of shock and multiple organ dysfunction syndrome within 24 h post-surgery.In addition,we also performed a literature review on the sonographic features of RV apex perforation by lead.CONCLUSION POCUS enables the early diagnosis of pacemaker lead perforation at the bedside.A step-wise ultrasonographic approach and the“bow-and-arrow”sign on POCUS are helpful for rapid diagnosis of lead perforation.展开更多
BACKGROUND Dextroversion is defined as the presence of dextrocardia with situs solitus,dextroloop ventricles,and normally related great arteries.Dextrocardia can pose technical challenges when interventional treatment...BACKGROUND Dextroversion is defined as the presence of dextrocardia with situs solitus,dextroloop ventricles,and normally related great arteries.Dextrocardia can pose technical challenges when interventional treatments are required.However,the challenges posed by dextroversion can be amplified due to the disruption of typical anatomical relationships,the unpredictable positioning and boundaries of cardiac structures resulting from the shift,and the pathological processes influencing rotation.CASE SUMMARY A 73-year-old woman with cardiac dextroversion suffered from a recurrence of atrial fibrillation after her radiofrequency catheter ablation and Despite the cessation of antiarrhythmic medications,there were episodes of sinus pauses and symptomatic bradycardia,with heart rates dropping as low as 28 beats per minute.CONCLUSION Dextroversion makes the implantation of leadless pacemakers more challenging,and appropriate adjustments in fluoroscope angles may be crucial for intracardiac operations.Additionally,when advancing delivery systems,attention should be paid to rotational direction during valve-crossing procedures;changes in the perspective of posture angle between normal cardiac position and dextroversion can serve as references.展开更多
BACKGROUND Atrioventricular block requiring permanent pacemaker(PPM)implantation is an important complication of transcatheter aortic valve replacement(TAVR).Application of machine learning could potentially be used t...BACKGROUND Atrioventricular block requiring permanent pacemaker(PPM)implantation is an important complication of transcatheter aortic valve replacement(TAVR).Application of machine learning could potentially be used to predict preprocedural risk for PPM.AIM To apply machine learning to be used to predict pre-procedural risk for PPM.METHODS A retrospective study of 1200 patients who underwent TAVR(January 2014-December 2017)was performed.964 patients without prior PPM were included for a 30-d analysis and 657 patients without PPM requirement through 30 d were included for a 1-year analysis.After the exclusion of variables with near-zero variance or≥50%missing data,167 variables were included in the random forest gradient boosting algorithm(GBM)optimized using 5-fold cross-validations repeated 10 times.The receiver operator curve(ROC)for the GBM model and PPM risk score models were calculated to predict the risk of PPM at 30 d and 1 year.RESULTS Of 964 patients included in the 30-d analysis without prior PPM,19.6%required PPM post-TAVR.The mean age of patients was 80.9±8.7 years.42.1%were female.Of 657 patients included in the 1-year analysis,the mean age of the patients was 80.7±8.2.Of those,42.6%of patients were female and 26.7%required PPM at 1-year post-TAVR.The area under ROC to predict 30-d and 1-year risk of PPM for the GBM model(0.66 and 0.72)was superior to that of the PPM risk score(0.55 and 0.54)with a P value<0.001.CONCLUSION The GBM model has good discrimination and calibration in identifying patients at high risk of PPM post-TAVR.展开更多
BACKGROUND Bradyarrhythmias are typically treated with permanent pacemakers(PM). The elimination of bradyarrhythmia by PM implantation improves the patient’s quality of life and prognosis, but it can also result in a...BACKGROUND Bradyarrhythmias are typically treated with permanent pacemakers(PM). The elimination of bradyarrhythmia by PM implantation improves the patient’s quality of life and prognosis, but it can also result in a number of sequalae. It is still unclear how PM implantation affects the hemostasis system’s parameters and how such parameters relate to different consequences after PM placement.AIM To assess the blood coagulation factor activity in PM patients throughout the perioperative period.METHODS Patients treated in the Department of Surgical Therapy of Cardiac Arrhythmias and Pacing at the Ryazan State "Regional Clinical Cardiology Dispensary" from April 2020 to December 2021 were included in the study. Before surgery, 7 and 30 d after PM placement, peripheral venous blood samples were withdrawn to measure the level of blood coagulation factor Ⅰ(FⅠ) and the activity of blood coagulation factors Ⅱ(FⅡ), Ⅴ(FⅤ), Ⅶ(FⅦ), Ⅷ(FⅧ), ⅸ(Fⅸ), ⅹ(Fⅹ), Ⅺ(FⅪ), Ⅻ(FⅫ). We used an automatic coagulometer Sysmex CA 660(Sysmex Europe, Germany) and reagents from Siemens(Siemens Healthcare Diagnostics Products GmbH, Germany).RESULTS The study included 146 patients. The activity of factors FⅤ [147.7(102.1-247.55)% vs 103.85(60-161.6)% vs 81.8(67.15-130.65)%, P = 0.002], FⅧ [80.4(60.15-106.25)% vs 70.3(48.5-89.1)% vs 63.7(41.6-88.25)%, P = 0.039], Fⅸ [86.2(70.75-102.95)% vs 75.4(59.2-88.3)% vs 73.9(56.45-93.05)%, P = 0.014], Fⅹ [188.9(99.3-308.18)% vs 158.9(83.3-230)% vs 127.2(95.25-209.35)%, P = 0.022], FⅪ [82.6(63.9-103.6)% vs 69.75(53.8-97.6)% vs 67.3(54.25-98.05)%, P = 0.002], FⅫ [87.6(67.15-102.3)% vs 78.9(63.4-97.05)% vs 81.2(62.15-97.4)%, P < 0.001] decreased at 7 and 30 d after surgery;FⅡ activity [157.9(109.7-245.25)% vs 130(86.8-192.5)% vs 144.8(103.31-185.6)%, P = 0.021] decreased at 7 d and increased at 30 d postoperatively. There were no statistically significant changes in the FVII activity within 30 d after PM placement [182.2(85.1-344.8)% vs 157.2(99.1-259)% vs 108.9(74.9-219.8)%, P = 0.128]. Subgroup analysis revealed similar changes only in patients on anticoagulant therapy. FⅫ activity decreased in patients on antiplatelet therapy [82(65.8-101.9)% vs 79.9(63.3-97.1)% vs 89.7(75.7-102.5)%, P = 0.01] 7 d after surgery, returning to baseline values at 30 d postoperatively.CONCLUSION PM placement and anticoagulant therapy were associated with decreased activity of clotting factors FⅤ, FⅧ, Fⅸ, Fⅹ, FⅪ, FⅫ in the postoperative period. FⅧ activity did not decrease within 30 d after PM placement, which may indicate endothelial injury caused by lead placement.展开更多
BACKGROUND Although superior vena cava(SVC)syndrome has also been reported as a late complication of pacemaker(PM)implantation,acute onset of SVC syndrome caused by disdialysis syndrome in patients with PM implantatio...BACKGROUND Although superior vena cava(SVC)syndrome has also been reported as a late complication of pacemaker(PM)implantation,acute onset of SVC syndrome caused by disdialysis syndrome in patients with PM implantation is very rare.There are no specific therapies or guidelines.CASE SUMMARY A 96-year-old woman receiving dialysis was implanted with a PM due to sick sinus syndrome.She was referred to our facility for chest discomfort experienced during dialysis.Upon examination,unilateral pleural effusion on the right side was cloudy with a foul odour.The patient was diagnosed with pyothorax and treated with antibiotics.After the effusion was reduced,it gradually reaggravated and remained cloudy.In this case,SVC syndrome,which is generally considered a late complication after PM implantation,rapidly developed following the bacteraemia,resulting in impaired venous return,chylothorax,and disdialysis syndrome.After catheter intervention for SVC stenosis,the patient’s symptoms promptly improved.The patient has been recurrence-free for a year.CONCLUSION Acute SVC syndrome can cause dysdialysis in PM-implanted patients.Catheter intervention alone has improved this condition for a traceable period.展开更多
Research objective: To study a clinical case that had a complication of subclavian artery bleeding during permanent pacemaker implantation process. Subject and Method: Clinical case report and literature review. Study...Research objective: To study a clinical case that had a complication of subclavian artery bleeding during permanent pacemaker implantation process. Subject and Method: Clinical case report and literature review. Study of a patient had an indication for permanent pacemaker implantation who had complication of subclavian artery bleeding during the procedure. Result: An 84-year-old female patient was admitted to the hospital because of fainting spells with chest pain, on the background of dangerous complex arrhythmias and ischemic heart disease, and was prescribed a pacemaker for this patient. The patient had complication occurred during the procedure, which left subclavian artery bleeding was detected and treated promptly, a cardiac pacemaker was implanted on the right side of the chest, and the patient had a successful endovascular stent cover in the left subclavian artery. Conclude: Subclavian artery bleeding is a rare complication in the procedure of permanent pacemaker implantation, but it can still occur and requires quick detection and timely treatment, needs to be successful in cardiac pacemaker placement and subclavian artery drug-eluting stent cover placement intervention. Individualized patient risk assessment is needed;appropriate and standardized intervention techniques and experience can reduce the occurrence of this variable.展开更多
Objectives:We aim to compare the major complications between leadless pacemakers and traditional pacemakers.Background:Leadless pacemakers,which are increasingly used in clinical practice,have several advantages compa...Objectives:We aim to compare the major complications between leadless pacemakers and traditional pacemakers.Background:Leadless pacemakers,which are increasingly used in clinical practice,have several advantages compared with traditional pacemakers in avoiding pocket-and lead-related complications.However,the clinical effect of leadless pacemakers remains controversial.Methods:PubMed,Embase,the Cochrane Central Register of Controlled Trials(CENTRAL),the CNKI database,and the Wanfang database were searched from July 2013 to December 2019.Studies comparing leadless pacemakers and traditional pacemakers were included.The primary end point was major complications.The secondary end points were cardiac perforation/pericardial effusion,device revision or extraction,loss of device function,and death.Results:Six studies fulfi lled the inclusion criteria.Only four of the six studies reported data on major complications.Leadless pacemakers were associated with a lower incidence of major complications(risk ratio 0.33,95%confi dence interval 0.25–0.44,P<0.00001,I²=49%).We extracted data on cardiac perforation/pericardial effusion,device revision or extraction,loss of device function,and death from six studies.Our meta-analysis showed that leadless pacemakers have a higher risk of cardiac perforation or pericardial effusion(risk ratio 4.28,95%confi dence interval 1.66–11.08,P=0.003,I²=0%).No statistically signifi cant differences were found for mortality,device revision or extraction,and loss of device function.Conclusion:Compared with traditional pacemakers,leadless pacemakers have a signifi cantly decreased risk of major complications,but have a higher risk of cardiac perforation or pericardial effusion.展开更多
Objective To retrospectively identify risk factors and the prognosis for new-onset atrial fibrillation (AF)after implantation of dual-chamber pacemakers in elderly patients.Methods Consecutive patients aged >65year...Objective To retrospectively identify risk factors and the prognosis for new-onset atrial fibrillation (AF)after implantation of dual-chamber pacemakers in elderly patients.Methods Consecutive patients aged >65years who underwent their first implantation of a dual-chamber permanent pacemaker in Beijing Anzhen Hospital from October 2013to May 2016were enrolled.Their complete program- ming and follow-up data were recorded.Follow-up end points included new-onset AF and major adverse cardiovascular and cerebrovascular events.Restdts Altogether,322patients were enrolled,with new-onset AF observed in 79(24.5%)during their follow-up.Multivariable analysis identified four independent predictors of new-onset AF in elderly patients after pacemaker implantation:hypertension (HR =3.040, 95%CI:1.09-3.05,P =0.00),age (HR =1.966,95%CI:1.57-3.68,P =0.01);left atrial enlargement (HR =1.645,95%CI:1.05-1.25,P = 0.03);high ventricular pacing rate (HR =1.137,95%CI:1.01-1.06,P =0.01).Univariable analysis indicated that the CHA2DS2-VASc score was also a risk factor for AF (HR =1.368,95%CI:1.178-1.589,P =0.002),whereas multivariable regression analysis did not. Kaplan-Meier survival analysis showed that the risk for ischemic stroke was significantly higher in the new-onset AF group than in the non-AF group (P <0.05).Conclusion Hypertension,age,left atrial enlargement,and high ventricular pacing rate were independent predictors of new-onset AF in elderly patients after implantation of a permanent pacemaker.New-onset AF increased the risk for ischemic stroke.展开更多
Objective To assess the prevalence of the bleeding complications in pacemaker implanted patients receiving different antiplatelet regimens, and the influence of each regimen on hospital stays after device implantation...Objective To assess the prevalence of the bleeding complications in pacemaker implanted patients receiving different antiplatelet regimens, and the influence of each regimen on hospital stays after device implantation. Methods We prospectively enrolled 364 patients receiving the cardiac rhythm device implantations in Fuwai Hospital from July 2012 to December 2013. Bleeding complications including pocket hematoma, hemothorax, cardiac tamponade and blood transfusion requirement were measured as endpoints. Post operation hospital stay was also included in the endpoints. Results Bleeding complications were detected in 15 patients (14 with hematoma, one with hemothorax) out of all 364 patients (4.12%). Dual antiplatelet therapy (DAT) significantly increased hematoma (19.3%) compared with aspi- fin treatment (ASA) (3.2%, P = 0.001) and no antiplatelet therapy (1.9%, P 〈 0.001). There was no significant difference in incidence of pocket hematoma between the ASA group and the control group (P = 0.45). The post procedure hospital stay was longer in DAT group (5.45 ± 2.01 days) compared to those in the ASA group (3.65 ± 1.37 days, P 〈 0.05) or control group (3.99 ± 2.27 days, P 〈 0.05). Pocket hema- toma was considered an independent predictor of hospital stay prolongation (OR: 5.26; 95% CI: 1.56-16.64; P = 0.007). Conclusions Among the Chinese patients undergoing device implantation in this study, the use of dual antiplatelet agents significantly increased the risk of pocket hematoma complications and led to a longer hospital stay. Use of aspirin alone did not increase the risk.展开更多
AIM To investigate the effects of a water extract of Hwangryunhaedok-tang(HHTE) on the pacemaker potentials of mouse interstitial cells of Cajal(ICCs).METHODS We dissociated ICCs from small intestines and cultured. IC...AIM To investigate the effects of a water extract of Hwangryunhaedok-tang(HHTE) on the pacemaker potentials of mouse interstitial cells of Cajal(ICCs).METHODS We dissociated ICCs from small intestines and cultured. ICCs were immunologically identified using an antic-kit antibody. We used the whole-cell patch-clamp configuration to record the pacemaker potentials generated by cultured ICCs under the current clamp mode(I = 0). All experiments were performed at 30 ℃-32 ℃RESULTS HHTE dose-dependently depolarized ICC pacemaker potentials. Pretreatment with a 5-HT_3 receptor anta-gonist(Y25130) or a 5-HT_4 receptor antagonist(RS39604) blocked HHTE-induced pacemaker potential depolarizations, whereas pretreatment with a 5-HT7 receptor antagonist(SB269970) did not. Intracellular GDPβS inhibited HHTE-induced pacemaker potential depolarization and pretreatment with a Ca^(2+)-free solution or thapsigargin abolished the pacemaker potentials. In the presence of a Ca^(2+)-free solution or thapsigargin, HHTE did not depolarize ICC pacemaker potentials. In addition, HHTE-induced pacemaker potential depolarization was unaffected by a PKC inhibitor(calphostin C) or a Rho kinase inhibitor(Y27632). Of the four ingredients of HHT, Coptidis Rhizoma and Gardeniae Fructus more effectively inhibited pacemaker potential depolarization.CONCLUSION These results suggest that HHTE dose-dependently depolarizes ICC pacemaker potentials through 5-HT_3 and 5-HT_4 receptors via external and internal Ca^(2+) regulation and via G protein-, PKC-and Rho kinase-independent pathways.展开更多
AIM:To determine if there were any interactions between cardiac devices and small bowel capsules secondary to electromagnetic interference (EMI) in patients who have undergone small bowel capsule endoscopy (SBCE).METH...AIM:To determine if there were any interactions between cardiac devices and small bowel capsules secondary to electromagnetic interference (EMI) in patients who have undergone small bowel capsule endoscopy (SBCE).METHODS:Authors conducted a chart review of 20 patients with a cardiac pacemaker (CP) or implantable cardioverter defibrillator (ICD) who underwent continuous electrocardiographic monitoring during their SBCE from 2003-2008.authors searched for unexplained electrocardiogram (ECG) findings,changes in CP andICD set parameters,any abnormality in transmitted capsule data,and adverse clinical events.RESULTS:There were no adverse events or hemodynamically significant arrhythmias reported.CP and ICD set parameters were preserved.The majority of ECG abnormalities were also found in pre-or post-SBCE ECG tracings and the CP behavior during arrhythmias appeared appropriate.Two patients seemed to have episodes of undersensing by the CP.However,similar findings were documented in ECGs taken outside the time frame of the SBCE.One patient was observed to have a low signal encountered from the capsule resulting in lack of localization,but no images were lost.CONCLUSION:Capsule-induced EMI remains a possibility but is unlikely to be clinically important.CPinduced interference of SBCE is also possible,but is infrequent and does not result in loss of images transmitted by the capsule.展开更多
To investigate the mechanisms of microwave induced pacemaker cell injuries, Wistar rats and the primary pacemaker cells of newborn Wistar rats were exposed to microwave at average power density of 50 mW/cm2. Slower sp...To investigate the mechanisms of microwave induced pacemaker cell injuries, Wistar rats and the primary pacemaker cells of newborn Wistar rats were exposed to microwave at average power density of 50 mW/cm2. Slower spontaneous beating rate, intercellular Ca2+ aggregation and cell membrane perforation were detected immediately after the exposure. Moreover, hyperpolarizationactivated cyclic nucleotide-gated cation channel 4 (HCN4) was down-regulated immediately after the exposure and up-regulated at 12 h after the exposure. In the sinoatrial node (SAN) of the rats,展开更多
BACKGROUND: This study aims to investigate whether small balloon aortic valvuloplasty(BAV) reduces the need for permanent pacemaker implantation (PPMI) after transcatheter aortic valveimplantation (TAVI).METHODS: This...BACKGROUND: This study aims to investigate whether small balloon aortic valvuloplasty(BAV) reduces the need for permanent pacemaker implantation (PPMI) after transcatheter aortic valveimplantation (TAVI).METHODS: This was a retrospective analysis using data from our local TAVI database. SmallBAV was defined as a small balloon size (=18 mm) pre-dilatation. Normal BAV was defined as aballoon size >18 mm. The primary endpoint was the incidence of new PPMI.RESULTS: Of 99 consecutive TAVI patients, five patients were excluded due to pre-existingpermanent pacemaker. Patients in the small BAV group (n=57) had a signifi cantly lower PPMI ratecompared with the normal BAV group (n=37) (3.5% vs. 18.9%, P=0.026). Moderate or severe aorticvalve regurgitation post-procedure was similar between the small BAV and normal BAV groups (5.3%vs. 8.1%, P=0.480);likewise, the mean aortic gradient post-procedure did not differ significantly(11.5±5.2 mmHg vs. 12.2±7.3 mmHg, 1 mmHg=0.133 kPa, P=0.580) between the groups. Devicesuccess rates were also similar (94.7% vs. 91.8%, P=0.680). In multivariable analysis, small BAV(P=0.027), the ratio of prosthesis diameter to annulus diameter (P=0.048), and mean aortic gradientby echo in the basement (P=0.021) were independent predictors of PPMI.CONCLUSIONS: The small BAV strategy is associated with a low rate of permanentpacemaker implantation after transcatheter self-expanding valve implantation in this single-centerobservational study.展开更多
基金supported by 2023 Liaoning Provincial Department of Education Basic Research Project (General Project)(JYTMS20230815)。
文摘To solve the low power transfer efficiency and magnetic field leakage problems of cardiac pacemaker wireless powering, we proposed a wireless power supply system suitable for implanted cardiac pacemaker based on mu-negative(MNG) and mu-nearzero(MNZ) metamaterials. First, a hybrid metamaterial consisted of central MNG unit for magnetic field concentration and surrounding MNZ units for magnetic leakage shielding was established by theoretical calculation. Afterwards, the magnetic field distribution of wireless power supply system with MNG-MNZ metamaterial slab was acquired via finite element simulation and verified to be better than the distribution with conventional MNG slab deployed. Finally, an experimental platform of wireless power supply system was established with which power transfer experiment and system temperature rise experiment were conducted.Simulation and experimental results showed that the power transfer efficiency was improved from 44.44%,19.42%, 8.63% and 6.19% to 55.77%, 62.39%, 20.81%and 14.52% at 9.6 mm, 20 mm, 30 mm and 50 mm,respectively. The maximum SAR acquired by SAR simulation under human body environment was-7.14 dbm and maximum reduction of the magnetic field strength around the receiving coil was 2.82 A/m. The maximum temperature rise during 30min charging test was 3.85℃,and the safety requirements of human bodies were met.
文摘Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized controlled trials has resulted in an exponential rise in the use of TAVR even in the low-risk patients.However,this is not without challenges.Need for permanent pacemaker(PPM)post-TAVR remains the most frequent and clinically relevant challenge.Naturally,identifying risk factors which predispose an individual to develop high grade conduction block post-TAVR is important.Various demographic factors,electrocardiographic features,anatomic factors and procedural characteristics have all been linked to the development of advanced conduction block and need for PPM following TAVR.Amongst these electrophysiological variables,most notably a prolonged QRS>120 ms regardless of the type of conduction block seems to be one of the strongest predictors on logistic regression models.The index study by Nwaedozie et al highlights that patients requiring PPM post-TAVR had higher odds of having a baseline QRS>120 ms and were more likely to be having diabetes mellitus that those who did not require PPM.
文摘In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR.
文摘Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have at least as much impact on the final need for a permanent pacemaker and potentially on the pacing rate.In this regard,long-term follow-up and understanding of the impact of long-term stimulation is of utmost importance.
文摘Background: Pacemaker implantation is a very old activity which has revolutionized the cardiology practice throughout the world. This activity is effective at the Haute Correze Hospital Center since more than 20 years. Due to progress in this area, and the increasing request within this center located at the outskirts of town, we set out to evaluate our pacemaker activity in general and more specifically to assess the post-procedural complications in our series patients. Methodology: This was a retrospective longitudinal study. Data were recorded for period of 90 months from 27/05/2016 to 19/11/2023. This data collection was possible via a specific register completed by computerized patient data from the SillageTM software. All files of patients implanted with single or dual chamber pacemakers were included, generator replacements, upgrading procedures and addition of leads were excluded. The sampling was non-probabilistic, consecutive and non-exhaustive. Statistical analysis was carried out using the Excel 2019 spreadsheet and SPSS version 23 software. The quantitative variables were presented as mean ± standard deviation, the qualitative data as proportions. Results: A total of 303 first-time pacemaker’s implantations were carried out during the study period (rate of 40 per year). The average age in the population was 79.7 ± 9.4 years (44 - 99 years) with a male predominance of 63.7% (n = 193). Atrioventricular block (2nd and 3rd degree) was the main indication for pacemaker implantation in 42.9% of cases (n = 130). Patients were most often implanted with a dual-chamber pacemaker (57.7%, n = 175). The approach was most often cephalic in 72.6% of cases (n = 220), followed by the subclavian access in 27.4% of cases (n = 84). The average fluoroscopy time was 7.9 min ± 2.4 (1 - 43). The average irradiation dose in gray/cm2 was 12.4 ± 9.3 (0.22 - 117.5). The average length of hospitalization was 7 ± 4 (2 - 26) days. The overall complication rate at one year was 12.9% (n = 39). These complications are distributed as follows: Leads dislodgement in 8.2% (n = 25), hematoma 3.6% (n = 11) all without clinical consequences, pneumothorax 0.7% (n = 2), both cases of pneumothorax did not require specific care, infection (superficial) in 0.3% (n = 1). Leads dislodgement occurred after a median time of 18 days (IQR: 3 - 36). The earliest dislodgement was observed on D0 and the latest on D207. No serious complications were recorded. The average atrial threshold at implantation/first control/last follow-up was 0.7/1.3/0.8 V, respectively. The average ventricular threshold at implantation/first control/last follow-up was 0.5/1.08/0.87 V, respectively. The average atrial detection at implantation/first control/last follow-up was 3.2/2.3/ 2.05 mv, respectively. The average ventricular detection at implantation/first control/last follow-up was 10.3/11.03/10.8 mv. The average atrial impedance at implantation/first control/last follow-up was 610/457/457 ohms. The average ventricular impedance at implantation/first control/last follow-up was 754/547/563 ohms. Conclusion: Pacemaker implantation is safe at the Haute Correze Hospital Center with a relatively low rate of complications, in this case an almost zero major infection and no serious hematoma. The peripheral hospital should remain a focal point of this activity in order to respond more quickly to the needs of the populations.
文摘Aim: To explore the application effect of external diaphragm pacemaker combined with active respiratory circulation technology in pulmonary rehabilitation of perioperative lung cancer patients. Methods: A total of 98 lung cancer patients admitted to our hospital from April 2020 to November 2021 were selected as the observation objects, and then divided into a control group and an observation group using the random number table method, with 49 cases in each group. The control group received routine admission guidance and active respiratory circulation training, while the observation group was supplemented with external diaphragm pacemaker on the basis of the control group. The intervention effect was evaluated by blood gas indicators, pulmonary function indicators, diaphragm function indicators, sputum comfort degree, and activity tolerance indicators before and after intervention. Results: Before intervention, there were no significant differences in blood gas analysis indicators, pulmonary function indicators, diaphragm function indicators, sputum comfort degree, and activity tolerance indicators between the two groups (P > 0.05). After intervention, the improvement degree of the above indicators in the observation group was higher than that in the control group (P < 0.05). Conclusions: The application of external diaphragm pacemaker combined with active respiratory circulation technology in pulmonary rehabilitation of perioperative lung cancer patients is significant, which can effectively improve the pulmonary function, blood gas function, and diaphragm function of lung cancer patients after surgery, and improve the activities of daily living and quality of life of patients.
基金Supported by Foundation of Guizhou Science and Technology Department,No.QIANKEHEZHICHEN[2022]YIBAN 179National Natural Science Foundation of China,No.82160370Guizhou Education Department,No.Qian Jiao He KY Zi[2018]239.
文摘BACKGROUND Pacemaker lead-induced heart perforation is a rare but life-threatening complication of pacemaker implantation,and timely diagnosis remains a challenge for clinicians.Here,we report a case of pacemaker lead-induced cardiac perforation rapidly diagnosed by a“bow-and-arrow”sign on point-of-care ultrasound(POCUS).CASE SUMMARY A 74-year-old Chinese woman who had undergone permanent pacemaker implantation 26 d before suddenly developed severe dyspnea,chest pain,and hypotension.The patient had received emergency laparotomy for an incarcerated groin hernia and was transferred to the intensive care unit 6 d before.Computed tomography was not available due to unstable hemodynamic status,so POCUS was performed at the bedside and revealed severe pericardial effusion and cardiac tamponade.Subsequent pericardiocentesis yielded a large volume of bloody pericardial fluid.Further POCUS by an ultrasonographist revealed a unique“bow-and-arrow”sign indicating right ventricular(RV)apex perforation by the pacemaker lead,which facilitated the rapid diagnosis of lead perforation.Given the persistent drainage of pericardial bleeding,urgent off-pump open chest surgery was performed to repair the perforation.However,the patient died of shock and multiple organ dysfunction syndrome within 24 h post-surgery.In addition,we also performed a literature review on the sonographic features of RV apex perforation by lead.CONCLUSION POCUS enables the early diagnosis of pacemaker lead perforation at the bedside.A step-wise ultrasonographic approach and the“bow-and-arrow”sign on POCUS are helpful for rapid diagnosis of lead perforation.
基金Shanxi Provincial Health Commission“Four batch”Science and Technology Innovation Project of Medical Development,No.2021XM45Natural Science Foundation of Shanxi Province,No.20210302123346+1 种基金Scientific Research Incentive Fund of Shanxi Cardiovascular Hospital,No.XYS20220205Traditional Chinese Medicine research project of Shanxi Province,No.2023ZYYA028.
文摘BACKGROUND Dextroversion is defined as the presence of dextrocardia with situs solitus,dextroloop ventricles,and normally related great arteries.Dextrocardia can pose technical challenges when interventional treatments are required.However,the challenges posed by dextroversion can be amplified due to the disruption of typical anatomical relationships,the unpredictable positioning and boundaries of cardiac structures resulting from the shift,and the pathological processes influencing rotation.CASE SUMMARY A 73-year-old woman with cardiac dextroversion suffered from a recurrence of atrial fibrillation after her radiofrequency catheter ablation and Despite the cessation of antiarrhythmic medications,there were episodes of sinus pauses and symptomatic bradycardia,with heart rates dropping as low as 28 beats per minute.CONCLUSION Dextroversion makes the implantation of leadless pacemakers more challenging,and appropriate adjustments in fluoroscope angles may be crucial for intracardiac operations.Additionally,when advancing delivery systems,attention should be paid to rotational direction during valve-crossing procedures;changes in the perspective of posture angle between normal cardiac position and dextroversion can serve as references.
基金funded by Mayo Clinic Arizona Cardiovascular Clinical Research Center (MCA CV CRC)
文摘BACKGROUND Atrioventricular block requiring permanent pacemaker(PPM)implantation is an important complication of transcatheter aortic valve replacement(TAVR).Application of machine learning could potentially be used to predict preprocedural risk for PPM.AIM To apply machine learning to be used to predict pre-procedural risk for PPM.METHODS A retrospective study of 1200 patients who underwent TAVR(January 2014-December 2017)was performed.964 patients without prior PPM were included for a 30-d analysis and 657 patients without PPM requirement through 30 d were included for a 1-year analysis.After the exclusion of variables with near-zero variance or≥50%missing data,167 variables were included in the random forest gradient boosting algorithm(GBM)optimized using 5-fold cross-validations repeated 10 times.The receiver operator curve(ROC)for the GBM model and PPM risk score models were calculated to predict the risk of PPM at 30 d and 1 year.RESULTS Of 964 patients included in the 30-d analysis without prior PPM,19.6%required PPM post-TAVR.The mean age of patients was 80.9±8.7 years.42.1%were female.Of 657 patients included in the 1-year analysis,the mean age of the patients was 80.7±8.2.Of those,42.6%of patients were female and 26.7%required PPM at 1-year post-TAVR.The area under ROC to predict 30-d and 1-year risk of PPM for the GBM model(0.66 and 0.72)was superior to that of the PPM risk score(0.55 and 0.54)with a P value<0.001.CONCLUSION The GBM model has good discrimination and calibration in identifying patients at high risk of PPM post-TAVR.
文摘BACKGROUND Bradyarrhythmias are typically treated with permanent pacemakers(PM). The elimination of bradyarrhythmia by PM implantation improves the patient’s quality of life and prognosis, but it can also result in a number of sequalae. It is still unclear how PM implantation affects the hemostasis system’s parameters and how such parameters relate to different consequences after PM placement.AIM To assess the blood coagulation factor activity in PM patients throughout the perioperative period.METHODS Patients treated in the Department of Surgical Therapy of Cardiac Arrhythmias and Pacing at the Ryazan State "Regional Clinical Cardiology Dispensary" from April 2020 to December 2021 were included in the study. Before surgery, 7 and 30 d after PM placement, peripheral venous blood samples were withdrawn to measure the level of blood coagulation factor Ⅰ(FⅠ) and the activity of blood coagulation factors Ⅱ(FⅡ), Ⅴ(FⅤ), Ⅶ(FⅦ), Ⅷ(FⅧ), ⅸ(Fⅸ), ⅹ(Fⅹ), Ⅺ(FⅪ), Ⅻ(FⅫ). We used an automatic coagulometer Sysmex CA 660(Sysmex Europe, Germany) and reagents from Siemens(Siemens Healthcare Diagnostics Products GmbH, Germany).RESULTS The study included 146 patients. The activity of factors FⅤ [147.7(102.1-247.55)% vs 103.85(60-161.6)% vs 81.8(67.15-130.65)%, P = 0.002], FⅧ [80.4(60.15-106.25)% vs 70.3(48.5-89.1)% vs 63.7(41.6-88.25)%, P = 0.039], Fⅸ [86.2(70.75-102.95)% vs 75.4(59.2-88.3)% vs 73.9(56.45-93.05)%, P = 0.014], Fⅹ [188.9(99.3-308.18)% vs 158.9(83.3-230)% vs 127.2(95.25-209.35)%, P = 0.022], FⅪ [82.6(63.9-103.6)% vs 69.75(53.8-97.6)% vs 67.3(54.25-98.05)%, P = 0.002], FⅫ [87.6(67.15-102.3)% vs 78.9(63.4-97.05)% vs 81.2(62.15-97.4)%, P < 0.001] decreased at 7 and 30 d after surgery;FⅡ activity [157.9(109.7-245.25)% vs 130(86.8-192.5)% vs 144.8(103.31-185.6)%, P = 0.021] decreased at 7 d and increased at 30 d postoperatively. There were no statistically significant changes in the FVII activity within 30 d after PM placement [182.2(85.1-344.8)% vs 157.2(99.1-259)% vs 108.9(74.9-219.8)%, P = 0.128]. Subgroup analysis revealed similar changes only in patients on anticoagulant therapy. FⅫ activity decreased in patients on antiplatelet therapy [82(65.8-101.9)% vs 79.9(63.3-97.1)% vs 89.7(75.7-102.5)%, P = 0.01] 7 d after surgery, returning to baseline values at 30 d postoperatively.CONCLUSION PM placement and anticoagulant therapy were associated with decreased activity of clotting factors FⅤ, FⅧ, Fⅸ, Fⅹ, FⅪ, FⅫ in the postoperative period. FⅧ activity did not decrease within 30 d after PM placement, which may indicate endothelial injury caused by lead placement.
文摘BACKGROUND Although superior vena cava(SVC)syndrome has also been reported as a late complication of pacemaker(PM)implantation,acute onset of SVC syndrome caused by disdialysis syndrome in patients with PM implantation is very rare.There are no specific therapies or guidelines.CASE SUMMARY A 96-year-old woman receiving dialysis was implanted with a PM due to sick sinus syndrome.She was referred to our facility for chest discomfort experienced during dialysis.Upon examination,unilateral pleural effusion on the right side was cloudy with a foul odour.The patient was diagnosed with pyothorax and treated with antibiotics.After the effusion was reduced,it gradually reaggravated and remained cloudy.In this case,SVC syndrome,which is generally considered a late complication after PM implantation,rapidly developed following the bacteraemia,resulting in impaired venous return,chylothorax,and disdialysis syndrome.After catheter intervention for SVC stenosis,the patient’s symptoms promptly improved.The patient has been recurrence-free for a year.CONCLUSION Acute SVC syndrome can cause dysdialysis in PM-implanted patients.Catheter intervention alone has improved this condition for a traceable period.
文摘Research objective: To study a clinical case that had a complication of subclavian artery bleeding during permanent pacemaker implantation process. Subject and Method: Clinical case report and literature review. Study of a patient had an indication for permanent pacemaker implantation who had complication of subclavian artery bleeding during the procedure. Result: An 84-year-old female patient was admitted to the hospital because of fainting spells with chest pain, on the background of dangerous complex arrhythmias and ischemic heart disease, and was prescribed a pacemaker for this patient. The patient had complication occurred during the procedure, which left subclavian artery bleeding was detected and treated promptly, a cardiac pacemaker was implanted on the right side of the chest, and the patient had a successful endovascular stent cover in the left subclavian artery. Conclude: Subclavian artery bleeding is a rare complication in the procedure of permanent pacemaker implantation, but it can still occur and requires quick detection and timely treatment, needs to be successful in cardiac pacemaker placement and subclavian artery drug-eluting stent cover placement intervention. Individualized patient risk assessment is needed;appropriate and standardized intervention techniques and experience can reduce the occurrence of this variable.
文摘Objectives:We aim to compare the major complications between leadless pacemakers and traditional pacemakers.Background:Leadless pacemakers,which are increasingly used in clinical practice,have several advantages compared with traditional pacemakers in avoiding pocket-and lead-related complications.However,the clinical effect of leadless pacemakers remains controversial.Methods:PubMed,Embase,the Cochrane Central Register of Controlled Trials(CENTRAL),the CNKI database,and the Wanfang database were searched from July 2013 to December 2019.Studies comparing leadless pacemakers and traditional pacemakers were included.The primary end point was major complications.The secondary end points were cardiac perforation/pericardial effusion,device revision or extraction,loss of device function,and death.Results:Six studies fulfi lled the inclusion criteria.Only four of the six studies reported data on major complications.Leadless pacemakers were associated with a lower incidence of major complications(risk ratio 0.33,95%confi dence interval 0.25–0.44,P<0.00001,I²=49%).We extracted data on cardiac perforation/pericardial effusion,device revision or extraction,loss of device function,and death from six studies.Our meta-analysis showed that leadless pacemakers have a higher risk of cardiac perforation or pericardial effusion(risk ratio 4.28,95%confi dence interval 1.66–11.08,P=0.003,I²=0%).No statistically signifi cant differences were found for mortality,device revision or extraction,and loss of device function.Conclusion:Compared with traditional pacemakers,leadless pacemakers have a signifi cantly decreased risk of major complications,but have a higher risk of cardiac perforation or pericardial effusion.
文摘Objective To retrospectively identify risk factors and the prognosis for new-onset atrial fibrillation (AF)after implantation of dual-chamber pacemakers in elderly patients.Methods Consecutive patients aged >65years who underwent their first implantation of a dual-chamber permanent pacemaker in Beijing Anzhen Hospital from October 2013to May 2016were enrolled.Their complete program- ming and follow-up data were recorded.Follow-up end points included new-onset AF and major adverse cardiovascular and cerebrovascular events.Restdts Altogether,322patients were enrolled,with new-onset AF observed in 79(24.5%)during their follow-up.Multivariable analysis identified four independent predictors of new-onset AF in elderly patients after pacemaker implantation:hypertension (HR =3.040, 95%CI:1.09-3.05,P =0.00),age (HR =1.966,95%CI:1.57-3.68,P =0.01);left atrial enlargement (HR =1.645,95%CI:1.05-1.25,P = 0.03);high ventricular pacing rate (HR =1.137,95%CI:1.01-1.06,P =0.01).Univariable analysis indicated that the CHA2DS2-VASc score was also a risk factor for AF (HR =1.368,95%CI:1.178-1.589,P =0.002),whereas multivariable regression analysis did not. Kaplan-Meier survival analysis showed that the risk for ischemic stroke was significantly higher in the new-onset AF group than in the non-AF group (P <0.05).Conclusion Hypertension,age,left atrial enlargement,and high ventricular pacing rate were independent predictors of new-onset AF in elderly patients after implantation of a permanent pacemaker.New-onset AF increased the risk for ischemic stroke.
文摘Objective To assess the prevalence of the bleeding complications in pacemaker implanted patients receiving different antiplatelet regimens, and the influence of each regimen on hospital stays after device implantation. Methods We prospectively enrolled 364 patients receiving the cardiac rhythm device implantations in Fuwai Hospital from July 2012 to December 2013. Bleeding complications including pocket hematoma, hemothorax, cardiac tamponade and blood transfusion requirement were measured as endpoints. Post operation hospital stay was also included in the endpoints. Results Bleeding complications were detected in 15 patients (14 with hematoma, one with hemothorax) out of all 364 patients (4.12%). Dual antiplatelet therapy (DAT) significantly increased hematoma (19.3%) compared with aspi- fin treatment (ASA) (3.2%, P = 0.001) and no antiplatelet therapy (1.9%, P 〈 0.001). There was no significant difference in incidence of pocket hematoma between the ASA group and the control group (P = 0.45). The post procedure hospital stay was longer in DAT group (5.45 ± 2.01 days) compared to those in the ASA group (3.65 ± 1.37 days, P 〈 0.05) or control group (3.99 ± 2.27 days, P 〈 0.05). Pocket hema- toma was considered an independent predictor of hospital stay prolongation (OR: 5.26; 95% CI: 1.56-16.64; P = 0.007). Conclusions Among the Chinese patients undergoing device implantation in this study, the use of dual antiplatelet agents significantly increased the risk of pocket hematoma complications and led to a longer hospital stay. Use of aspirin alone did not increase the risk.
基金Supported by the National Research Foundation of Korea Grant funded by the Korea Government(MSIP),No.2014R1A5A2009936
文摘AIM To investigate the effects of a water extract of Hwangryunhaedok-tang(HHTE) on the pacemaker potentials of mouse interstitial cells of Cajal(ICCs).METHODS We dissociated ICCs from small intestines and cultured. ICCs were immunologically identified using an antic-kit antibody. We used the whole-cell patch-clamp configuration to record the pacemaker potentials generated by cultured ICCs under the current clamp mode(I = 0). All experiments were performed at 30 ℃-32 ℃RESULTS HHTE dose-dependently depolarized ICC pacemaker potentials. Pretreatment with a 5-HT_3 receptor anta-gonist(Y25130) or a 5-HT_4 receptor antagonist(RS39604) blocked HHTE-induced pacemaker potential depolarizations, whereas pretreatment with a 5-HT7 receptor antagonist(SB269970) did not. Intracellular GDPβS inhibited HHTE-induced pacemaker potential depolarization and pretreatment with a Ca^(2+)-free solution or thapsigargin abolished the pacemaker potentials. In the presence of a Ca^(2+)-free solution or thapsigargin, HHTE did not depolarize ICC pacemaker potentials. In addition, HHTE-induced pacemaker potential depolarization was unaffected by a PKC inhibitor(calphostin C) or a Rho kinase inhibitor(Y27632). Of the four ingredients of HHT, Coptidis Rhizoma and Gardeniae Fructus more effectively inhibited pacemaker potential depolarization.CONCLUSION These results suggest that HHTE dose-dependently depolarizes ICC pacemaker potentials through 5-HT_3 and 5-HT_4 receptors via external and internal Ca^(2+) regulation and via G protein-, PKC-and Rho kinase-independent pathways.
文摘AIM:To determine if there were any interactions between cardiac devices and small bowel capsules secondary to electromagnetic interference (EMI) in patients who have undergone small bowel capsule endoscopy (SBCE).METHODS:Authors conducted a chart review of 20 patients with a cardiac pacemaker (CP) or implantable cardioverter defibrillator (ICD) who underwent continuous electrocardiographic monitoring during their SBCE from 2003-2008.authors searched for unexplained electrocardiogram (ECG) findings,changes in CP andICD set parameters,any abnormality in transmitted capsule data,and adverse clinical events.RESULTS:There were no adverse events or hemodynamically significant arrhythmias reported.CP and ICD set parameters were preserved.The majority of ECG abnormalities were also found in pre-or post-SBCE ECG tracings and the CP behavior during arrhythmias appeared appropriate.Two patients seemed to have episodes of undersensing by the CP.However,similar findings were documented in ECGs taken outside the time frame of the SBCE.One patient was observed to have a low signal encountered from the capsule resulting in lack of localization,but no images were lost.CONCLUSION:Capsule-induced EMI remains a possibility but is unlikely to be clinically important.CPinduced interference of SBCE is also possible,but is infrequent and does not result in loss of images transmitted by the capsule.
文摘To investigate the mechanisms of microwave induced pacemaker cell injuries, Wistar rats and the primary pacemaker cells of newborn Wistar rats were exposed to microwave at average power density of 50 mW/cm2. Slower spontaneous beating rate, intercellular Ca2+ aggregation and cell membrane perforation were detected immediately after the exposure. Moreover, hyperpolarizationactivated cyclic nucleotide-gated cation channel 4 (HCN4) was down-regulated immediately after the exposure and up-regulated at 12 h after the exposure. In the sinoatrial node (SAN) of the rats,
基金supported by National Key R & D Plan(2017YFC1104202).
文摘BACKGROUND: This study aims to investigate whether small balloon aortic valvuloplasty(BAV) reduces the need for permanent pacemaker implantation (PPMI) after transcatheter aortic valveimplantation (TAVI).METHODS: This was a retrospective analysis using data from our local TAVI database. SmallBAV was defined as a small balloon size (=18 mm) pre-dilatation. Normal BAV was defined as aballoon size >18 mm. The primary endpoint was the incidence of new PPMI.RESULTS: Of 99 consecutive TAVI patients, five patients were excluded due to pre-existingpermanent pacemaker. Patients in the small BAV group (n=57) had a signifi cantly lower PPMI ratecompared with the normal BAV group (n=37) (3.5% vs. 18.9%, P=0.026). Moderate or severe aorticvalve regurgitation post-procedure was similar between the small BAV and normal BAV groups (5.3%vs. 8.1%, P=0.480);likewise, the mean aortic gradient post-procedure did not differ significantly(11.5±5.2 mmHg vs. 12.2±7.3 mmHg, 1 mmHg=0.133 kPa, P=0.580) between the groups. Devicesuccess rates were also similar (94.7% vs. 91.8%, P=0.680). In multivariable analysis, small BAV(P=0.027), the ratio of prosthesis diameter to annulus diameter (P=0.048), and mean aortic gradientby echo in the basement (P=0.021) were independent predictors of PPMI.CONCLUSIONS: The small BAV strategy is associated with a low rate of permanentpacemaker implantation after transcatheter self-expanding valve implantation in this single-centerobservational study.