Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running...Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...展开更多
Traditional single-acting piezoelectric-hydraulic hybrid actuators usually have the problem of inertial force caused by flow pulsation of the liquid,which degrades their output performance.To suppress or solve the ass...Traditional single-acting piezoelectric-hydraulic hybrid actuators usually have the problem of inertial force caused by flow pulsation of the liquid,which degrades their output performance.To suppress or solve the associated inertial force and enhance its output capabilities,this paper proposes a new type of double-acting piezoelectric-hydraulic hybrid actuator with four check valves acting as mechanical diodes.The new hybrid actuator was fabricated and its output performance was tested.When the voltage is 700 Vp-pand the bias pressure is 2 MPa,the pulsation ratesδof the new actuator at 400 Hz,500 Hz and 600 Hz are 2.29,2.08 and 1.78,respectively,whileδof the single-acting hybrid actuator under the same conditions are 10.98,11.05 and 17.12.Therefore,the liquid pulsation rate of the new hybrid actuator is significantly reduced,which is beneficial for improving the flow uniformity and weakening the influence of inertial force on the hybrid actuator.This strategy ultimately leads to a maximum no-load velocity of 168.1 mm/s at 600 Hz and a maximum blocking force of 141 N at 450 Hz for the new hybrid actuator.In addition,this strategy has the potential to be used in other electrohydrostatic actuators to improve their performance.展开更多
基金Supported by National Natural Science Foundation of China (No. 50578048)"Heating, Gas, Ventilation and Air Conditioning" Key Laboratory Open Subject in Beijing (No. KF200710)the Postdoctoral Researcher Science Foundation of China (No. 20090450986)
文摘Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...
基金supported by the funding of the National Natural Science Foundation of China(Grant no.52075518)。
文摘Traditional single-acting piezoelectric-hydraulic hybrid actuators usually have the problem of inertial force caused by flow pulsation of the liquid,which degrades their output performance.To suppress or solve the associated inertial force and enhance its output capabilities,this paper proposes a new type of double-acting piezoelectric-hydraulic hybrid actuator with four check valves acting as mechanical diodes.The new hybrid actuator was fabricated and its output performance was tested.When the voltage is 700 Vp-pand the bias pressure is 2 MPa,the pulsation ratesδof the new actuator at 400 Hz,500 Hz and 600 Hz are 2.29,2.08 and 1.78,respectively,whileδof the single-acting hybrid actuator under the same conditions are 10.98,11.05 and 17.12.Therefore,the liquid pulsation rate of the new hybrid actuator is significantly reduced,which is beneficial for improving the flow uniformity and weakening the influence of inertial force on the hybrid actuator.This strategy ultimately leads to a maximum no-load velocity of 168.1 mm/s at 600 Hz and a maximum blocking force of 141 N at 450 Hz for the new hybrid actuator.In addition,this strategy has the potential to be used in other electrohydrostatic actuators to improve their performance.