Process Analysis of Double Circuit Transmission Line Trip-out on the Same Tower Due to Lightning
1
作者 DUAN Da-peng REN Zhi-gang WANG Peng YE Kuan CHANG Xiao-qi LI Wei 《高压电器》 CAS CSCD 北大核心 2011年第9期31-36,43,共7页
In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th... In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower. 展开更多
关键词 double circuit transmission lines on the same tower lightning trip-out at the same time fault recorder over-voltage calculation lightning protection
下载PDF
The Integrated System of Aerial Photogrammetry and Tower Locations Optimization for Transmission Lines
2
作者 Xie Yuan, Pan Yijun, Fu Bin Northwest Power Design Institute 《Electricity》 1996年第4期45-48,共4页
This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission... This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system. 展开更多
关键词 PRO the Integrated System of Aerial Photogrammetry and tower Locations Optimization for transmission lines
下载PDF
Research on Transmission Line Tower Tilting and Foundation State Monitoring Technology Based onMulti-Sensor Cooperative Detection and Correction
3
作者 Guangxin Zhang Minghui Liu +4 位作者 Shichao Cheng Minzhen Wang Changshun Zhao Hongdan Zhao Gaiming Zhong 《Energy Engineering》 EI 2024年第1期169-185,共17页
The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi... The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation. 展开更多
关键词 transmission line tower tilting MULTI-SENSOR foundation state monitoring collaborative detection
下载PDF
The changing process and trend of ground temperature around tower foundations of Qinghai-Tibet Power Transmission line 被引量:3
4
作者 YanLi Xie QiHao Yu +2 位作者 YanHui You ZhongQiu Zhang TingTao Gou 《Research in Cold and Arid Regions》 CSCD 2019年第1期13-20,共8页
After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing proce... After the construction of Qinghai-Tibet Highway and Railway, the Qinghai-Tibet Power Transmission(QTPT) line is another major permafrost engineering project with new types of engineering structures. The changing process and trend of ground temperature around tower foundations are crucial for the stability of QTPT. We analyzed the change characteristics and tendencies of the ground temperature based on field monitoring data from 2010 to 2014. The results reveal that soil around the tower foundations froze and connected with the artificial permafrost induced during the construction of footings after the first freezing period, and the soil below the original permafrost table kept freezing in subsequent thawing periods. The ground temperature lowered to that of natural fields, fast or slowly for tower foundations with thermosyphons,while for tower foundations without thermosyphons, the increase in ground temperature resulted in higher temperature than that of natural fields. Also, the permafrost temperature and ice content are significant factors that influence the ground temperature around tower foundations. Specifically, the ground temperature around tower foundations in warm and ice-rich permafrost regions decreased slowly, while that in cold and ice poor permafrost regions cooled faster. Moreover, foundations types impacted the ground temperature, which consisted of different technical processes during construction and variant of tower footing structures. The revealed changing process and trend of the ground temperature is beneficial for evaluating the thermal regime evolution around tower foundations in the context of climate change. 展开更多
关键词 Qinghai-Tibet Power transmission line tower FOUNDATIon ground temperature change CHARACTERISTIC TREND
下载PDF
OPTIMIZATION OF TRANSIENT FEEDING TO PARALLEL-PLATE TRANSMISSION LINES FROM COAXIAL LINE 被引量:4
5
作者 Tian Chunming Wang Jianguo Meng Fenxia Zhang Maoyu Ge Debiao(Department of Physics, Xidian University, Xi’an 710071) (Northwest Institute of Nuclear Technology, P. O. Box 69-15, Xi’an 710024) 《Journal of Electronics(China)》 2001年第3期281-284,共4页
The transient feeding to parallel-plate transmission lines from coaxial line is optimized by using the Finite-Difference Time-Domain (FDTD) method and a simple FDTD feed model. Observing the reflected voltages, this l... The transient feeding to parallel-plate transmission lines from coaxial line is optimized by using the Finite-Difference Time-Domain (FDTD) method and a simple FDTD feed model. Observing the reflected voltages, this letter presents the optimal feeding position and ratio of width to height for a given input impedance of the coaxial line. 展开更多
关键词 FDTD method parallel-plate transmission lines
下载PDF
Coupling analysis of transmission lines excited by space electromagnetic fields based on time domain hybrid method using parallel technique 被引量:1
6
作者 Zhi-Hong Ye Xiao-Lin Wu Yao-Yao Li 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第9期249-254,共6页
We present a time domain hybrid method to realize the fast coupling analysis of transmission lines excited by space electromagnetic fields, in which parallel finite-difference time-domain (FDTD) method, interpolation ... We present a time domain hybrid method to realize the fast coupling analysis of transmission lines excited by space electromagnetic fields, in which parallel finite-difference time-domain (FDTD) method, interpolation scheme, and Agrawal model-based transmission line (TL) equations are organically integrated together. Specifically, the Agrawal model is employed to establish the TL equations to describe the coupling effects of space electromagnetic fields on transmission lines. Then, the excitation fields functioning as distribution sources in TL equations are calculated by the parallel FDTD method through using the message passing interface (MPI) library scheme and interpolation scheme. Finally, the TL equations are discretized by the central difference scheme of FDTD and assigned to multiple processors to obtain the transient responses on the terminal loads of these lines. The significant feature of the presented method is embodied in its parallel and synchronous calculations of the space electromagnetic fields and transient responses on the lines. Numerical simulations of ambient wave acting on multi-conductor transmission lines (MTLs), which are located on the PEC ground and in the shielded cavity respectively, are implemented to verify the accuracy and efficiency of the presented method. 展开更多
关键词 Agrawal model transmission line equations parallel FDTD method message passing interface(MPI)library
下载PDF
Accurate Fault Location Modeling for Parallel Transmission Lines Considering Mutual Effect 被引量:1
7
作者 Hamdy A.Ziedan Hegazy Rezk Mujahed Al-Dhaifallah 《Computers, Materials & Continua》 SCIE EI 2021年第4期491-518,共28页
:A new accurate algorithms based on mathematical modeling of two parallel transmissions lines system(TPTLS)as influenced by the mutual effect to determine the fault location is discussed in this work.The distance rela... :A new accurate algorithms based on mathematical modeling of two parallel transmissions lines system(TPTLS)as influenced by the mutual effect to determine the fault location is discussed in this work.The distance relay measures the impedance to the fault location which is the positive-sequence.The principle of summation the positive-,negative-,and zero-sequence voltages which equal zero is used to determine the fault location on the TPTLS.Also,the impedance of the transmission line to the fault location is determined.These algorithms are applied to single-line-to-ground(SLG)and double-line-to-ground(DLG)faults.To detect the fault location along the transmission line,its impedance as seen by the distance relay is determined to indicate if the fault is within the relay’s reach area.TPTLS under study are fed from one-and both-ends.A schematic diagrams are obtained for the impedance relays to determine the fault location with high accuracy. 展开更多
关键词 New accurate algorithms mathematical modeling fault location scheme diagrams parallel transmission lines mutual effect SLG and DLG faults
下载PDF
A New Principle of Fault Identification of on the Same Tower Based on Traveling Wave Reactive Powers
8
作者 Hao Wu Ruikai Ye +2 位作者 Xingxing Dong Kunjian Yu Zhengwei Chang 《Journal of Power and Energy Engineering》 2019年第7期50-70,共21页
In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based ... In order to improve the reliability of fault identification of the double-circuit transmission lines on the same tower, a new algorithm for fast protection of double-circuit transmission lines on the same tower based on the reactive powers of traveling wave is proposed. With the implementation of S-transform, the initial traveling wave reactive powers are calculated and the change characteristics of reactive power under different fault conditions are studied. The protection criterion is constructed by analyzing the ratio of the reactive powers of the same end on double-circuit transmission lines and the ratio of the reactive powers at both ends on the same line. According to the ratio of reactive power on the same side of the line and both ends of the same line, it is possible to identify whether the faults of the double-circuit line of the same tower occurred in or out of the protection zone. A large number of simulation results show that the protection performance is sensitive and reliable, and quick to respond. The criterion is simple and is basically not affected by fault initial angles, fault types, and transitional resistances. 展开更多
关键词 Double-Circuit transmission Line on the same tower TRAVELING Wave Reactive Power S-TRANSFORM Fault Identification
下载PDF
Fault location for parallel transmission lines using one-terminal current traveling waves
9
作者 徐青山 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第3期408-412,共5页
With proper phase module transformation,parallel lines can be decomposed to the same directional net and the reverse directional net. The propagation characteristics of traveling waves in the reverse directional net w... With proper phase module transformation,parallel lines can be decomposed to the same directional net and the reverse directional net. The propagation characteristics of traveling waves in the reverse directional net were analyzed,and the refraction coefficient at the fault point for a single phase fault was derived. In addition,the module selection was discussed. Simulation results show that satisfying accuracy can be achieved with the proposed method. Moreover,it is immune to fault types,fault resistances,and outside system parameters. 展开更多
关键词 fault location parallel transmission lines traveling wave reverse directional net
下载PDF
Online One-End Fault Location Algorithm for Parallel Transmission Lines
10
作者 Wanjing Xiu Yuan Liao 《Smart Grid and Renewable Energy》 2011年第4期359-366,共8页
Fault location and distance protection are essential smart grid technologies ensuring reliability of the power system. This paper describes an accurate algorithm for locating faults on double-circuit transmission line... Fault location and distance protection are essential smart grid technologies ensuring reliability of the power system. This paper describes an accurate algorithm for locating faults on double-circuit transmission lines. The proposed approach is capable of identifying the faulted circuit of a parallel transmission line by checking the estimated fault location and fault resistance. Voltage and current measurements from only one of the terminals of the faulty line are used. No pre-fault data are required for the estimation. The lumped parameter line model considering shunt capacitance is utilized for the derivation of the algorithm. It’s assumed that line parameters are known and transmission lines are fully transposed. The method is applicable to all types of faults. It’s evinced by evaluation studies that the proposed algorithm can correctly determine the faulted circuit in most cases. For exceptional cases, the current waveforms during the fault can be used to help identify the faulted circuit. The proposed algorithm generates quite accurate fault location estimates, and may be suitable for distance relaying. 展开更多
关键词 DISTANCE Protection FAULT LOCATIon parallel transmission LINE
下载PDF
Dynamic Analysis of Overhead Transmission Lines under Turbulent Wind Loading 被引量:2
11
作者 Alok Dua Mathias Clobes +1 位作者 Thomas Hobbel Vasant Matsagar 《Open Journal of Civil Engineering》 2015年第4期359-371,共13页
Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode.... Transmission tower-line systems are designed using static loads specified in various codes. This paper compares the dynamic response of a test transmission line with the response due to static loads given by Eurocode. Finite element design software SAP2000 was used to model the towers and lines. Non-linear dynamic analysis including the large displacement effects was carried out. Macroscopic aspects of wind coherence along element length and integration time step were investigated. An approach is presented to compare the probabilistic dynamic response due to 7 different stochastically simulated wind fields with the response according to EN-50341. The developed model will be used to study the response recorded on a test line due to the actual wind speed time history recorded. It was found that static load from EN overestimated the strength of conductor cables. The response of coupled system considering towers and cables was found to be different from response of only cables with fixed supports. 展开更多
关键词 Dynamic Analysis Finite Element Method SAP2000 transmission towers transmission lines
下载PDF
Evaluating transmission towers potentials during ground faults
12
作者 Maria VINTAN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第2期182-189,共8页
During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper pres... During ground faults on transmission lines,a number of towers near the fault are likely to acquire high potentials to ground.These tower voltages,if excessive,may present a hazard to humans and animals.This paper presents analytical methods in order to determine the transmission towers potentials during ground faults,for long and short lines.The author developed a global systematic approach to calculate these voltages,which are dependent of a number of factors.Some of the most important factors are:magnitudes of fault currents,fault location with respect to the line terminals,conductor arrangement on the tower and the location of the faulted phase,the ground resistance of the faulted tower,soil resistivity,number,material and size of ground wires.The effects of these factors on the faulted tower voltages have been also examined for different types of power lines. 展开更多
关键词 Overhead transmission lines Ground fault tower potential
下载PDF
Dynamic Responses of Long-Span Transmission Tower-Line System Subjected to Broken Wires
13
作者 夏正春 李黎 +1 位作者 方秦汉 龙晓鸿 《Journal of Southwest Jiaotong University(English Edition)》 2008年第4期309-319,共11页
A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlineari... A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlinearity of wires and suspension insulators are considered, but also the support towers are included. The incremental and iterative approaches are combined by applying the unbalanced loads incrementally during each iteration cycle. The approach was illustrated with an example of a Hanjiang- River long-span transmission line system subjected to a shield wire and a conductor failure, respectively. The analysis results showed that the proposed dynamic simulation approach can demonstrate the kinetic process of the tower-line system subjected to wire ruptures: The frequencies of line components were lower and densely distributed, but the frequencies of tower components were higher and sparsely distributed. Anyhow, the dynamic effects of wire ruptures on tower-line system could not be ignored in analysis of tower-line system subjected wire failures. 展开更多
关键词 Electric transmission tower-line coupling Wire rupture Dynamic responses ANSYS/LS-DYNA
下载PDF
一种采用Slave_B传输模式的LonWorks电力线节点 被引量:4
14
作者 田敏 杨帅 薛岚 《自动化仪表》 CAS 北大核心 2011年第12期13-15,19,共4页
为提高LonWorks系统在电力线信道上进行多进程、多任务并行处理时的实时性,介绍了一种在主机AT89S51与从机MC143150之间采用Slave_B并行传输模式的LonWorks电力线节点。数据通信通过传递虚拟令牌得以实现,解决了数据总线传输冲突问题;... 为提高LonWorks系统在电力线信道上进行多进程、多任务并行处理时的实时性,介绍了一种在主机AT89S51与从机MC143150之间采用Slave_B并行传输模式的LonWorks电力线节点。数据通信通过传递虚拟令牌得以实现,解决了数据总线传输冲突问题;节点配以路由器和iLON100构建的主干式网络,保证了数据在电力线信道上的及时处理。实际应用表明,相对于传统基于神经元芯片类型的LonWorks节点,基于Slave_B并行传输模式的电力线节点控制能力得到增强。 展开更多
关键词 LonWORKS 节点 电力线 并行传输 虚拟令牌 实时性
下载PDF
基于人工传输线的小型平衡型Wilkinson功分器(英文)
15
作者 黄文 阮巍 董金生 《强激光与粒子束》 EI CAS CSCD 北大核心 2016年第9期95-98,共4页
提出了一种基于人工传输线并采用双面平行带状线实现的小型平衡型Wilkinson功分器。该器件采用人工传输线取代传统传输线以减少电路尺寸,同时引入双面平行带状线结构用来实现功分器平衡的功能。设计的功分器尺寸仅为传统Wilkinson功分器... 提出了一种基于人工传输线并采用双面平行带状线实现的小型平衡型Wilkinson功分器。该器件采用人工传输线取代传统传输线以减少电路尺寸,同时引入双面平行带状线结构用来实现功分器平衡的功能。设计的功分器尺寸仅为传统Wilkinson功分器的25%。测试结果表明,设计制作的平衡Wilkinson功分器在0.83GHz至1.05GHz带宽范围内相位平衡度±1.28°,幅度平衡度±0.17dB,回波损耗大于16.79dB,端口隔离度大于16.21dB。测量结果和仿真结果吻合良好,证实了该功分器具有良好的性能。 展开更多
关键词 平衡 小型化 WILKINSon功分器 人工传输线 双面平行带状线
下载PDF
融入attention机制的台风风险预警模型
16
作者 李晓帆 《云南电力技术》 2020年第1期12-16,共5页
台风是一种可以给沿海地区电网造成巨大破坏的自然灾害,中国东南沿海地区正是台风灾害频发的地区。对于强台风环境下的地区电网,台风的强风可导致输配电网中的电气设备产生结构性损伤,影响供电稳定性。在电网设备中,杆塔是最易被台风影... 台风是一种可以给沿海地区电网造成巨大破坏的自然灾害,中国东南沿海地区正是台风灾害频发的地区。对于强台风环境下的地区电网,台风的强风可导致输配电网中的电气设备产生结构性损伤,影响供电稳定性。在电网设备中,杆塔是最易被台风影响的大型设备,从中国东南沿海电网历史台风灾损统计结果来看,绝大多数的倒塔与断杆主要发生在强风圈内,显然风速对杆塔的影响是巨大的。 展开更多
关键词 台风预警 多层神经网络 微地形 杆塔类型 输电线路
下载PDF
颗粒阻尼器对输电塔线系统减震性能研究
17
作者 鲁正 沈也雷 +2 位作者 谭淇航 荣坤杰 田利 《工程力学》 EI CSCD 北大核心 2024年第7期9-18,共10页
对输电塔线系统进行缩尺模型振动台实验,从时域和频域的角度,对比了调谐质量阻尼器和颗粒阻尼器对输电塔的减震效果。利用ABAQUS建立了颗粒阻尼器控制输电塔线系统的离散元-有限元高精度耦合数值模型,对比了实验和模拟结果,并对塔线系... 对输电塔线系统进行缩尺模型振动台实验,从时域和频域的角度,对比了调谐质量阻尼器和颗粒阻尼器对输电塔的减震效果。利用ABAQUS建立了颗粒阻尼器控制输电塔线系统的离散元-有限元高精度耦合数值模型,对比了实验和模拟结果,并对塔线系统的耗能情况及颗粒阻尼器内部颗粒运动碰撞情况进行分析。研究结果表明:在地震激励下,颗粒阻尼器的减震效果较调谐质量阻尼器有更好的鲁棒性;该文所建立的颗粒阻尼器控制输电塔线系统模型能够良好地反映试件的动力特性和地震响应;在颗粒阻尼器的控制下,塔线系统总能量降低24.12%。当颗粒之间的碰撞次数和颗粒与容器的碰撞次数满足一定比例关系时,颗粒阻尼器能实现更优的控制效果。 展开更多
关键词 输电塔线系统 颗粒阻尼器 离散单元法 减震性能 振动台实验
下载PDF
端接复杂电路传输线网络的电磁耦合时域并行计算方法
18
作者 叶志红 张玉 鲁唱唱 《电子与信息学报》 EI CAS CSCD 北大核心 2024年第2期713-719,共7页
针对端接复杂电路传输线(TL)网络的电磁耦合问题,仍缺乏高效的场路协同仿真技术。该文将传输线方程与时域有限差分(FDTD)方法、诺顿定理和置换定理以及NGSPICE软件相结合,并引入消息传递接口(MPI)并行技术,提出一种高效的时域混合并行算... 针对端接复杂电路传输线(TL)网络的电磁耦合问题,仍缺乏高效的场路协同仿真技术。该文将传输线方程与时域有限差分(FDTD)方法、诺顿定理和置换定理以及NGSPICE软件相结合,并引入消息传递接口(MPI)并行技术,提出一种高效的时域混合并行算法(FDTDTL-NGSPICE)。首先,根据诺顿定理和置换定理,将传输线网络分解为传输线子系统和复杂电路子系统,并构建对应的等效电路模型。然后,使用FDTDTL并行算法计算传输线子系统沿线各点的电压和电流,并获取对应诺顿等效电路的电流源和等效导纳大小。最后,使用NGSPICE对复杂电路子系统进行传导干扰分析,获得复杂电路各元件上的瞬态响应,并将端口电压反馈给传输线子系统作为边界,实现传输线网络电磁耦合的场线路联合协同仿真。通过对3类典型场景的计算实例,分别使用时域混合并行算法和电磁仿真软件CST电缆工作室(CS)进行数值模拟并对比,验证所提算法的置信度。 展开更多
关键词 传输线网络 复杂电路 诺顿定理 时域有限差分与传输线方程的混合并行算法 NGSPICE软件
下载PDF
基于杆塔点云数据的数字化输电线路防雷性能评估技术
19
作者 邬蓉蓉 黄志都 +2 位作者 黄维 唐捷 徐文平 《沈阳工业大学学报》 CAS 北大核心 2024年第6期735-741,共7页
针对气象条件、线路长度等因素对防雷性能产生影响,导致防雷性能评估准确度下降的问题,提出基于杆塔点云数据的数字化输电线路防雷性能评估技术。利用机载三维激光扫描技术获取杆塔点云数据,实施去噪和精简处理,提取杆塔特征参数和地形... 针对气象条件、线路长度等因素对防雷性能产生影响,导致防雷性能评估准确度下降的问题,提出基于杆塔点云数据的数字化输电线路防雷性能评估技术。利用机载三维激光扫描技术获取杆塔点云数据,实施去噪和精简处理,提取杆塔特征参数和地形地貌特征参数,结合其他特征构成雷击风险评估指标体系。计算雷击跳闸概率值,明确雷击跳闸风险;计算输电线路的防雷程度值,确定对应的防雷等级。实验结果表明,所提方法的防雷性能评估结果与历史数据初步判定的防雷性能结果一致,该技术可以显著提高输电线路防雷性能评估的精度。 展开更多
关键词 杆塔点云数据 数字化输电线路 雷击跳闸概率 防雷性能 机载三维激光扫描 杆塔特征 气象特征 地形地貌特征
下载PDF
750kV单回并行输电线路电磁辐射环境研究
20
作者 任定高 《铀矿冶》 CAS 2024年第1期93-98,共6页
采用《环境影响评价技术导则输变电》(HJ 24—2020)附录C、D推荐的计算模式对750 kV单回并行输电线路电磁辐射环境进行计算与预测。结果表明,经过耕地、园地、牧草地、畜禽饲养地、道路等场所,当导线对地最小高度为15.5 m时,单回并行线... 采用《环境影响评价技术导则输变电》(HJ 24—2020)附录C、D推荐的计算模式对750 kV单回并行输电线路电磁辐射环境进行计算与预测。结果表明,经过耕地、园地、牧草地、畜禽饲养地、道路等场所,当导线对地最小高度为15.5 m时,单回并行线路下的工频电场强度最大值超过10 kV/m;需将导线对地最小高度提至16.5 m,才能满足4 kV/m控制限值要求。750 kV单回并行输电线路产生的工频磁场强度小于公众曝露控制限值(100μT),一般情况下不会成为线路建设的环境制约因素;但其产生的工频电场是电磁环境影响的主要因素,电场强度控制限值(4 kV/m)是线路建设的环境制约因素,同时也是输变电电磁环境重点控制因素。现场实测结果与理论预测结果符合性较好,表明采用的预测模式具有较好的应用性,研究结果可为750 kV单回并行输电线路的建设和环境监管提供支持。 展开更多
关键词 工频电场 工频磁场 电磁辐射环境 单回并行线路 输电线路
下载PDF