The merits of compressed air energy storage(CAES)include large power generation capacity,long service life,and environmental safety.When a CAES plant is switched to the grid-connected mode and participates in grid reg...The merits of compressed air energy storage(CAES)include large power generation capacity,long service life,and environmental safety.When a CAES plant is switched to the grid-connected mode and participates in grid regulation,using the traditional control mode with low accuracy can result in excess grid-connected impulse current and junction voltage.This occurs because the CAES output voltage does not match the frequency,amplitude,and phase of the power grid voltage.Therefore,an adaptive linear active disturbance-rejection control(A-LADRC)strategy was proposed.Based on the LADRC strategy,which is more accurate than the traditional proportional integral controller,the proposed controller is enhanced to allow adaptive adjustment of bandwidth parameters,resulting in improved accuracy and response speed.The problem of large impulse current when CAES is switched to the grid-connected mode is addressed,and the frequency fluctuation is reduced.Finally,the effectiveness of the proposed strategy in reducing the impact of CAES on the grid connection was verified using a hardware-in-the-loop simulation platform.The influence of the k value in the adaptive-adjustment formula on the A-LADRC was analyzed through simulation.The anti-interference performance of the control was verified by increasing and decreasing the load during the presynchronization process.展开更多
With the rapid development of digital signal processing chip in recent years, DSP began to be used in more switching power supply. The advantages of digital control of their own, making the digital control PFC become ...With the rapid development of digital signal processing chip in recent years, DSP began to be used in more switching power supply. The advantages of digital control of their own, making the digital control PFC become a hotspot research. However, compared with the simulation system, the digital control technology still has many problems. In this paper, the problem of digital PI compensator as a voltage compensator is discussed, and the Single-pole voltage loop compensator is used in digital control PFC circuit. Because current loop bandwidth is narrow, a method to expand current loop bandwidth is put forward. Output power 300 W of prototype is made, and experimental results verify the correctness of the theory.展开更多
介绍了全光纤电流互感器(allfiber-optic current sensor,A-FOCS)的工作原理。针对输出信号特点,应用方波调制提高系统响应灵敏度,相关解调提取相位信息。在此基础上,引入阶梯波反馈技术,在2束相干偏振光间叠加一个与法拉第(Faraday)相...介绍了全光纤电流互感器(allfiber-optic current sensor,A-FOCS)的工作原理。针对输出信号特点,应用方波调制提高系统响应灵敏度,相关解调提取相位信息。在此基础上,引入阶梯波反馈技术,在2束相干偏振光间叠加一个与法拉第(Faraday)相移大小相等、方向相反的非互易相位差,实现闭环检测。提出三倍频方波调制方法,提高检测速度、增大闭环系统检测带宽。测试结果表明,闭环系统在-40^+60℃范围内标度因数变化小于±0.25%,接近IEC标准0.2s级(±0.2%);系统带宽大于6kHz;分辨能力小于0.5A。试验结果证明了信号处理方法的正确性。展开更多
为实现三相直流侧有源电力滤波器的数字控制,提出将平均电流控制应用于三相直流侧并联型有源电力滤波器(active power filter,APF)的控制。为设计电流补偿器,提出定量分析电流环带宽和交流侧输入电流补偿性能关系的方法。该方法分析结...为实现三相直流侧有源电力滤波器的数字控制,提出将平均电流控制应用于三相直流侧并联型有源电力滤波器(active power filter,APF)的控制。为设计电流补偿器,提出定量分析电流环带宽和交流侧输入电流补偿性能关系的方法。该方法分析结果表明在输入频率为50Hz的情况下,且三相直流侧APF的电流环带宽超过1kHz时,可在输入端实现较好的谐波电流补偿性能。通过利用建立的电压环和电流环数学模型,设计完成的实验样机测试结果表明,在电流环带宽为1和2kHz下的补偿效果相当,证明了平均电流控制在三相直流侧APF中应用的有效性,同时也证明了定量分析电流环带宽和补偿性能关系方法的正确性。展开更多
基金supported by National Natural Science Foundation of China(Project No.52077079).
文摘The merits of compressed air energy storage(CAES)include large power generation capacity,long service life,and environmental safety.When a CAES plant is switched to the grid-connected mode and participates in grid regulation,using the traditional control mode with low accuracy can result in excess grid-connected impulse current and junction voltage.This occurs because the CAES output voltage does not match the frequency,amplitude,and phase of the power grid voltage.Therefore,an adaptive linear active disturbance-rejection control(A-LADRC)strategy was proposed.Based on the LADRC strategy,which is more accurate than the traditional proportional integral controller,the proposed controller is enhanced to allow adaptive adjustment of bandwidth parameters,resulting in improved accuracy and response speed.The problem of large impulse current when CAES is switched to the grid-connected mode is addressed,and the frequency fluctuation is reduced.Finally,the effectiveness of the proposed strategy in reducing the impact of CAES on the grid connection was verified using a hardware-in-the-loop simulation platform.The influence of the k value in the adaptive-adjustment formula on the A-LADRC was analyzed through simulation.The anti-interference performance of the control was verified by increasing and decreasing the load during the presynchronization process.
文摘With the rapid development of digital signal processing chip in recent years, DSP began to be used in more switching power supply. The advantages of digital control of their own, making the digital control PFC become a hotspot research. However, compared with the simulation system, the digital control technology still has many problems. In this paper, the problem of digital PI compensator as a voltage compensator is discussed, and the Single-pole voltage loop compensator is used in digital control PFC circuit. Because current loop bandwidth is narrow, a method to expand current loop bandwidth is put forward. Output power 300 W of prototype is made, and experimental results verify the correctness of the theory.
文摘介绍了全光纤电流互感器(allfiber-optic current sensor,A-FOCS)的工作原理。针对输出信号特点,应用方波调制提高系统响应灵敏度,相关解调提取相位信息。在此基础上,引入阶梯波反馈技术,在2束相干偏振光间叠加一个与法拉第(Faraday)相移大小相等、方向相反的非互易相位差,实现闭环检测。提出三倍频方波调制方法,提高检测速度、增大闭环系统检测带宽。测试结果表明,闭环系统在-40^+60℃范围内标度因数变化小于±0.25%,接近IEC标准0.2s级(±0.2%);系统带宽大于6kHz;分辨能力小于0.5A。试验结果证明了信号处理方法的正确性。
文摘为实现三相直流侧有源电力滤波器的数字控制,提出将平均电流控制应用于三相直流侧并联型有源电力滤波器(active power filter,APF)的控制。为设计电流补偿器,提出定量分析电流环带宽和交流侧输入电流补偿性能关系的方法。该方法分析结果表明在输入频率为50Hz的情况下,且三相直流侧APF的电流环带宽超过1kHz时,可在输入端实现较好的谐波电流补偿性能。通过利用建立的电压环和电流环数学模型,设计完成的实验样机测试结果表明,在电流环带宽为1和2kHz下的补偿效果相当,证明了平均电流控制在三相直流侧APF中应用的有效性,同时也证明了定量分析电流环带宽和补偿性能关系方法的正确性。