期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Off-Design Performance of Gas Turbine Power Units with Alternative Load-Control Strategies
1
作者 Zhiqiang Pan Zhiwen Lin +2 位作者 Kunle Fan Cheng Yang Xiaoqian Ma 《Energy Engineering》 EI 2021年第1期119-141,共23页
Gas turbine power units,as an effective way to cope with the severe challenge of renewable energy accommodation in power grids,arouse the interest of power enterprises in the deep peak-load regulation performance.Two ... Gas turbine power units,as an effective way to cope with the severe challenge of renewable energy accommodation in power grids,arouse the interest of power enterprises in the deep peak-load regulation performance.Two common alternative load-control strategies including constant turbine inlet temperature(TIT)and constant turbine exhaust temperature(TET)regulations were taken into consideration.To comparatively investigate the part-load performance under these strategies,both mathematical and physical models were set up successively to serve as a validation and complementary to each other.For the mathematical model of compressor with inlet guide vane(IGV),combustor and turbine,stage-stacking method based on blade average geometric parameter,energy conservation and turbine stage model were adopted respectively.For the physical model,design and off-design analysis were carried out based on GT PRO and THERMOFLEX respectively.The simulation result of mathematical model validated the reliability of the physical model.Based on this,the influence of ambient temperature and different load-regulating strategies on the off-design performance of gas turbine power units was studied in THERMOFLEX.The results in the case of a PG 9351FA gas turbine show that the ambient temperature has a great impact on system performance,i.e.,every 5℃ increase in the ambient temperature produces a reduction of 3.7%in the relative full-load output and 1.1%in the relative efficiency respectively;when the gas turbine operates under constant TIT strategy,TET starts to rise till it reaches the maximum allowable value with the load rate decreasing,and IGV keeps at the minimum angle with both TIT and TET decreasing when the load rate is lower than 65%;when the gas turbine operates under constant TET strategy,TIT drops slightly at load rate of above 60%while both TIT and TET evidently decrease below 60%load rate operating along the constant corrected speed line at the minimum allowable IGV opening;gas turbine effi-ciency is greatly affected by load rate and the performance degradation is more obvious especially in lower load rate regions;constant TET strategy is superior in the operating efficiency to constant TIT strategy under part-load conditions. 展开更多
关键词 Gas turbine part load performance operating strategy comparative simulation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部