An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is propose...An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is proposed to get rid of both sinusoidal continuous noise and other external discharges.展开更多
The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a nu...The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a number of simulations. The simulations were based on the well-known three capacitor model for partial discharge. An equivalent circuit was derived for partial discharge due to a single void in the insulation material of a power cable. The results obtained from the simulations will form the basis of the design proses of a non-intrusive condition monitoring technique. The technique is based on the classification of discharge activity according to five levels of PD. Future work will include the improvement of the simulation model by investigating the high frequency model of a power cable as well as the statistical nature of PD activity. This will improve the accuracy of the simulation results when compared to actual measurements. The work discussed in this paper will be used to construct and calibrate a practical model which will make use of PD measurements for non-intrusive condition monitoring of medium voltage electrical cables.展开更多
This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF...This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF monitor used the high frequency current mutual inductor to detect the partial discharge signal from neutral wire of stator windings. According to the magnitude of indicative value of RF monitor, a five phase model was also proposed to manage the generator’s running better. The practices show that the proposed method is effective.展开更多
Non-intrusive measurement technology is of great interest for the electrical utilities in order to avoid an interruption in the normal operation of the supply network during diagnostics measurements and inspections. I...Non-intrusive measurement technology is of great interest for the electrical utilities in order to avoid an interruption in the normal operation of the supply network during diagnostics measurements and inspections. Inductively coupled electromagnetic sensing provides a possibility of non-intrusive measurements for online condition monitoring of the electrical components in a Medium Voltage (MV) distribution network. This is accomplished by employing Partial Discharge (PD) activity monitoring, one of the successful methods to assess the working condition of MV components but often requires specialized equipment for carrying out the measurements. In this paper, Rogowski coil sensor is presented as a robust solution for non-intrusive measurements of PD signals. A high frequency prototype of Rogowski coil is designed in the laboratory. Step-by-step approach of constructing the sensor system is presented and performance of its components (coil head, damping component, integrator and data acquisition system) is evaluated using practical and simulated environments. Alternative Transient Program-Electromagnetic Transient Program (ATP-EMTP) is used to analyze the designed model of the Rogowski coil. Real and simulated models of the coil are used to investigate the behavior of Rogowski coil sensor at its different stages of development from a transducer coil to a complete measuring device. Both models are compared to evaluate their accuracy for PD applications. Due to simple design, flexible hardware, and low cost of Rogowski coil, it can be considered as an efficient current measuring device for integrated monitoring applications where a large number of sensors are required to develop an automated online condition monitoring system for a distribution network.展开更多
To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD ...To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD UHF online monitoring in transformer is excessively large,therefore,it is not convenient for internal installation of transformer. Two types of compact UHF antennas with small sizes,a Hilbert fractal antenna and a small loop antenna are presented. PD experiments of three typically artificial insulation defects are executed and both antennas are used for PD measurement. The spectra of power via frequency of detected PD signals are analyzed and compared. The experimental results show that the Hilbert fractal antenna and small loop antenna are qualified for PD online UHF monitoring.展开更多
This paper introduces a computerized on-line partial discharge (PD) monitoring and diagnostic system for transformers. The system, which is already in use in a power station, uses wide-band active transducers and a ...This paper introduces a computerized on-line partial discharge (PD) monitoring and diagnostic system for transformers. The system, which is already in use in a power station, uses wide-band active transducers and a data acquisition unit with modularized and exchangeable components. The system software is a power equipment monitoring and diagnostic system, which is based on the component object model, and was developed for monitoring multiple parameters in multiple power supply systems. The statistical characteristics of PDs in power transformers were studied using 7 experimental models for simulating PDs in transformers and 3 models for simulating interfering discharges in air. The discharge features were analyzed using a 3-D pattern chart with a three-layer back-propagation artificial neural network used to recognize the patterns. The results show that PDs in air and oil can be distinguished. The model can be used for interference rejection on-line monitoring of partial discharge in transformers.展开更多
特高压直流GIL运行可靠性取决于内绝缘设计的可靠性。此外,导电元件直流电流密度的取值、弹簧触头的定位设计、GIL各元件中的绝缘件与金具连接处的楔形气隙的处理以及母线中支撑件的结构设计细节,都会对产品运行可靠性产生重大影响,不...特高压直流GIL运行可靠性取决于内绝缘设计的可靠性。此外,导电元件直流电流密度的取值、弹簧触头的定位设计、GIL各元件中的绝缘件与金具连接处的楔形气隙的处理以及母线中支撑件的结构设计细节,都会对产品运行可靠性产生重大影响,不能忽视。对于运行环境十分严酷的UHV DC GIL为保证内绝缘工作可靠性和减少气体维护工作量,文中还提出了高气密性结构设计。为适应-50℃低温运行要求,产品选用了液化温度很低的N_(2)/SF_(6)混合气体,对两种气体的配比,压力特性和绝缘特性进行了讨论与计算。还有产品的局放、气体密度及微水含量的监视系统的可靠性设计,都会对产品运行可靠性产生直接影响。文中对上述问题的研究成果作了介绍,可供高压直流产品设计使用。对其中未解的新技术如基于冷镜露点测试原理、微机电技术制作的智能气体湿度和密度监测装置、高压直流复合绝缘套管伞面局放起始场强提出了研究方案。文中提出的诸多GIL运行可靠性设计要点,对于其他超/特高压直流气体绝缘电器可参考选用。展开更多
文摘An on-line monitoring system for partial discharge from high voltage transformer is presented with structure of hardware and principle of software discussed and a new effective method combining DFT with DWT is proposed to get rid of both sinusoidal continuous noise and other external discharges.
文摘The purpose of this paper is to investigate the effect of PD (partial discharge) activity within medium voltage XLPE (cross-linked polyethylene) cables. The effect of partial discharge was studied by means of a number of simulations. The simulations were based on the well-known three capacitor model for partial discharge. An equivalent circuit was derived for partial discharge due to a single void in the insulation material of a power cable. The results obtained from the simulations will form the basis of the design proses of a non-intrusive condition monitoring technique. The technique is based on the classification of discharge activity according to five levels of PD. Future work will include the improvement of the simulation model by investigating the high frequency model of a power cable as well as the statistical nature of PD activity. This will improve the accuracy of the simulation results when compared to actual measurements. The work discussed in this paper will be used to construct and calibrate a practical model which will make use of PD measurements for non-intrusive condition monitoring of medium voltage electrical cables.
文摘This study presented an insulation state monitoring method for large generator based on radio frequency (RF) technique. As an on-line condition monitor and the precondition of condition-based maintenance (CBM), the RF monitor used the high frequency current mutual inductor to detect the partial discharge signal from neutral wire of stator windings. According to the magnitude of indicative value of RF monitor, a five phase model was also proposed to manage the generator’s running better. The practices show that the proposed method is effective.
文摘Non-intrusive measurement technology is of great interest for the electrical utilities in order to avoid an interruption in the normal operation of the supply network during diagnostics measurements and inspections. Inductively coupled electromagnetic sensing provides a possibility of non-intrusive measurements for online condition monitoring of the electrical components in a Medium Voltage (MV) distribution network. This is accomplished by employing Partial Discharge (PD) activity monitoring, one of the successful methods to assess the working condition of MV components but often requires specialized equipment for carrying out the measurements. In this paper, Rogowski coil sensor is presented as a robust solution for non-intrusive measurements of PD signals. A high frequency prototype of Rogowski coil is designed in the laboratory. Step-by-step approach of constructing the sensor system is presented and performance of its components (coil head, damping component, integrator and data acquisition system) is evaluated using practical and simulated environments. Alternative Transient Program-Electromagnetic Transient Program (ATP-EMTP) is used to analyze the designed model of the Rogowski coil. Real and simulated models of the coil are used to investigate the behavior of Rogowski coil sensor at its different stages of development from a transducer coil to a complete measuring device. Both models are compared to evaluate their accuracy for PD applications. Due to simple design, flexible hardware, and low cost of Rogowski coil, it can be considered as an efficient current measuring device for integrated monitoring applications where a large number of sensors are required to develop an automated online condition monitoring system for a distribution network.
基金Project Supported by New Century ExcellentTalents of the Ministry of Education (NCET-06-0763)the Foundation of the Key Project of the Science and Technology Depart ment inChongqing (CSTC2005AA6003)
文摘To investigate the partial discharge (PD) online monitoring of transformers by ultra-high-frequency (UHF) approaches,high-qualified UHF antennas are focused on as one key technique. The size of UHF sensor used for PD UHF online monitoring in transformer is excessively large,therefore,it is not convenient for internal installation of transformer. Two types of compact UHF antennas with small sizes,a Hilbert fractal antenna and a small loop antenna are presented. PD experiments of three typically artificial insulation defects are executed and both antennas are used for PD measurement. The spectra of power via frequency of detected PD signals are analyzed and compared. The experimental results show that the Hilbert fractal antenna and small loop antenna are qualified for PD online UHF monitoring.
基金Supported by the National Natural Science Foundation of China, the Northeastern Electric Power Corp. (Group) (No. 59637200), and the National Foundation of USA
文摘This paper introduces a computerized on-line partial discharge (PD) monitoring and diagnostic system for transformers. The system, which is already in use in a power station, uses wide-band active transducers and a data acquisition unit with modularized and exchangeable components. The system software is a power equipment monitoring and diagnostic system, which is based on the component object model, and was developed for monitoring multiple parameters in multiple power supply systems. The statistical characteristics of PDs in power transformers were studied using 7 experimental models for simulating PDs in transformers and 3 models for simulating interfering discharges in air. The discharge features were analyzed using a 3-D pattern chart with a three-layer back-propagation artificial neural network used to recognize the patterns. The results show that PDs in air and oil can be distinguished. The model can be used for interference rejection on-line monitoring of partial discharge in transformers.
文摘特高压直流GIL运行可靠性取决于内绝缘设计的可靠性。此外,导电元件直流电流密度的取值、弹簧触头的定位设计、GIL各元件中的绝缘件与金具连接处的楔形气隙的处理以及母线中支撑件的结构设计细节,都会对产品运行可靠性产生重大影响,不能忽视。对于运行环境十分严酷的UHV DC GIL为保证内绝缘工作可靠性和减少气体维护工作量,文中还提出了高气密性结构设计。为适应-50℃低温运行要求,产品选用了液化温度很低的N_(2)/SF_(6)混合气体,对两种气体的配比,压力特性和绝缘特性进行了讨论与计算。还有产品的局放、气体密度及微水含量的监视系统的可靠性设计,都会对产品运行可靠性产生直接影响。文中对上述问题的研究成果作了介绍,可供高压直流产品设计使用。对其中未解的新技术如基于冷镜露点测试原理、微机电技术制作的智能气体湿度和密度监测装置、高压直流复合绝缘套管伞面局放起始场强提出了研究方案。文中提出的诸多GIL运行可靠性设计要点,对于其他超/特高压直流气体绝缘电器可参考选用。