The surface tension of molten tin was determined by a set of self-developed digital equipment with sessile drop method at oxygen partial pressure of 1.0×10 -6MPa under different temperatures, and the dependence...The surface tension of molten tin was determined by a set of self-developed digital equipment with sessile drop method at oxygen partial pressure of 1.0×10 -6MPa under different temperatures, and the dependence of surface tension of molten tin on temperature was also discussed. The emphasis was placed on the comparison of surface tension of the same molten tin sample measured by using different equipments with sessile drop method. Results of the comparison indicate that the measurement results with sessile drop method under the approximate experimental conditions are coincident, and the self-developed digital equipment for surface tension measurement has higher stability and accuracy. The relationships of surface tension of molten tin and its temperature coefficient with temperature and oxygen partial pressure were also elucidated from the thermodynamic equilibrium analysis.展开更多
According to energy partition principle,we have derived a generalized formula used to calculate the radiation effi-ciency.It overcomes the numerical errors involved in the estimation of radiation efficiency caused by ...According to energy partition principle,we have derived a generalized formula used to calculate the radiation effi-ciency.It overcomes the numerical errors involved in the estimation of radiation efficiency caused by the uncer-tainties owe to the different frictional mechanisms which is used to describe the earthquake faulting.Using real seismic data published in the previous studies,we have recalculated the radiation efficiency with associated to the different frictional mechanisms,and compared with previous results lack of consideration of frictional mechanism.The results indicate that,based on the new formula,the radiation efficiency we have estimated is always less than 1,and the unphysical conclusion of radiation efficiency greater than 1 is avoided completely.展开更多
文摘The surface tension of molten tin was determined by a set of self-developed digital equipment with sessile drop method at oxygen partial pressure of 1.0×10 -6MPa under different temperatures, and the dependence of surface tension of molten tin on temperature was also discussed. The emphasis was placed on the comparison of surface tension of the same molten tin sample measured by using different equipments with sessile drop method. Results of the comparison indicate that the measurement results with sessile drop method under the approximate experimental conditions are coincident, and the self-developed digital equipment for surface tension measurement has higher stability and accuracy. The relationships of surface tension of molten tin and its temperature coefficient with temperature and oxygen partial pressure were also elucidated from the thermodynamic equilibrium analysis.
基金National Natural Science Foundation of China (40574022)Special Research Project of Welfare Institute (ZDJ2007-1)One Hundred Talent Project of Chinese Academy of Sciences.
文摘According to energy partition principle,we have derived a generalized formula used to calculate the radiation effi-ciency.It overcomes the numerical errors involved in the estimation of radiation efficiency caused by the uncer-tainties owe to the different frictional mechanisms which is used to describe the earthquake faulting.Using real seismic data published in the previous studies,we have recalculated the radiation efficiency with associated to the different frictional mechanisms,and compared with previous results lack of consideration of frictional mechanism.The results indicate that,based on the new formula,the radiation efficiency we have estimated is always less than 1,and the unphysical conclusion of radiation efficiency greater than 1 is avoided completely.