Particulates generated from electrode erosion in gas spark gap is inevitable and may initiate selfbreakdown behavior with high risk.Traditionally,this problem is addressed by empirical method qualitatively.To push thi...Particulates generated from electrode erosion in gas spark gap is inevitable and may initiate selfbreakdown behavior with high risk.Traditionally,this problem is addressed by empirical method qualitatively.To push this old problem forward,this paper conducts laser confocal microscopy measurement of eroded surface and a statistical method is introduced to obtain visualization of particulates distribution from electrode erosion after different shots.This method allows dense particulates to be classified with their heights in z direction and scattered figures of particulates within certain height range are obtained.Results indicate that the higher-than-10 μm particulates start to emerge after 200 discharge shots and particulates number has a waved radial distribution with a 0.5 mm wide deposition zone.Based on these quantitative results,the risk of reignition and field-distortion failure that are triggered by particulates can be assessed.展开更多
Household air pollution is considered to be among the top environmental risks in China.To examine the performance of improved stoves for reduction of indoor particulate matter(PM) emission and exposure in rural hous...Household air pollution is considered to be among the top environmental risks in China.To examine the performance of improved stoves for reduction of indoor particulate matter(PM) emission and exposure in rural households, individual inhalation exposure to size-resolved PM was investigated using personal portable samplers carried by residents using wood gasifier stoves or improved coal stoves in a rural county in Central China.Concentrations of PM with different sizes in stationary indoor and outdoor air were also monitored at paired sites. The stationary concentrations of size-resolved PM in indoor air were greater than those in outdoor air, especially finer particles PM0.25. The daily averaged exposure concentrations of PM0.25, PM1.0, PM2.5 and total suspended particle for all the surveyed residents were 74.4 ± 41.1, 159.3 ± 74.3, 176.7 ± 78.1 and 217.9 ± 78.1 μg/m3,respectively. Even using the improved stoves, the individual exposure to indoor PM far exceeded the air quality guideline by WHO at 25 μg/m3. Submicron particles PM1.0 were the dominant PM fraction for personal exposure and indoor and outdoor air. Personal exposure exhibited a closer correlation with indoor PM concentrations than that for outdoor concentrations. Both inhalation exposure and indoor air PM concentrations in the rural households with gasifier firewood stoves were evidently lower than the reported results using traditional firewood stoves. However, local governments in the studied rural areas should exercise caution when widely and hastily promoting gasifier firewood stoves in place of improved coal stoves, due to the higher PM levels in indoor and outdoor air and personal inhaled exposure.展开更多
Industrial coal-fired boiler is an important air pollutant emission source in China. The chain-grate boiler is the most extensively used type of industrial coal-fired boiler. An electrical low-pressure impactor, and a...Industrial coal-fired boiler is an important air pollutant emission source in China. The chain-grate boiler is the most extensively used type of industrial coal-fired boiler. An electrical low-pressure impactor, and a Dekati? Low Pressure Impactor were applied to determine mass and number size distributions of PM10 at the inlet and the outlet of the particulate emission control devices at six coalfired chain-grate boilers. The mass size distribution of PM10 generated from coal-fired chain-grate boilers generally displays a bimodal distribution that contains a submicron mode and a coarse mode. The PM in the submicron mode for burning with raw coal contributes to 33% ± 10 % of PM10 emissions, much higher than those for pulverized boilers. And the PM in the submicron mode for burning with briquette contributes up to 86 % of PM10 emissions. Multiclones and scrubbers are not efficient for controlling PM10 emission. Their average collection efficiencies for sub-micron particle and super-micron particle are 34% and 78%, respectively. Operating conditions of industrial steam boilers have influence on PM generation. Peak of the submicron mode during normal operation period is larger than the start-up period.展开更多
基金supported by Science & Development Foundation of CAEP(Grant No.2015B0402085)
文摘Particulates generated from electrode erosion in gas spark gap is inevitable and may initiate selfbreakdown behavior with high risk.Traditionally,this problem is addressed by empirical method qualitatively.To push this old problem forward,this paper conducts laser confocal microscopy measurement of eroded surface and a statistical method is introduced to obtain visualization of particulates distribution from electrode erosion after different shots.This method allows dense particulates to be classified with their heights in z direction and scattered figures of particulates within certain height range are obtained.Results indicate that the higher-than-10 μm particulates start to emerge after 200 discharge shots and particulates number has a waved radial distribution with a 0.5 mm wide deposition zone.Based on these quantitative results,the risk of reignition and field-distortion failure that are triggered by particulates can be assessed.
基金Natural Science Foundation Committee of China(No.41390240,41130754,and 41161160559)National Basic Research Program of China(No.2014CB441101)+1 种基金Science&Technology Basic Special Fund(No.2013FY111100-04)Global Alliance for Clean Cookstoves under PR-15-39809
文摘Household air pollution is considered to be among the top environmental risks in China.To examine the performance of improved stoves for reduction of indoor particulate matter(PM) emission and exposure in rural households, individual inhalation exposure to size-resolved PM was investigated using personal portable samplers carried by residents using wood gasifier stoves or improved coal stoves in a rural county in Central China.Concentrations of PM with different sizes in stationary indoor and outdoor air were also monitored at paired sites. The stationary concentrations of size-resolved PM in indoor air were greater than those in outdoor air, especially finer particles PM0.25. The daily averaged exposure concentrations of PM0.25, PM1.0, PM2.5 and total suspended particle for all the surveyed residents were 74.4 ± 41.1, 159.3 ± 74.3, 176.7 ± 78.1 and 217.9 ± 78.1 μg/m3,respectively. Even using the improved stoves, the individual exposure to indoor PM far exceeded the air quality guideline by WHO at 25 μg/m3. Submicron particles PM1.0 were the dominant PM fraction for personal exposure and indoor and outdoor air. Personal exposure exhibited a closer correlation with indoor PM concentrations than that for outdoor concentrations. Both inhalation exposure and indoor air PM concentrations in the rural households with gasifier firewood stoves were evidently lower than the reported results using traditional firewood stoves. However, local governments in the studied rural areas should exercise caution when widely and hastily promoting gasifier firewood stoves in place of improved coal stoves, due to the higher PM levels in indoor and outdoor air and personal inhaled exposure.
基金Acknowledgements This study was supported by the National Natural Science Foundation of China (Grant Nos. 41275121 and 41575119) and the National Key Basic Research and Development Program of China (No. 2013CB228505) and Beijing Municipal Science & Technology Commission (Grant No. Z161100000716004).
文摘Industrial coal-fired boiler is an important air pollutant emission source in China. The chain-grate boiler is the most extensively used type of industrial coal-fired boiler. An electrical low-pressure impactor, and a Dekati? Low Pressure Impactor were applied to determine mass and number size distributions of PM10 at the inlet and the outlet of the particulate emission control devices at six coalfired chain-grate boilers. The mass size distribution of PM10 generated from coal-fired chain-grate boilers generally displays a bimodal distribution that contains a submicron mode and a coarse mode. The PM in the submicron mode for burning with raw coal contributes to 33% ± 10 % of PM10 emissions, much higher than those for pulverized boilers. And the PM in the submicron mode for burning with briquette contributes up to 86 % of PM10 emissions. Multiclones and scrubbers are not efficient for controlling PM10 emission. Their average collection efficiencies for sub-micron particle and super-micron particle are 34% and 78%, respectively. Operating conditions of industrial steam boilers have influence on PM generation. Peak of the submicron mode during normal operation period is larger than the start-up period.