The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo...The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.展开更多
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co...Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.展开更多
Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enri...Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.展开更多
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog...An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.展开更多
To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right...To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats.展开更多
In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Pr...In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls.展开更多
[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and ...[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate.展开更多
Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample...Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyacrylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×10^-9 to 3.1×10^- 8g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 lag/L. Conelusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.展开更多
Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is ...Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound.In order to give full play to the advantages of Chinese herbal compound,modern scientific and technological is used to research of Chinese herbal compound,especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS),because it is high sensitive,rapid,and obtain more information.It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound,and endow traditional Chinese medicine with modern scientific connotation.展开更多
The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under follo...The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray.展开更多
A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by o...A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by one-fold volume of methanol and acetonitrile to remove the interference proteins. A reverse phase column of SHIM- PACK VP-ODS (150 mm × 4.6 mm, 5.0 μm) was used to separate 4-O-methylhonokiol in the plasma samples. The detection limit of 4-O-methylhonokiol was 0.2 μg/L and the linear range was 0. 012 - 1. 536 mg/L. The good extraction recoveries were obtained for the spiked samples (84.7%, 89.3% and 87.7% for low, middle and high concentrations of added standards, respectively). The relative standard deviation of intra-day and inter-day precisions was in the range from 0.6% to 13.5%. The pharmacokinetic study of 4-O-methylhonokiol was made and the results from the plasmaconcentration curve of 4-0-methylhonokiol showed a two-apartment open model. This work developed a sensitive, stable and rapid HPLC method for the determination of 4-O-methylhonokiol and the developed method has been successfully applied to a pharmacokinetic study of 4-O-methylhonokiol.展开更多
Modification was made on the reversed-phase high performance liquid chromatography(RP-HPLC)with Yue et al's method as a base.The modified RP-HPLC was used to detect leukotriene B_4(LTB_4)and 5-hydroxyeicosatetraen...Modification was made on the reversed-phase high performance liquid chromatography(RP-HPLC)with Yue et al's method as a base.The modified RP-HPLC was used to detect leukotriene B_4(LTB_4)and 5-hydroxyeicosatetraenoic acid(5-HETE).It was found that the modified method has the merits of simpler procedures,shorter testing time and more satisfactory efficacy.展开更多
A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chine...A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk.展开更多
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato...A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.展开更多
Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These...Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.展开更多
A method of 24 allergens determination in cosmetics were established with high performance liquid chromatography tandem mass spectrometry. The targeted compounds were extracted with acetonitrile and determined with LC...A method of 24 allergens determination in cosmetics were established with high performance liquid chromatography tandem mass spectrometry. The targeted compounds were extracted with acetonitrile and determined with LC-MS/MS (MRM mode) with external method. The linearity between concentrations and peak area ratio was obtained from 1.0~5.0 mg/L. The limits of detection were 1.0 mg/L for the instrument and 5.0 mg/kg for the method respectively. The LOQ was 15.0 mg/L. The average recoveries of 24 allergens were between 85.9% and 110.0% at spiked levels of 5, 10 and 20 mg/kg with relative standard derivation (RSDs) of 5.5%~12.0%(n=10). The method could be used as a reliable means for simultaneous quantitative determination of allergens in cosmetics.展开更多
Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify ...Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify and quantify DSP toxins in shellfish. This new methodology could facilitate DSP monitoring and create a means of rapidly responding to incidents threatening public health. In the last years there were different analytical methods for DSP, such as mouse bioassay and LC-FLD. With the development of instrument, Liquid chromatography-mass spectrometry was substituted for other analytical methods with its good sensitivity and selectivity and without derivatization for the determination of DSP. In this report, a high performance liquid chromatogra-phytandem mass spectrometric(HPLC-MS/MS)method was developed for the simultaneous determination of okadaic acid (OA) and dinophysistoxins(DTX1) in Sinonovacula constricta. Optimization of pretreatment experiment was carried out to maximize recoveries and the effectiveness. The analytes were determined under multi-reactions monitoring (MRM) scan type with tandem mass analyzer using negative ion electrospray ionization (-ESI) mode .Finally, the detection and identification of OA and DTX-1 were based upon their retention times (RT) and the fragmentation patterns of their mass spectra. The method of LOQ for the two poisons was 0.02 mg·kg-1.The real sample test showed that this method could be used for sensitive, fast, and accurate determination of the two diarrheic shellfish poisons in shellfish.展开更多
A method using high performance liquid chromatography(HPLC)was developed for the s imultaneous determination of 13 preservatives(levulinic acid,p-hydroxyacetophenone,raspberry ketone,p-anisic acid,caprylhydroxamic aci...A method using high performance liquid chromatography(HPLC)was developed for the s imultaneous determination of 13 preservatives(levulinic acid,p-hydroxyacetophenone,raspberry ketone,p-anisic acid,caprylhydroxamic acid,hydroxyethoxyphenyl butanone,methylisothiazolinone,phenoxyethanol,b e n z oic acid,methylparaben,chlorphenesin,dehydroacetic acid,and 5-bromo-5-nitro-1,3-dioxane)in cosmetics.Different types of samples were ultrasonically extracted by methanol,then the separation of 13 preservatives was carried out on a column of Agilent ZORBAX Eclipse XDB-C18(250 mm×4.6 mm,5μm)by gradient elution at a flow rate of 1.0 mL/min,using 0.1%phosphoric acid solution and acetonitrile as mobile phases.The column temperature was 30℃,and the detection was completed by a diode array detector with the wavelengths at 275,230 and 210 nm.Suspected positive samples were further confirmed by liquid chromatography-tandem mass spectrometry or gas chromatography-mass spectrometry.The linear regression analysis data shows good linearity for 13 preservatives in the respective mass concentration range,with their correlation coefficients(r)greater than 0.9998.The limits of detection(LODs)and limits of quantitation(LOQs)of the method are in the ranges of 0.4-100.0 mg/kg and 1.2-250.0 mg/kg,respectively.At three spiked levels,the average recoveries for 13 target compounds in three kinds of matrix samples are within 84.0%-115.4%,and the relative standard deviations(RSD)are within 0.5%-4.8%(n=6).This method is convenient,efficient,and precise,which can be used for qualitative and quantitative analysis of common preservatives in daily cosmetics.展开更多
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc...In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.展开更多
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi...The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.展开更多
文摘The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.
文摘Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.
基金Project supported by the National Natural Science Foundation of China (No.20437020)Major Research Program of Chinese Academy of Sciences (No.KZCX3-SW-432).
文摘Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.
基金Supported by the Science and Technology Plan of Liaoning Province, China(No.2006226002)the Project of the Doctor Fund of Hebei University of Science and Technology, China(No.005121)
文摘An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.
基金This work was supported by the National Natural Science Foundation of China (Grant No. 30560171).
文摘To determine dopamine and its metabolites during in vivo cerebral microdialysis by routine high performance liquid chromatography with electrochemical detection. Methods Microdialysis probes were placed into the right striatum of Wistar rat brains and perfused with Ringer's solution at a rate of 1.5 pL/min. A reverse phase HPLC with electrochemistry was used to assay DA, DOPAC, and HVA after cerebral microdialysates were collected every 20 minutes from awake and freely moving rats. In order to identify the reliability of this method, its selectivity, linear range, precision and accuracy were tested and the contents of DA, DOPAC, and HVA in rat microdialysates were determined. Results The standard curve was in good linear at the concentration ranging from 74 nmol/L to 1.5 pmol/L for DOPAC (r^2= 0.9996), from 66 nmol/L to 1.3 gmol/L for DA (r^2=l.0000) and from 69 nmol/L to 1.4 pmol/L for HVA (r^2=0.9992). The recovery of DOPAC (0.30, 0.77, 1.49 gmol/L), DA (0,26, 0.69, 1.32 gmol/L), and HVA (0.27, 0.71, 1.37 gmol/L) was 82.00±1.70%, 104.00±4.00%, 98.70±3.10%; 92.30± 1.50%, 105.30±2.30%, 108.00±2.00%; 80.00±7.80%, 107.69±8.00%, and 108.66±3.10%, respectively at each concentration. Their intra-day RSD was 3.3%, 3.4%, and 2.5%, and inter-day RSD was 4.2%, 2.3%, and 5.6%, respectively. The mean extracellular concentrations of DOPAC, DA, and HVA in rat brain microdialysates were 10.7, 2.4, and 9.2 gmol/L (n=6), respectively. Conclusion The findings of our study suggested that the simple, accurate and stable method can be applied to basic researches of diseases related to monoamines neurotransmitters by cerebral microdialysis in rats.
文摘In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls.
文摘[Objective]The paper was to establish a method for determining AF and AFG in red ginseng.[Method]A new simple,rapid and sensitive method for simultaneous determination of two amadori compounds,arginyl-fructose(AF)and arginyl-fructosyl-glucose(AFG),in extracts of three kinds of ginseng preparations was developed and validated using high performance liquid chromatography with evaporative light scattering detector(HPLC-ELSD).Two target analytes were efficiently separated by Prevail CTM18 column(4.6 mm×250 mm,5μm)at the flow rate of 0.8 mL/min within 15 min of single chromatographic run.[Result]Under optimized conditions,the detection limits were 0.015 and 0.02 mg/mL for AF and AFG,respectively.Calibration curves of peak area for two analytes were linear over three orders of magnitude with the correlation coefficients greater than 0.999.The average recoveries,precision,reproducibility and stability for two analytes(AF and AFG)were 99.5% and 100.9%,0.43% and 0.47%,0.46% and 0.43%,0.41% and 0.49%,respectively.[Conclusion]This method was successfully applied for quantifying AF and AFG in red ginseng and the method was efficient,sensitive and accurate.
文摘Objective To determine residual acrylamide in medical polyacrylamide hydrogel by high performance liquid chromatography tandem mass spectroscopy (HPLC-MS). Methods After 13C3 labeled acrylamide was added, the sample was extracted with water and then cleaned up with ExtrelutTM 20. The polyacrylamide hydrogel sample and 20 clinical cases were analyzed by HPLC-MS/MS and isotope dilution quantifying technique in selected reaction monitoring (SRM) mode. Results Acrylamide was separated from polyacrylamide hydrogel. The concentration of acrylamide in polyacrylamide hydrogel ranged from 3.9×10^-9 to 3.1×10^- 8g/L in the 20 clinical cases. The peak area was favorable linear and the range was up to 3 000 μg/L. The recovery rate was 103.1% with a relative standard deviation (RSD) of 6.20%, when the mark level was 50 lag/L. Conelusion HPLC-MS is a rapid, accurate, and sensitive method for the determination of residual acrylamide in medical polyacrylamide hydrogel.
文摘Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound.In order to give full play to the advantages of Chinese herbal compound,modern scientific and technological is used to research of Chinese herbal compound,especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS),because it is high sensitive,rapid,and obtain more information.It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound,and endow traditional Chinese medicine with modern scientific connotation.
基金Sponsored by the Basic Research Funds of Beijing Institute of Technology (20081642007)
文摘The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray.
基金supported by Xi'an Jiaotong University(No.01380011)
文摘A novel high performance liquid chromatographic method was developed for the determination of 4-O- methylhonokiol in rabbit plasma and was applied to its pharmacokinetic investigation. Plasma samples were treated by one-fold volume of methanol and acetonitrile to remove the interference proteins. A reverse phase column of SHIM- PACK VP-ODS (150 mm × 4.6 mm, 5.0 μm) was used to separate 4-O-methylhonokiol in the plasma samples. The detection limit of 4-O-methylhonokiol was 0.2 μg/L and the linear range was 0. 012 - 1. 536 mg/L. The good extraction recoveries were obtained for the spiked samples (84.7%, 89.3% and 87.7% for low, middle and high concentrations of added standards, respectively). The relative standard deviation of intra-day and inter-day precisions was in the range from 0.6% to 13.5%. The pharmacokinetic study of 4-O-methylhonokiol was made and the results from the plasmaconcentration curve of 4-0-methylhonokiol showed a two-apartment open model. This work developed a sensitive, stable and rapid HPLC method for the determination of 4-O-methylhonokiol and the developed method has been successfully applied to a pharmacokinetic study of 4-O-methylhonokiol.
文摘Modification was made on the reversed-phase high performance liquid chromatography(RP-HPLC)with Yue et al's method as a base.The modified RP-HPLC was used to detect leukotriene B_4(LTB_4)and 5-hydroxyeicosatetraenoic acid(5-HETE).It was found that the modified method has the merits of simpler procedures,shorter testing time and more satisfactory efficacy.
基金Education Ministy Foundation for Chinese Returned Scholars and Nature Science Foundation of Hubeiprovince!98J054
文摘A flow injection (FI) micro-column system coupled with high performance liquid chromatography (HPLC) was proposed for the pre-separation and determination of active organic component (ecdysterone) in traditional Chinese medicine, Loulu. The factors influencing separation performance were investigated and optimized. Under the optimal conditions, the contents of ecdysterone in Loulu were determined by HPLC system using MeOH-H_2O (40: 60,V/V) as the mobile phase at a flow rate of 1. 0 mL/min. The calibration curve was linear in the range of 0. 5~ 100 mg/L of ecdysterone concentrations. The detection limit of the analyte was 0. 11mol/L(3) with a precision of 0. 38% RSD (n=7 f c= 10. 0 mg/L). The average recovery of the method was 98. 7%. The proposed method has been applied to determine ecdysterone in practical samples, and the determined values by both external standard method and standard addition method were in good agreement. Compared to the traditional solid extraction method, the system proposed has the advantages of simple procedure, good reproducibility, minimum volume requirement, reduction of matrix interference and low contamination risk.
文摘A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.
基金Supported by grants of the National Institute of General Medical Sciences,National Institutes of Health(GM-48364),and the Materials Sciences and Engineering Division of the U.S.Department of Energy(DE-AC02-05CH11231).
文摘Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.
基金supported by The National Natural Science Foundation of China(Grant No.31360447)The National Natural Science Foundation of Hainan Province(Grant No.20162036)
文摘A method of 24 allergens determination in cosmetics were established with high performance liquid chromatography tandem mass spectrometry. The targeted compounds were extracted with acetonitrile and determined with LC-MS/MS (MRM mode) with external method. The linearity between concentrations and peak area ratio was obtained from 1.0~5.0 mg/L. The limits of detection were 1.0 mg/L for the instrument and 5.0 mg/kg for the method respectively. The LOQ was 15.0 mg/L. The average recoveries of 24 allergens were between 85.9% and 110.0% at spiked levels of 5, 10 and 20 mg/kg with relative standard derivation (RSDs) of 5.5%~12.0%(n=10). The method could be used as a reliable means for simultaneous quantitative determination of allergens in cosmetics.
文摘Consumption of shellfish contaminated with algal toxins produced by marine dinoflagellates can lead to diarrhetic shellfish poisoning (DSP). It was therefore essential that there are analytical techniques to identify and quantify DSP toxins in shellfish. This new methodology could facilitate DSP monitoring and create a means of rapidly responding to incidents threatening public health. In the last years there were different analytical methods for DSP, such as mouse bioassay and LC-FLD. With the development of instrument, Liquid chromatography-mass spectrometry was substituted for other analytical methods with its good sensitivity and selectivity and without derivatization for the determination of DSP. In this report, a high performance liquid chromatogra-phytandem mass spectrometric(HPLC-MS/MS)method was developed for the simultaneous determination of okadaic acid (OA) and dinophysistoxins(DTX1) in Sinonovacula constricta. Optimization of pretreatment experiment was carried out to maximize recoveries and the effectiveness. The analytes were determined under multi-reactions monitoring (MRM) scan type with tandem mass analyzer using negative ion electrospray ionization (-ESI) mode .Finally, the detection and identification of OA and DTX-1 were based upon their retention times (RT) and the fragmentation patterns of their mass spectra. The method of LOQ for the two poisons was 0.02 mg·kg-1.The real sample test showed that this method could be used for sensitive, fast, and accurate determination of the two diarrheic shellfish poisons in shellfish.
文摘A method using high performance liquid chromatography(HPLC)was developed for the s imultaneous determination of 13 preservatives(levulinic acid,p-hydroxyacetophenone,raspberry ketone,p-anisic acid,caprylhydroxamic acid,hydroxyethoxyphenyl butanone,methylisothiazolinone,phenoxyethanol,b e n z oic acid,methylparaben,chlorphenesin,dehydroacetic acid,and 5-bromo-5-nitro-1,3-dioxane)in cosmetics.Different types of samples were ultrasonically extracted by methanol,then the separation of 13 preservatives was carried out on a column of Agilent ZORBAX Eclipse XDB-C18(250 mm×4.6 mm,5μm)by gradient elution at a flow rate of 1.0 mL/min,using 0.1%phosphoric acid solution and acetonitrile as mobile phases.The column temperature was 30℃,and the detection was completed by a diode array detector with the wavelengths at 275,230 and 210 nm.Suspected positive samples were further confirmed by liquid chromatography-tandem mass spectrometry or gas chromatography-mass spectrometry.The linear regression analysis data shows good linearity for 13 preservatives in the respective mass concentration range,with their correlation coefficients(r)greater than 0.9998.The limits of detection(LODs)and limits of quantitation(LOQs)of the method are in the ranges of 0.4-100.0 mg/kg and 1.2-250.0 mg/kg,respectively.At three spiked levels,the average recoveries for 13 target compounds in three kinds of matrix samples are within 84.0%-115.4%,and the relative standard deviations(RSD)are within 0.5%-4.8%(n=6).This method is convenient,efficient,and precise,which can be used for qualitative and quantitative analysis of common preservatives in daily cosmetics.
文摘In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.
文摘The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.