期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
PENETRATION RATE MEASUREMENT AND ITS INSTRUMENT DESIGN
1
作者 Qiu Zhenyuan 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 1991年第1期14-19,共6页
The practical method for precise penetration rate measurement in a short time and the instrument design have been specially discussed in this paper.Considering the defects of the penetration rate meters available,via ... The practical method for precise penetration rate measurement in a short time and the instrument design have been specially discussed in this paper.Considering the defects of the penetration rate meters available,via the balanced design in consideration of service life,costs,accuracy and reliability,a kind of penetration rate meter has been put forward.The meter consists of a magnetic clutch,a gear box and a raster disk system to pick up the signal.The meter has the following advantages-it might measure a low speed with higher accura-cy,it could disengage automatically without being divorced from the driving device during tripping rods at high speed,it has a circuit of rotary direction discrimination and of repeated counting prevention so as to eU-minate error caused by rod vibration. 展开更多
关键词 penetration rate measurement instrument design magnetic clutch gear box raster disk
下载PDF
Measurement of optical penetration depth and refractive index of human tissue 被引量:14
2
作者 谢树森 李晖 李步洪 《Chinese Optics Letters》 SCIE EI CAS CSCD 2003年第1期44-46,共3页
Experimental techniques for measurement of optical penetration depth and refractive index of human tissue are presented, respectively. Optical penetration depth can be obtained from the measurement of the relative flu... Experimental techniques for measurement of optical penetration depth and refractive index of human tissue are presented, respectively. Optical penetration depth can be obtained from the measurement of the relative fluencc-depth distribution inside the target tissue. The depth of normal and carcinomatous human lung tissues irradiated with the wavelengths of 406.7, 632.8 and 674.4 nm in vitro are respectively determined. In addition, a novel simple method based on total internal reflection for measuring the refractive index of biotissue in vivo is developed, and the refractive indices of skin from people of different age, sex and skin color are measured. Their refractive indices are almost same and the average is 1.533. 展开更多
关键词 of in AS IS measurement of optical penetration depth and refractive index of human tissue
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部