Performance analysis of ammonia-water absorption/compression combined refrigeration cycle 被引量:1
1
作者 鲍帅阳 杜垲 +2 位作者 蔡星辰 牛晓峰 武云龙 《Journal of Southeast University(English Edition)》 EI CAS 2014年第1期60-67,共8页
In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis ... In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis and calculations on two combination ways by adding the compressor in the high-pressure area and in the low-pressure area are conducted respectively.The effects of several factors including the evaporation temperature Te heat-source temperature Th as well as the cooling water temperature Tw on the equivalent heat consumption in compression qCW heat consumption in absorption qG and the system coefficient of performance COP are analyzed under the two combination configurations.The results show that the effect of the equivalent heat consumption in compression on the COP is less than that of the heat consumption in absorption.Besides the compressor set in the high-pressure area uses more energy than that in the low-pressure area. Moreover the compressor in the low-pressure area is superior to that in the high-pressure area with respect to the COP. Under the given intermediate pressure there is an optimum heat-source temperature corresponding to the maximum COP of the AWA/CCR cycle. 展开更多
关键词 AMMONIA-WATER ABSORPTION compression refrigeration combined refrigeration cycle coefficient of performance COP
下载PDF
Performance optimization analysis of a thermoelectric refrigerator with two resonances 被引量:4
2
作者 罗小光 何济洲 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第3期110-114,共5页
Based on electron transport theory, the performance of kx and kr filtered thermoelectric refrigerators with two resonances are studied in this paper. The performance characteristic curves between the cooling rate and ... Based on electron transport theory, the performance of kx and kr filtered thermoelectric refrigerators with two resonances are studied in this paper. The performance characteristic curves between the cooling rate and the coefficient of performance are plotted by numerical calculation. It is shown that the maximum cooling rate of the thermoelectric refrigerator with two resonances increases but the maximum coefficient of performance decreases compared with those with one resonance. No matter which resonance mechanism is used (kx or kr filtered), the cooling rate and the performance coefficient of the kr filtered refrigerator are much better than those of the kx filtered one. 展开更多
关键词 thermoelectric refrigerator two resonances cooling rate coefficient of performance
下载PDF
Analysis of performance and optimum configuration of two-stage semiconductor thermoelectric module 被引量:4
3
作者 李开振 梁瑞生 魏正军 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第4期1349-1354,共6页
In this paper, the theoretical analysis and simulating calculation were conducted for a basic two-stage semiconductor thermoelectric module, which contains one thermocouple in the second stage and several thermocouple... In this paper, the theoretical analysis and simulating calculation were conducted for a basic two-stage semiconductor thermoelectric module, which contains one thermocouple in the second stage and several thermocouples in the first stage. The study focused on the configuration of the two-stage semiconductor thermoelectric cooler, especially investigating the influences of some parameters, such as the current I1 of the first stage, the area A1 of every thermocouple and the number n of thermocouples in the first stage, on the cooling performance of the module. The obtained results of analysis indicate that changing the current I1 of the first stage, the area A1 of thermocouples and the number n of thermocouples in the first stage can improve the cooling performance of the module. These results can be used to optimize the configuration of the two-stage semiconductor thermoelectric module and provide guides for the design and application of thermoelectric cooler. 展开更多
关键词 thermocouples coefficient of performance cooling capacity
下载PDF
Exploring heating performance of gas engine heat pump with heat recovery 被引量:3
4
作者 董付江 刘凤国 +2 位作者 李先庭 尤学一 赵冬芳 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期1931-1936,共6页
In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1... In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 ℃) and condenser water inlet temperature(30-50℃). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 ℃ to 17.8 ℃, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 ℃ to 50 ℃. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature. 展开更多
关键词 gas engine heat pump coefficient of performance primary energy ratio heating mode heat recovery
下载PDF
Experimental Performance of Moderate and High Temperature Heat Pump Charged with Refrigerant Mixture BY-3 被引量:3
5
作者 陈成敏 张于峰 +4 位作者 邓娜 马洪亭 张彦所 马丽筠 胡晓微 《Transactions of Tianjin University》 EI CAS 2011年第5期386-390,共5页
Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe... Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained. 展开更多
关键词 moderate and high temperature heat pump refrigerant mixture SINGLE-STAGE compression heat pump system coefficient of performance
下载PDF
Experimental Investigation on the Performance of Heat Pump Operating with Copper and Alumina Nanofluids 被引量:1
6
作者 Faizan Ahmed Waqar Ahmed Khan Jamal Nayfeh 《Computers, Materials & Continua》 SCIE EI 2021年第3期2843-2856,共14页
In the present study,an attempt ismade to enhance the performance of heat pump by utilizing two types of nanofluids namely,copper and alumina nanofluids.These nanofluids were employed around the evaporator coil of the... In the present study,an attempt ismade to enhance the performance of heat pump by utilizing two types of nanofluids namely,copper and alumina nanofluids.These nanofluids were employed around the evaporator coil of the heat pump.The nanofluids were used to enhance the heat input to the system by means of providing an external jacket around the evaporator coil.Both the nanofluids were prepared in three volume fractions 1%,2%and 5%.Water was chosen as the base fluid.The performance of the heat pump was assessed by calculating the coefficient of performance of the system when it was operated with and without nanofluid jacket.A significant enhancement in the coefficient of performance was noticed when copper and alumina nanofluids were employed in the system.Also,the coefficient of performance was found to have a direct relationship with the tested volume fractions.For the highest volume fraction of 5%,the performance of the heat pump was found to enhance by 23%with alumina nanofluid,while for copper nanofluid,a very significant enhancement in performance by 72%was observed.Thus,utilizing of nanofluids in heat pumps can be very beneficial towards performance enhancement and the idea can also be extended to other thermal systems such as steam power plant,automobile radiator,industrial heat exchangers and refrigeration systems. 展开更多
关键词 NANOPARTICLES copper nanofluid alumina nanofluid heat pump coefficient of performance
下载PDF
High Performance ZrNbAl Alloy with Low Thermal Expansion Coefficient 被引量:1
7
作者 Yun-Kai Zhou Xing Zhang +2 位作者 Shu-Guang Liu Ming-Zhen Ma Ri-Ping Liu 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第8期54-57,共4页
Thermal expansion is a common phenomenon in both metals and alloys, which is important for metallic material applications in modern industry, especially in nuclear and aerospace industries. A lower thermal expansion c... Thermal expansion is a common phenomenon in both metals and alloys, which is important for metallic material applications in modern industry, especially in nuclear and aerospace industries. A lower thermal expansion coefficient may cause lower thermal stress and higher accuracy. A new Zr-based alloy is developed and presented.The XRD diffraction results demonstrate that only a close-packed hexagonal phase(α or α' phase) exists in the microstructure. The thermal expansion and mechanical properties are studied. According to the experimental results, the new Zr-based alloy presents a low thermal expansion coefficient and good mechanical properties.Also,its thermal expansion coefficient is stable through solution treatment. 展开更多
关键词 ZR High performance ZrNbAl Alloy with Low Thermal Expansion Coefficient XRD
下载PDF
Numerical Simulation and Performance Assessment of a Nanoparticle Enhanced Vapour Compression Refrigeration System 被引量:1
8
作者 Moradeyo K. Odunfa Oluwaseyi D. Oseni 《Journal of Power and Energy Engineering》 2021年第11期33-49,共17页
Cooling in industrial production and refrigeration of perishable and</span><span style="font-size:10.0pt;font-family:""> non-</span><span style="font-size:10.0pt;font-family:&q... Cooling in industrial production and refrigeration of perishable and</span><span style="font-size:10.0pt;font-family:""> non-</span><span style="font-size:10.0pt;font-family:""> </span><span style="font-size:10.0pt;font-family:"">perishable products is common practice throughout the world. Research studies have been conducted both experimentally and numerically to simulate Vapor Compression Refrigeration System (VCRS) and its performance respectively, however, experimental procedure often seems to be expensive and time-consuming to carry out due to the function of many variables. This study was therefore designed to numerically simulate the performance assessment of a nanoparticle enhanced VCRS. A numerical model of a vapor compression refrigeration system was developed using standard refrigeration equations on each of the major components of the refrigeration system such as compressor, evaporator, condenser and expansion valve. The model was then simulated on a MATLAB platform with a CoolProp installed packages via Python under two different simulation cases. In the first case, the mass fractions were varied for CuO,</span><span style="font-size:10.0pt;font-family:""> </span><span style="font-size:10.0pt;font-family:"">TiO<sub>2</sub> and Al<sub>2</sub>O<sub>3</sub> nanoparticles while their densities remained constant and a reversed condition was investigated for the second case. The results showed that both the refrigerating effect and the Coefficient Of Performance (COP) of the system increase as both the mass fraction and density of all the nanoparticles increases. It also shows that the compressor work decreases as both the mass fraction and density of all the nanoparticles were increased. On comparing the computational and numerical analysis results, the study established no significant difference in terms of COP and the use of nanoparticles were found to have improved the COP of the system. 展开更多
关键词 CoolProp Coefficient of performance Vapour Compression Refrigera-tion Mass Fraction
下载PDF
Experimental investigation of effect of refrigerant gases,compressor lubricant and operating conditions on performance of a heat pump
9
作者 AFSHARI Faraz SÖZEN Adnan +2 位作者 KHANLARI Ataollah TUNCER Azim Doğuş ALI Hafiz Muhammad 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第11期3556-3568,共13页
In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study des... In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element. 展开更多
关键词 heat pump efficiency coefficient of performance(COP) performance compressor oil charge amount
下载PDF
Refrigeration Performance Analysis and Its Applicability of a New Metal Hydride Couple in Auto Air-conditioning
10
作者 倪久建 陈江平 +3 位作者 陈芝久 覃峰 吕曼琪 杨柯 《Journal of Shanghai Jiaotong university(Science)》 EI 2005年第1期80-85,共6页
With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal ... With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal hydride selection model.The experimental results show that the refigeration cycle of the selected couple is good in the performance.The recovered waste heat and refrigeration power from exhaust gas of several kinds of automobile are calculated by waste-heat formula,coefficient R Q and COP.Refrigeration cycle of the new couple can satisfy the air-conditioning requirement of truck and car and is not enough in passenger car,according to the respective cooling load. 展开更多
关键词 metal hydried COUPLE refrigeration cycle coefficient of performance (COP)
下载PDF
Experimental Performance of TJR02 as an Alternative Refrigerant to R22 in a Small-Scale Cold Storage
11
作者 马洪亭 宋肖的 +1 位作者 杨国利 张于峰 《Transactions of Tianjin University》 EI CAS 2012年第5期330-334,共5页
A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be dir... A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be directly used in the system without modifying the original system or changing lubricant.By replacing R22 with TJR02,cooling rate gets faster and at least 20% of energy is saved.The actual detection in the standard test-bed verifies the experimental results and indicates that the adoption of TJR02 leads to greater efficiency and wider application.And the lower the refrigeratory temperature is,the more obvious the energy saving effects will be. 展开更多
关键词 alternative refrigerant TJR02 energy saving refrigeration capacity coefficient of performance
下载PDF
Study on the Evaluation Method of the Performances of Corporation
12
作者 Shaochuan Fu Chengxian Xu 《Chinese Business Review》 2004年第6期56-59,共4页
This paper studies the evaluation method of the performances of corporation that was set up by the Financial Ministry in 1999, and then analyzes the advantages and the problems of the method. Finally, this paper studi... This paper studies the evaluation method of the performances of corporation that was set up by the Financial Ministry in 1999, and then analyzes the advantages and the problems of the method. Finally, this paper studies the theoretical method of the evaluation of the performances of corporation. 展开更多
关键词 performance evaluation index system performance coefficient information system
下载PDF
Experimental Evaluation of the Heat Output/Input and Coefficient of Performance Characteristics of a Chemical Heat Pump in the Periodic Operation of CaCl<sub>2</sub>Hydration
13
作者 Atsuhiro Ichinose Kazuki Kuwata +2 位作者 Takehiro Esaki Takayuki Matsuda Noriyuki Kobayashi 《Journal of Materials Science and Chemical Engineering》 2020年第11期33-42,共10页
We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the... We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the practicality from the experimental results. The reactor module employed was an aluminum plate-tube heat exchanger with corrugated fins, and the CaCl<sub>2</sub> powder was in the form of a packed bed. Heat storage operation and heat dissipation operation are performed at the same time and supplied to the heat demand destination. At this time, an environmental heat source can be used during the heat radiation operation, and the heat output can release more heat than the heat input during heat storage. The heat discharging and charging characteristics of the reactor module were evaluated experimentally. The coefficient of performance (COP) was calculated for the heat upgrading cycle, and the heat output in the system was determined. A COP of 1.42 and output of 650 W/L, based on the heat exchanger volume, were obtained using a 600 s change time for the heat pump. 展开更多
关键词 Chemical Heat Pump CaCl2/H2O Hydration Reaction Heat Pump Cycle Coefficient of performance
下载PDF
Theoretical Study and Performance Analysis of an Adsorption Chiller
14
作者 Viorel Popa Liviu Costiuc Mihai Cuzic 《Journal of Energy and Power Engineering》 2012年第10期1570-1575,共6页
The thermodynamic cycle for an adsorption system is presented inp-T diagram. In order to investigate the performance of the adsorption system, a lumped parameter transient model of the chiller is developed, in order t... The thermodynamic cycle for an adsorption system is presented inp-T diagram. In order to investigate the performance of the adsorption system, a lumped parameter transient model of the chiller is developed, in order to predict the behaviors of the adsorption chiller system and find the influence of working conditions on its operation. For the working process of the main components of the system, including adsorber, condenser and evaporator, the coupled unsteady equations were set up for each stage. The model was then solved using stable numerical methods from EES (equation engineering solver), and the performance of the adsorber and condenser/evaporator of the system was analyzed. The condensation, evaporation and adsorber temperature values as well as the adsorption ratio and desorption ratio were obtained as function of operating time. Also, the coefficient of performance was analyzed in function of the heat source temperature and the cooling source temperature. 展开更多
关键词 Adsorbtion chiller coefficient of performance cooling systems numerical simulation.
下载PDF
Establishment of a Model for the Calculation of the COP of a Solar Adsorption Refrigerator
15
作者 Amadou Konfe Gilbert G. Nana +1 位作者 Salif Ouedraogo Sié Kam 《Smart Grid and Renewable Energy》 2023年第11期197-208,共12页
This paper deals with the evaluation of the Coefficient of Performance (COP) of solar adsorption refrigeration. In the literature, simulation models to predict the thermal behaviour and the coefficient of performance ... This paper deals with the evaluation of the Coefficient of Performance (COP) of solar adsorption refrigeration. In the literature, simulation models to predict the thermal behaviour and the coefficient of performance of these systems are uncommon. This is why we suggest a model to simulate the operation of the machine in a typical hot and dry climate of the city of Ouagadougou. The objective is to provide a model for calculating the COP from the measurement of the ambient temperature and the irradiation of a given site. Starting from mathematical modelling, a resolution and simulation were made with COMSOL software based on the Dubinin-Astakhov adsorption model, the heat transfer balance equations, and the Linear Driving Force (LDF) model to describe the thermal behaviour of the system. A one-week measurement sequence on the adsorption solar refrigerator at the Albert Schweitzer Ecological Centre (CEAS) validated the numerical results. The measurement shows that for the days with high sunshine, the temperature of the reaction medium reaches 110°C, and the pressure reaches 500 mbar. This leads to a production of cold that allows it to reach the temperature of -5°C at the evaporator. Under these conditions, the COP is worth 14%. These results are obtained both by numerical simulation using the COMSOL 5.1 software and after a measurement session on the solar refrigerator available to the CEAS. We obtained an experimental and theoretical coefficient of performance varying between 9% and 14% with a difference of between 0% and 3%. We conclude that our model is suitable to estimate the COP of any device based on its thermal properties, the ambient temperature and the irradiation of a given site. 展开更多
关键词 SOLAR REFRIGERATION ADSORPTION Coefficient of performance Modelling
下载PDF
Aqueous ammonia solution cooling absorption refrigeration driven by fishing boat diesel exhaust heat 被引量:5
16
作者 陈亚平 林陈敏 田莹 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期333-338,共6页
A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle fo... A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle for reclaiming some portion of absorption heat.As a consequence of raised temperature at the inlet,the strong solution partially boils at the outlet of the solution heat exchanger,and diminishes the thermal heat consumption of the heat source.The calculation results show that the coefficient of performance(COP)of this modified cycle is about 28.3% higher than that of the traditional cycle under typical conditions;while the required heat transfer area of the total heat exchangers of the cycle is somewhat less than that of the traditional one.The capacity of refrigeration with the new absorption cycle is more than doubled in contrast to the adsorption scheme with an identical configuration.It is sufficient to supply a fishing boat the chilling capacity for preservation of fishing products with the modified cycle chiller driven by its diesel engine exhaust. 展开更多
关键词 aqueous ammonia absorption refrigeration solution cooling absorption waste heat recovery heat and mass transfer coefficient of performance
下载PDF
回收余热的空气源热泵热水器的性能模拟及试验研究 被引量:4
17
作者 彭斌 王永强 《北京工业大学学报》 CAS CSCD 北大核心 2021年第12期1303-1310,1394,共9页
空气源热泵机组在较低的环境温度时,会出现结霜、制热量下降等问题.而余热空气源热泵系统以40℃低温余热作为低温热源,不仅避免了结霜、制热量下降等问题,而且回收了低温余热资源.通过构建空气源热泵系统的数学模型,揭示余热流量、温度... 空气源热泵机组在较低的环境温度时,会出现结霜、制热量下降等问题.而余热空气源热泵系统以40℃低温余热作为低温热源,不仅避免了结霜、制热量下降等问题,而且回收了低温余热资源.通过构建空气源热泵系统的数学模型,揭示余热流量、温度及冷水温度对系统性能的影响规律,并搭建试验平台验证数学模型的结果.结果显示,在热风温度为45℃、风量为4 500 m;/h时,系统的各项性能指标参数达到最佳值;随冷水温度的升高,系统性能系数(coefficient of performance, COP)的变化不明显;在冷水温度为10℃时,压比的偏差最大值为12.5%.回收余热的空气源热泵系统的性能模拟结果为低温余热的回收利用提供了一定的理论指导. 展开更多
关键词 空气源热泵 结霜 余热回收 数学模型 性能系数(coefficient of performance COP) 制热量
下载PDF
Experimental study on characteristics of transcritical heat pump water heater using refrigerant HFC125
18
作者 王方 连之伟 +1 位作者 范晓伟 王凤坤 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期182-186,共5页
To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car... To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average. 展开更多
关键词 HFC125 transcritical cycle heat pump water heater coefficient of performance(COP)
下载PDF
Parallel Operation Characteristics Analysis of Sewage Source Heat Pump Units in Winter 被引量:2
19
作者 庄兆意 张承虎 +1 位作者 王海燕 孙德兴 《Transactions of Tianjin University》 EI CAS 2010年第6期461-466,共6页
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running... Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi... 展开更多
关键词 sewage source heat pump unit coefficient of performance (COP) partial load parallel operation
下载PDF
Thermodynamic Comparison Analysis on CO_2 Transcritical Reverse Cycles with IHX or Expander 被引量:2
20
作者 管海清 马一太 +1 位作者 杨俊兰 李敏霞 《Transactions of Tianjin University》 EI CAS 2005年第2期110-114,共5页
To improve the coefficient of performance (COP) of CO2 transcritical reverse cycle and determine the most efficient cycle, comparison analysis on (single-and) two-stage CO2 transcritical cycles with internal heat ... To improve the coefficient of performance (COP) of CO2 transcritical reverse cycle and determine the most efficient cycle, comparison analysis on (single-and) two-stage CO2 transcritical cycles with internal heat exchanger (IHX) or expander is presented adopting the principle of thermodynamics. Results indicate that the COP of four cycles,namely single-stage compression with IHX (SI), single-stage compression with expander (SE), two-stage compression with IHX (TI) and two-stage compression with expander (TE), can be ranged as TE>SE>TI>SI. It presents that adopting an expander to recover expansion power is the primary method to improve the COP of CO2 transcritical reverse cycle if the efficiency of the expander is up to a certain value. Under supposed operating condition, where the outlet temperature of gas cooler is 35 ℃ and the evaporating temperature is 5 ℃, the COP of TE cycle is about 4200 higher than that of SI cycle when the expander efficiency is 0.6 and the degree of superheat of IHX is 15 ℃. Therefore TE cycle is the most recommendatory one and it is better to adopt TE in those high-cooling capacity systems because its technology cost will be higher. 展开更多
关键词 CO_2 transcritical reverse cycle internal heat exchanger EXPANDER coefficient of performance
下载PDF