This paper presents a simukaneous multi- objective optimization of a direct-drive permanent magnet synchronous generator and a three-blade horizontal-axis wind turbine for a large scale wind energy conversion system. ...This paper presents a simukaneous multi- objective optimization of a direct-drive permanent magnet synchronous generator and a three-blade horizontal-axis wind turbine for a large scale wind energy conversion system. Analytical models of the generator and the turbine are used along with the cost model for optimization. Three important characteristics of the system i.e.,the total cost of the generator and blades, the annual energy output and the total mass of generator and blades are chosen as objective functions for a multi-objective optimization. Genetic algorithm (GA) is then employed to optimize the value of eight design parameters including seven generator parameters and a turbine parameter resulting in a set of Pareto optimal solutions. Four optimal solutions are then selected by applying some practical restrictions on the Pareto front. One of these optimal designs is chosen for finite element verification. A circuit-fed coupled time stepping finite element method is then performed to evaluate the no-load and the full load performance analysis of the system including the generator, a rectifier and a resistive load. The results obtained by the finite element analysis (FEA) verify the accuracy of the analytical model and the proposed method.展开更多
随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,...随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,该文针对直流受端馈入站与近区风电场系统的振荡特性展开研究。首先,建立并验证系统的状态空间模型,基于该模型计算出系统特征值,确定LCC-HVDC与风电场共同参与的振荡主导模式并进行参与因子分析。进一步地,通过对比是否接入LCC-HVDC的主导模式,得到LCC-HVDC的接入会削弱系统阻尼的结论。最后,从系统额定容量、交流系统短路比、风电场并网线路长度等方面探究系统稳定性的影响因素,并分析系统的不同短路比、潮流比对风机网侧换流器(grid-side converter,GSC)外环控制和换流站定电流控制器性能的影响。展开更多
文摘This paper presents a simukaneous multi- objective optimization of a direct-drive permanent magnet synchronous generator and a three-blade horizontal-axis wind turbine for a large scale wind energy conversion system. Analytical models of the generator and the turbine are used along with the cost model for optimization. Three important characteristics of the system i.e.,the total cost of the generator and blades, the annual energy output and the total mass of generator and blades are chosen as objective functions for a multi-objective optimization. Genetic algorithm (GA) is then employed to optimize the value of eight design parameters including seven generator parameters and a turbine parameter resulting in a set of Pareto optimal solutions. Four optimal solutions are then selected by applying some practical restrictions on the Pareto front. One of these optimal designs is chosen for finite element verification. A circuit-fed coupled time stepping finite element method is then performed to evaluate the no-load and the full load performance analysis of the system including the generator, a rectifier and a resistive load. The results obtained by the finite element analysis (FEA) verify the accuracy of the analytical model and the proposed method.
文摘随着高压直流输电工程的不断投产,以及风电项目的增多,越来越多的风电场出现在电网换相换流器高压直流输电(line-commutated-converter based high voltage direct current,LCC-HVDC)受端换流站近区,两者构成的系统存在振荡风险。为此,该文针对直流受端馈入站与近区风电场系统的振荡特性展开研究。首先,建立并验证系统的状态空间模型,基于该模型计算出系统特征值,确定LCC-HVDC与风电场共同参与的振荡主导模式并进行参与因子分析。进一步地,通过对比是否接入LCC-HVDC的主导模式,得到LCC-HVDC的接入会削弱系统阻尼的结论。最后,从系统额定容量、交流系统短路比、风电场并网线路长度等方面探究系统稳定性的影响因素,并分析系统的不同短路比、潮流比对风机网侧换流器(grid-side converter,GSC)外环控制和换流站定电流控制器性能的影响。