The current study was designed to determine the safety, tolerability and pharmacokinetic parameters of recombinant human parathyroid hormone [rhPTH (1-84)] used for the treatment of osteoporosis. In the single-dose ...The current study was designed to determine the safety, tolerability and pharmacokinetic parameters of recombinant human parathyroid hormone [rhPTH (1-84)] used for the treatment of osteoporosis. In the single-dose format pharmacokinetic study, thirty-six healthy male volunteers received three dose levels of rhPTH (1-84) subcutaneously: 1, 2, and 4 μg/kg. The blood was timing drawn and the serum concentration of rhPTH (1-84) was determined by enzyme linked immunosorbent assay (ELISA). Serum concentration-time curves of PTH (1-84) exhibited a double-peak pattern, the first peak appearing about 10 to 30 min after administration and the second peak occurring about 1.5 to2 h after administration. Serum terminal half-time of PTH (1-84) was approximately 2 h. The parameters indicated the serum levels were directly proportional to the administered dose, with the mean Cmax and AUC0_24 ranging from approximately 543.47 to 1845 pg/mL and 2358.6 to 9232.12 pg.h.mL^-1 over the dose range. The drug was well tolerated, the clinical symptoms were generally mild and of short duration.展开更多
A highly sensitive ultra-high-performance liquid chromatographic-tandem mass spectro- metry (UPLC/MS/MS) method was developed for the quantification of the synthetic peptide drug of exenatide in monkey plasma. Sampl...A highly sensitive ultra-high-performance liquid chromatographic-tandem mass spectro- metry (UPLC/MS/MS) method was developed for the quantification of the synthetic peptide drug of exenatide in monkey plasma. Sample preparation was carried out by solid-phase extraction (SPE), and bivalirudin was used as the internal standard (IS). An excellent chromatographic separation was obtained on a reversed-phase C1s column with a gradient elution. Detection utilized a Qtrap 5500 system operated in the positive ion mode with multiple reaction monitoring (MRM). The proposed method was validated by assessing the specificity, linearity, intra- and inter-day precision and accuracy, recovery, and stability. The method resulted in a linear calibration range of 0.10-30 ng/mL, extracting with only 50 μL monkey plasma aliquots. The intra- and inter-day precisions (as relative standard deviation) were less than 7.5% and 9.6%, respectively. The methodcould be successfully utilized for the pharrnacokinetic study of exenatide in monkeys following a single subcutaneous injection of Byetta.展开更多
We described the first results of a quantitative ultra performance liquid chromatographytandem mass spectrometry method for a novel antimicrobial peptide (phylloseptin, PSN-1). Chromatographic separation was accompl...We described the first results of a quantitative ultra performance liquid chromatographytandem mass spectrometry method for a novel antimicrobial peptide (phylloseptin, PSN-1). Chromatographic separation was accomplished on a Waters bridged ethyl hybrid (BEH) C18 (50mm× 2.1 mm, 1.7 μm) column with acetonitrile-water (25:75, v/v) as isocratic mobile phase. Mass spectrometry detection was performed in the positive electrospray ionization mode and by monitoring of the transitions at m/z 679.6/120, 509.6/120 (PSN-1) and m/z 340.7/165 (Thymopentin, IS). Protein precipitation was investigated and the recovery was satisfactory (above 82%). The method was shown to be reproducible and reliable with intra-day precision below 5.3%, inter-day precision below 14.2%, and linear range from 0.02 to 2 lag/mL with r〉0.994. The method was successfully applied to a pharmacokinetic study of PSN-1 in rats after intravenous administration.展开更多
文摘The current study was designed to determine the safety, tolerability and pharmacokinetic parameters of recombinant human parathyroid hormone [rhPTH (1-84)] used for the treatment of osteoporosis. In the single-dose format pharmacokinetic study, thirty-six healthy male volunteers received three dose levels of rhPTH (1-84) subcutaneously: 1, 2, and 4 μg/kg. The blood was timing drawn and the serum concentration of rhPTH (1-84) was determined by enzyme linked immunosorbent assay (ELISA). Serum concentration-time curves of PTH (1-84) exhibited a double-peak pattern, the first peak appearing about 10 to 30 min after administration and the second peak occurring about 1.5 to2 h after administration. Serum terminal half-time of PTH (1-84) was approximately 2 h. The parameters indicated the serum levels were directly proportional to the administered dose, with the mean Cmax and AUC0_24 ranging from approximately 543.47 to 1845 pg/mL and 2358.6 to 9232.12 pg.h.mL^-1 over the dose range. The drug was well tolerated, the clinical symptoms were generally mild and of short duration.
基金supported by the National Basic Research Program of China (973 Program) (No. 2010CB735602 and No. 2012CB724003)
文摘A highly sensitive ultra-high-performance liquid chromatographic-tandem mass spectro- metry (UPLC/MS/MS) method was developed for the quantification of the synthetic peptide drug of exenatide in monkey plasma. Sample preparation was carried out by solid-phase extraction (SPE), and bivalirudin was used as the internal standard (IS). An excellent chromatographic separation was obtained on a reversed-phase C1s column with a gradient elution. Detection utilized a Qtrap 5500 system operated in the positive ion mode with multiple reaction monitoring (MRM). The proposed method was validated by assessing the specificity, linearity, intra- and inter-day precision and accuracy, recovery, and stability. The method resulted in a linear calibration range of 0.10-30 ng/mL, extracting with only 50 μL monkey plasma aliquots. The intra- and inter-day precisions (as relative standard deviation) were less than 7.5% and 9.6%, respectively. The methodcould be successfully utilized for the pharrnacokinetic study of exenatide in monkeys following a single subcutaneous injection of Byetta.
文摘We described the first results of a quantitative ultra performance liquid chromatographytandem mass spectrometry method for a novel antimicrobial peptide (phylloseptin, PSN-1). Chromatographic separation was accomplished on a Waters bridged ethyl hybrid (BEH) C18 (50mm× 2.1 mm, 1.7 μm) column with acetonitrile-water (25:75, v/v) as isocratic mobile phase. Mass spectrometry detection was performed in the positive electrospray ionization mode and by monitoring of the transitions at m/z 679.6/120, 509.6/120 (PSN-1) and m/z 340.7/165 (Thymopentin, IS). Protein precipitation was investigated and the recovery was satisfactory (above 82%). The method was shown to be reproducible and reliable with intra-day precision below 5.3%, inter-day precision below 14.2%, and linear range from 0.02 to 2 lag/mL with r〉0.994. The method was successfully applied to a pharmacokinetic study of PSN-1 in rats after intravenous administration.