It is a great challenge to find effective atomizing technology for reducing industrial pollution; the twin-fluid atomizing nozzle has drawn great attention in this field recently. Current studies on twin-fluid nozzles...It is a great challenge to find effective atomizing technology for reducing industrial pollution; the twin-fluid atomizing nozzle has drawn great attention in this field recently. Current studies on twin-fluid nozzles mainly focus on droplet breakup and single droplet characteristics. Research relating to the influences of structural parameters on the droplet diameter characteristics in the flow field is scarcely available. In this paper, the influence of a self-excited vibrating cavity structure on droplet diameter characteristics was investigated. Twin-fluid atomizing tests were performed by a self-built open atomizing test bench, which was based on a phase Doppler particle analyzer(PDPA). The atomizing flow field of the twin-fluid nozzle with a self-excited vibrating cavity and its absence were tested and analyzed. Then the atomizing flow field of the twin-fluid nozzle with different self-excited vibrating cavity structures was investigated.The experimental results show that the structural parameters of the self-excited vibrating cavity had a great effect on the breakup of large droplets. The Sauter mean diameter(SMD) increased with the increase of orifice diameter or orifice depth. Moreover, a smaller orifice diameter or orifice depth was beneficial to enhancing the turbulence around the outlet of nozzle and decreasing the SMD. The atomizing performance was better when the orifice diameter was2.0 mm or the orifice depth was 1.5 mm. Furthermore, the SMD increased first and then decreased with the increase of the distance between the nozzle outlet and self-excited vibrating cavity, and the SMD of more than half the atomizing flow field was under 35 μm when the distance was 5.0 mm. In addition, with the increase of axial and radial distance from the nozzle outlet, the SMD and arithmetic mean diameter(AMD) tend to increase. The research results provide some design parameters for the twin-fluid nozzle, and the experimental results could serve as a beneficial supplement to the twin-fluid nozzle study.展开更多
Spray atomization of liquid fuel plays an important role in droplet evaporation,combustible mixture formation and subsequent combustion process.Well-atomized liquid spray contributes to high fuel efficiency and low po...Spray atomization of liquid fuel plays an important role in droplet evaporation,combustible mixture formation and subsequent combustion process.Well-atomized liquid spray contributes to high fuel efficiency and low pollutant emissions.Gasoline direct injection(GDI)has been recognized as one of the most effective ways to improve fuel atomization.As a special direct injection method,the air-assisted direct injection utilizes high-speed flow of high-pressure air at the injector exit to assist liquid fuel injection and promote spray atomization at a low injection pressure.This injection method has excellent application potential and advantages for high performance and lightweight engines.In this study,the hollow cone spray emerging from an air-assisted injector was studied in a constant volume chamber with the ambient pressures ranging from 5 kPa to 300 kPa.External macro characteristics of spray were obtained using high speed backlit imaging.Phase Doppler particle analyzer(PDPA)was utilized to study the microcosmic spray characteristics.The results show that under the flash boiling condition,the spray will generate a strong flash boiling point which causes the cone shape spray to expand both inwards and outwards.The axisymmetric inward expansion would converge together and form a lathy aggregation area below the nozzle and the axisymmetric outward expansion greatly increases the spray width.The sauter mean diameter(SMD)of flash boiling condition can be reduced to 5μm compared to the level close to 10μm in the non-flash boiling condition.展开更多
基金Supported by National Natural Science Foundation of China(Grant No.51705445)Hebei Provincial Natural Science Foundation of China,(Grant No.E2016203324)Open Foundation of the State Key Laboratory of Fluid Power and Mechatronic Systems of China(Grant No.GZKF-201714)
文摘It is a great challenge to find effective atomizing technology for reducing industrial pollution; the twin-fluid atomizing nozzle has drawn great attention in this field recently. Current studies on twin-fluid nozzles mainly focus on droplet breakup and single droplet characteristics. Research relating to the influences of structural parameters on the droplet diameter characteristics in the flow field is scarcely available. In this paper, the influence of a self-excited vibrating cavity structure on droplet diameter characteristics was investigated. Twin-fluid atomizing tests were performed by a self-built open atomizing test bench, which was based on a phase Doppler particle analyzer(PDPA). The atomizing flow field of the twin-fluid nozzle with a self-excited vibrating cavity and its absence were tested and analyzed. Then the atomizing flow field of the twin-fluid nozzle with different self-excited vibrating cavity structures was investigated.The experimental results show that the structural parameters of the self-excited vibrating cavity had a great effect on the breakup of large droplets. The Sauter mean diameter(SMD) increased with the increase of orifice diameter or orifice depth. Moreover, a smaller orifice diameter or orifice depth was beneficial to enhancing the turbulence around the outlet of nozzle and decreasing the SMD. The atomizing performance was better when the orifice diameter was2.0 mm or the orifice depth was 1.5 mm. Furthermore, the SMD increased first and then decreased with the increase of the distance between the nozzle outlet and self-excited vibrating cavity, and the SMD of more than half the atomizing flow field was under 35 μm when the distance was 5.0 mm. In addition, with the increase of axial and radial distance from the nozzle outlet, the SMD and arithmetic mean diameter(AMD) tend to increase. The research results provide some design parameters for the twin-fluid nozzle, and the experimental results could serve as a beneficial supplement to the twin-fluid nozzle study.
基金Supported by Beijing Institute of Technology Research Fund Program for Young Scholars(2019CX04-031)Foundation Research Funds of Ministry of Industry and Information Technology(JCKY2019602D018)。
文摘Spray atomization of liquid fuel plays an important role in droplet evaporation,combustible mixture formation and subsequent combustion process.Well-atomized liquid spray contributes to high fuel efficiency and low pollutant emissions.Gasoline direct injection(GDI)has been recognized as one of the most effective ways to improve fuel atomization.As a special direct injection method,the air-assisted direct injection utilizes high-speed flow of high-pressure air at the injector exit to assist liquid fuel injection and promote spray atomization at a low injection pressure.This injection method has excellent application potential and advantages for high performance and lightweight engines.In this study,the hollow cone spray emerging from an air-assisted injector was studied in a constant volume chamber with the ambient pressures ranging from 5 kPa to 300 kPa.External macro characteristics of spray were obtained using high speed backlit imaging.Phase Doppler particle analyzer(PDPA)was utilized to study the microcosmic spray characteristics.The results show that under the flash boiling condition,the spray will generate a strong flash boiling point which causes the cone shape spray to expand both inwards and outwards.The axisymmetric inward expansion would converge together and form a lathy aggregation area below the nozzle and the axisymmetric outward expansion greatly increases the spray width.The sauter mean diameter(SMD)of flash boiling condition can be reduced to 5μm compared to the level close to 10μm in the non-flash boiling condition.