期刊文献+
共找到79篇文章
< 1 2 4 >
每页显示 20 50 100
Real-time and high-transmission middle-infrared optical imaging system based on a pixel-wise metasurface micro-polarization array
1
作者 马丽凤 杜杉 +6 位作者 常军 陈蔚霖 武楚晗 石鑫鑫 黄翼 钟乐 穆全全 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期304-309,共6页
Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following pro... Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following problems:poor real-time performance,low transmission and high requirements for fabrication and integration.Herein,we aim to improve the performance of real-time polarization imaging systems in the MIR waveband and solve the above-mentioned defects.Therefore,we propose a MIR polarization imaging system to achieve real-time polarization-modulated imaging with high transmission as well as improved performance based on a pixel-wise metasurface micro-polarization array(PMMPA).The PMMPA element comprises several linear polarization(LP)filters with different polarization angles.The optimization results demonstrate that the transmittance of the center field of view for the LP filters is up to 77%at a wavelength of4.0μm and an extinction ratio of 88 d B.In addition,a near-diffraction-limited real-time MIR imaging optical system is designed with a field of view of 5°and an F-number of 2.The simulation results show that an MIR polarization imaging system with excellent real-time performance and high transmission is achieved by using the optimized PMMPA element.Therefore,the method is compatible with the available optical system design technologies and provides a way to realize real-time polarization imaging in MIR wavebands. 展开更多
关键词 REAL-TIME middle infrared optical imaging system metasurface polarization array
下载PDF
Integral imaging-based tabletop light field 3D display with large viewing angle 被引量:1
2
作者 Yan Xing Xing-Yu Lin +9 位作者 Lin-Bo Zhang Yun-Peng Xia Han-Le Zhang Hong-Yu Cui Shuang Li Tong-Yu Wang Hui Ren Di Wang Huan Deng Qiong-Hua Wang 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第6期19-30,共12页
Light field 3D display technology is considered a revolutionary technology to address the critical visual fatigue issues in the existing 3D displays.Tabletop light field 3D display provides a brand-new display form th... Light field 3D display technology is considered a revolutionary technology to address the critical visual fatigue issues in the existing 3D displays.Tabletop light field 3D display provides a brand-new display form that satisfies multi-user shared viewing and collaborative works,and it is poised to become a potential alternative to the traditional wall and portable display forms.However,a large radial viewing angle and correct radial perspective and parallax are still out of reach for most current tabletop light field 3D displays due to the limited amount of spatial information.To address the viewing angle and perspective issues,a novel integral imaging-based tabletop light field 3D display with a simple flat-panel structure is proposed and developed by applying a compound lens array,two spliced 8K liquid crystal display panels,and a light shaping diffuser screen.The compound lens array is designed to be composed of multiple three-piece compound lens units by employing a reverse design scheme,which greatly extends the radial viewing angle in the case of a limited amount of spatial information and balances other important 3D display parameters.The proposed display has a radial viewing angle of 68.7°in a large display size of 43.5 inches,which is larger than the conventional tabletop light field 3D displays.The radial perspective and parallax are correct,and high-resolution 3D images can be reproduced in large radial viewing positions.We envision that this proposed display opens up possibility for redefining the display forms of consumer electronics. 展开更多
关键词 tabletop light field 3D display integral imaging compound lens array radial viewing angle
下载PDF
Ultrasound Imaging of Pipeline Crack Based on Composite Transducer Array 被引量:8
3
作者 Shou-Peng Song Ying-Jie Ni 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第5期25-34,共10页
Cracks, especially small cracks are di cult to be detected in oil and gas transportation pipelines buried underground or covered with layers of material by using the traditional ultrasonic inspection techniques. There... Cracks, especially small cracks are di cult to be detected in oil and gas transportation pipelines buried underground or covered with layers of material by using the traditional ultrasonic inspection techniques. Therefore, a new com?posite ultrasonic transducer array with three acoustic beam incidence modes is developed. The space model of the array is also established to obtain the defect reflection point location. And the crack ultrasound image is thus formed through a series of small cubical elements expanded around the point locations by using the projection of binariza?tion values extracted from the received ultrasonic echo signals. Laboratory experiments are performed on a pipeline sample with di erent types of cracks to verify the e ectiveness and performance of the proposed technique. From the image, the presence of small cracks can be clearly observed, in addition to the sizes and orientations of the cracks. The proposed technique can not only inspect common flaws, but also detect cracks with various orientations, which is helpful for defect evaluation in pipeline testing. 展开更多
关键词 Composite transducer array Ultrasound imaging CRACK NDT&E
下载PDF
Study of ultrasonic phased array inspection imaging technology for NDT 被引量:6
4
作者 单宝华 段忠东 欧进萍 《China Welding》 EI CAS 2006年第3期1-5,共5页
A research about the ultrasonic phased array imaging principle from A-scan signal to B-scan image for non-destructive testing (NDT) was conducted in this paper, the ultrasonic phased array inspection imaging system ... A research about the ultrasonic phased array imaging principle from A-scan signal to B-scan image for non-destructive testing (NDT) was conducted in this paper, the ultrasonic phased array inspection imaging system used in industrial field was developed and the experiment was performed on the steel testing block by the system with 64 elements, 5 MHz phased array transducer. Experimental results show that the flaws could be accurately detected and the flaws size could be estimated from the B-scan images, and the B-scan images could clearly show the location of the flaws, but the quality of B-scan images needs to be enhanced by digital signal processing and controlling dynamic focusing for improving the image resolution. 展开更多
关键词 non-destructive testing ultrasonic phased array INSPECTION imaging
下载PDF
ARRAY PULSED EDDY CURRENT IMAGING SYSTEM USED TO DETECT CORROSION 被引量:4
5
作者 YangBinfeng LuoFeilu CaoXiongheng XuXiaojie 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第2期196-198,共3页
A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC... A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC) imaging is proposed to detect corrosion. The testresults show that this system has the advantage of fast scanning speed, different imaging mode andquantitative detection, it has a broad application in the aviation nondestructive testing. 展开更多
关键词 array probe Pulsed eddy current Aircraft structure Corrosion imaging
下载PDF
Low-Strain Damage Imaging Detection Experiment for Model Pile Integrity Based on HHT
6
作者 Ziyang Jiang Ziping Wang +2 位作者 Kan Feng Yang Zhang Rahim Gorgin 《Structural Durability & Health Monitoring》 EI 2023年第6期557-569,共13页
With the advancement of computer and mathematical techniques,significant progress has been made in the 3D modeling of foundation piles.Existing methods include the 3D semi-analytical model for non-destructive low-stra... With the advancement of computer and mathematical techniques,significant progress has been made in the 3D modeling of foundation piles.Existing methods include the 3D semi-analytical model for non-destructive low-strain integrity assessment of large-diameter thin-walled pipe piles and the 3D soil-pile dynamic interaction model.However,these methods have complex analysis procedures and substantial limitations.This paper introduces an innovative and streamlined 3D imaging technique tailored for the detection of pile damage.The approach harnesses the power of an eight-channel ring array transducer to capture internal reflection signals within foundation piles.The acquired signals are subsequently processed using the Hilbert-Huang Transform(HHT),a robust analytical tool known for its effectiveness in handling non-stationary signals.Through the development of a sophisticated multi-channel ring array imaging algorithm,this technique empowers engineers and researchers to identify various pile defects,including their specific type,precise location,and obtain detailed 3D imaging representations.The findings of this research offer a valuable blend of theoretical insights and practical guidance,significantly advancing the state-of-the-art in the realm of concrete pile integrity inspection.By simplifying and enhancing the assessment process,this innovative approach not only addresses the complexities of existing methods but also contributes to the overall safety and reliability of concrete engineering structures. 展开更多
关键词 PILE integrity inspection annular array imaging HHT
下载PDF
An application of ultrasonic phased array imaging in electron beam welding inspection 被引量:2
7
作者 周琦 刘方军 +2 位作者 李志军 李旭东 齐铂金 《China Welding》 EI CAS 2002年第2期114-118,共5页
The basic principle and features of ultrasonic phased array imaging are discussed in this paper. Through the ultrasonic phased array technology, the electron beam welding defects and frozen keyholes characterization a... The basic principle and features of ultrasonic phased array imaging are discussed in this paper. Through the ultrasonic phased array technology, the electron beam welding defects and frozen keyholes characterization and imaging were realized. The ultrasonic phased array technology can detect kinds of defects in electron beam welding (EBW) quickly and easily. 展开更多
关键词 ultrasonic phased array imaging TRANSDUCER electron beam welding KEYHOLE
下载PDF
Precision integration of grating-based polarizers onto focal plane arrays of near-infrared photovoltaic detectors for enhanced contrast polarimetric imaging 被引量:5
8
作者 Bo Feng Yifang Chen +4 位作者 Duo Sun Zongyao Yang Bo Yang Xue Li Tao Li 《International Journal of Extreme Manufacturing》 EI 2021年第3期95-102,共8页
Polarimetric imaging enhances the ability to distinguish objects from a bright background by detecting their particular polarization status,which offers another degree of freedom in infrared remote sensing.However,to ... Polarimetric imaging enhances the ability to distinguish objects from a bright background by detecting their particular polarization status,which offers another degree of freedom in infrared remote sensing.However,to scale up by monolithically integrating grating-based polarizers onto a focal plane array(FPA)of infrared detectors,fundamental technical obstacles must be overcome,including reductions of the extinction ratio by the misalignment between the polarizer and the detector,grating line width fluctuations,the line edge roughness,etc.This paper reports the authors’latest achievements in overcoming those problems by solving key technical issues regarding the integration of large-scale polarizers onto the chips of FPAs with individual indium gallium arsenide/indium phosphide(In Ga As/In P)sensors as the basic building blocks.Polarimetric and photovoltaic chips with divisions of the focal plane of 540×4 pixels and 320×256 superpixels have been successfully manufactured.Polarimetric imaging with enhanced contrast has been demonstrated.The progress made in this work has opened up a broad avenue toward industrialization of high quality polarimetric imaging in infrared wavelengths. 展开更多
关键词 polarimetric imaging grating based polarizer INGAAS/INP focal plane array nanofabrication
下载PDF
Spatially modulated scene illumination for intensity-compensated two-dimensional array photon-counting LiDAR imaging 被引量:1
9
作者 谢佳衡 张子静 +3 位作者 黄明维 李家欢 贾凡 赵远 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第9期238-248,共11页
Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quant... Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quantum efficiency of the detectors in the 2D array deteriorate the imaging quality.Herein,we propose a photon-counting LiDAR system that uses a spatial light modulator to control the spatial intensity to compensate for both the non-uniform intensity profile of the illumination beam,and the variation in the quantum efficiency of the detectors in the 2D array.By using a 635 nm peak wavelength and 4 mW average power semiconductor laser,lab-based experiments at a 4.27 m stand-off distance are performed to verify the effectiveness of the proposed method.Compared with the unmodulated method,the standard deviation of the intensity image of the proposed method is reduced from 0.109 to 0.089 for a whiteboard target,with an average signal photon number of 0.006 per pixel. 展开更多
关键词 avalanche photodiode camera photon counting three-dimensional imaging array modulation
下载PDF
An active coronagraph using a liquid crystal array for exoplanet imaging:principle and testing 被引量:1
10
作者 Xi Zhang De-Qing Ren +1 位作者 Yong-Tian Zhu Jiang-Pei Dou 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2012年第5期591-600,共10页
High-contrast imaging coronagraphs, used for the detection of exoplanets, have always adopted passive coronagraph optical components. It is therefore impossible to actively optimize the coronagraphs to achieve their b... High-contrast imaging coronagraphs, used for the detection of exoplanets, have always adopted passive coronagraph optical components. It is therefore impossible to actively optimize the coronagraphs to achieve their best performance. To solve this problem, we propose a novel high-contrast imaging coronagraph which combines a liquid crystal array (LCA) for active pupil apodization and a deformable mirror (DM) for phase correction. The LCA we use is an amplitude-only spatial light mod- ulator. The LCA is well calibrated and compensates for its amplitude non-uniformity and nonlinear intensity responsivity. We measured the imaging contrasts of the coron- agraph system with the LCA only and without the DM deployed. Imaging contrasts of 10-4 and 10-5 can be reached at an inner working angular distance of 2.5 and 5A/D, respectively. A simulation shows that the phase errors on the coronagraph pupil limit the contrast performance. The contrast could be further improved if a DM is deployed to correct the phase errors induced by the LCA and coronagraph optics. 展开更多
关键词 instrumentation: coronagraph liquid crystal array - techniques high-contrast imaging exoplanet detection
下载PDF
An ultrasonic multi-wave focusing and imaging method for linear phased arrays
11
作者 戴宇翔 阎守国 张碧星 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第7期303-310,共8页
To overcome the inherent limits of traditional single wave imaging for nondestructive testing,the multi-wave focusing and imaging method is thoroughly studied.This method makes the compressional waves and shear waves ... To overcome the inherent limits of traditional single wave imaging for nondestructive testing,the multi-wave focusing and imaging method is thoroughly studied.This method makes the compressional waves and shear waves focused in both emission and reception processes,which strengthens the focusing energy and improves the signal-to-noise ratio of received signals.A numerical model is developed to study the characteristics of a multi-wave focusing field.It is shown that the element width approaching 0.8 wavelengths of shear waves can keep a balance between the radiation energy of two waves,which can achieve a desirable multi-wave focusing performance.And an experiment using different imaging methods for a linear phased array is performed.It can be concluded that due to the combination of the propagation and reflection characteristics of two waves,the multi-wave focusing and imaging method can significantly improve the imaging distinguishability of defects and expand the available sweeping range to a sector of-650 to 65°. 展开更多
关键词 multi-wave focusing ultrasonic imaging phased array non-destructive testing
下载PDF
Machine learning algorithm partially reconfigured on FPGA for an image edge detection system
12
作者 Gracieth Cavalcanti Batista Johnny Oberg +3 位作者 Osamu Saotome Haroldo F.de Campos Velho Elcio Hideiti Shiguemori Ingemar Soderquist 《Journal of Electronic Science and Technology》 EI CAS CSCD 2024年第2期48-68,共21页
Unmanned aerial vehicles(UAVs)have been widely used in military,medical,wireless communications,aerial surveillance,etc.One key topic involving UAVs is pose estimation in autonomous navigation.A standard procedure for... Unmanned aerial vehicles(UAVs)have been widely used in military,medical,wireless communications,aerial surveillance,etc.One key topic involving UAVs is pose estimation in autonomous navigation.A standard procedure for this process is to combine inertial navigation system sensor information with the global navigation satellite system(GNSS)signal.However,some factors can interfere with the GNSS signal,such as ionospheric scintillation,jamming,or spoofing.One alternative method to avoid using the GNSS signal is to apply an image processing approach by matching UAV images with georeferenced images.But a high effort is required for image edge extraction.Here a support vector regression(SVR)model is proposed to reduce this computational load and processing time.The dynamic partial reconfiguration(DPR)of part of the SVR datapath is implemented to accelerate the process,reduce the area,and analyze its granularity by increasing the grain size of the reconfigurable region.Results show that the implementation in hardware is 68 times faster than that in software.This architecture with DPR also facilitates the low power consumption of 4 mW,leading to a reduction of 57%than that without DPR.This is also the lowest power consumption in current machine learning hardware implementations.Besides,the circuitry area is 41 times smaller.SVR with Gaussian kernel shows a success rate of 99.18%and minimum square error of 0.0146 for testing with the planning trajectory.This system is useful for adaptive applications where the user/designer can modify/reconfigure the hardware layout during its application,thus contributing to lower power consumption,smaller hardware area,and shorter execution time. 展开更多
关键词 Dynamic partial reconfiguration(DPR) Field programmable gate array(FPGA)implementation image edge detection Support vector regression(SVR) Unmanned aerial vehicle(UAV) pose estimation
下载PDF
Design and Imaging Application of Room-Temperature Terahertz Detector with Micro-Bolometer Focal Plane Array
13
作者 Jun Wang Jun Gou +1 位作者 Zhi-Ming Wu Ya-Dong Jiang 《Journal of Electronic Science and Technology》 CAS CSCD 2016年第2期98-102,共5页
Room-temperature terahertz (THz) detectors indicate a great potential in the imaging application because of their real-time, compact bulk, and wide spectral band responding characteristics. THz detectors with differ... Room-temperature terahertz (THz) detectors indicate a great potential in the imaging application because of their real-time, compact bulk, and wide spectral band responding characteristics. THz detectors with different dimensions based on a micro-bridge structure have been designed and fabricated to get optimized micro-bolometer parameters from the test results of membrane deformation. A nanostructured titanium (Ti) thin film absorber is integrated in the micro-bridge structure of the VOx micro-bolometer by a combined process of magnetron sputtering and reactive ion etching (RIE), and its improvement of THz absorption is verified by an optical characteristics mesurement. Continuous-wave THz detection and imaging are demonstrated by using a 2.52 THz far infrared CO2 laser and a 320x240 vanadium oxide micro-bolometer focal plane array with an optimized cell structure. With this detecting system, THz imaging of metal concealed in a wiping cloth and an envelope is demonstrated, respectively. 展开更多
关键词 Index Terms---Focal plane array micro-bolometer structure real-time imaging room temperatureterahertz detector
下载PDF
Simultaneous Measurement of Neural Activities of Acute Mouse Hippocampal Slices Using Multi-Electrode Array System and Laser Confocal Calcium Imaging
14
作者 Yuuta Hamasaki Natsumi Haba +2 位作者 Naoki Iwata Yoshiki Uno Minoru Saito 《Journal of Behavioral and Brain Science》 2017年第2期68-78,共11页
Recently, non-invasive, real-time and multi-point measurement of neural activities has become possible by using a multi-electrode array (MEA). Another method for multi-point measurement is the fluorescent imaging tech... Recently, non-invasive, real-time and multi-point measurement of neural activities has become possible by using a multi-electrode array (MEA). Another method for multi-point measurement is the fluorescent imaging technique using voltage indicator dyes or calcium indicator dyes. Especially, calcium imaging using fluorescent calcium indicator dyes is often more useful, because they exhibit larger changes in the fluorescence intensity than voltage indicator dyes and their fluorescence changes can be detect easily. Additionally, calcium signals play key roles in the brain function, such as the long-term potentiation (LTP) in the hippocampus, and calcium imaging can be a powerful tool to elucidate the brain function. In this study, we constructed a measurement apparatus combining the MEA system and laser confocal calcium imaging and simultaneously measured electric signals and calcium signals in acute mouse hippocampal slices. The obtained results showed the availability of the present method. 展开更多
关键词 MULTI-ELECTRODE array LASER CONFOCAL Calcium imaging Hippocampus ACUTE SLICE Long-Term POTENTIATION
下载PDF
Sparse three-dimensional imaging for forward-looking array SAR using spatial continuity
15
作者 LIU Xiangyang ZHANG Bingpeng +1 位作者 CAO Wei XIE Wenjia 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2021年第2期417-424,共8页
For forward-looking array synthetic aperture radar(FASAR),the scattering intensity of ground scatterers fluctuates greatly since there are kinds of vegetations and topography on the surface of the ground,and thus the ... For forward-looking array synthetic aperture radar(FASAR),the scattering intensity of ground scatterers fluctuates greatly since there are kinds of vegetations and topography on the surface of the ground,and thus the signal-to-noise ratio(SNR)of its echo signals corresponding to different vegetations and topography also varies obviously.Owing to the reason known to all,the performance of the sparse reconstruction of compressed sensing(CS)becomes worse in the case of lower SNR,and the quality of the sparse three-dimensional imaging for FASAR would be affected significantly in the practical application.In this paper,the spatial continuity of the ground scatterers is introduced to the sparse recovery algorithm of CS in the threedimensional imaging for FASAR,in which the weighted least square method of the cubic interpolation is used to filter out the bad and isolated scatterer.The simulation results show that the proposed method can realize the sparse three-dimensional imaging of FASAR more effectively in the case of low SNR. 展开更多
关键词 forward-looking array synthetic aperture radar(FASAR) sparse three-dimensional imaging compressed sensing(CS) spatial continuity
下载PDF
Holographic Microwave Imaging Array for Brain Stroke Detection
16
作者 Lulu Wang A. M. Al-Jumaily Ray Simpkin 《Journal of Signal and Information Processing》 2013年第3期96-101,共6页
This paper proposes a new holographic microwave imaging array (HMIA) technique for brain stroke detection. This approach is based on holographic microwave and aperture synthesis imaging techniques. The system is desig... This paper proposes a new holographic microwave imaging array (HMIA) technique for brain stroke detection. This approach is based on holographic microwave and aperture synthesis imaging techniques. The system is designed for operation at a single frequency of 2.5 GHz. A realistic three dimensional (3D) head model that contains skin, fat, skull, cerebrospinal fluid (CSF), grey matter, white matter and ischemic or hemorrhagic stroke area is developed using MATLAB to demonstrate the proposed HMIA imaging algorithm.A matching solution medium is used between the antennas and the head model. The study is conducted using HMIA computer simulations and 3D head model with-stroke.The simulation results showed that small stroke area (5 mmin diameter) could be successfully detected with the HMIA approach. 展开更多
关键词 MICROWAVE imaging HOLOGRAPHIC MICROWAVE imaging array Aperture Synthesis imaging BRAIN imaging BRAIN STROKE
下载PDF
Circular Ribbon Antenna Array Design For Imaging Application
17
作者 Rajinikanth Yella Krishna Pande Ke Horng Chen 《Journal of Electronic & Information Systems》 2021年第1期36-39,共4页
Our goal is to develop THz module on chip to visualize bone grinding at the early stage so that arthritis can be visualized and treated early.A critical component of such module is antenna.A compact 4 by 4 beamforming... Our goal is to develop THz module on chip to visualize bone grinding at the early stage so that arthritis can be visualized and treated early.A critical component of such module is antenna.A compact 4 by 4 beamforming antenna array for biomedical application is presented in this paper.We are proposing a novel antenna which is in the form of a circular ribbon shape with a gold patch.Gold material for the patch is used to enhance its conductivity and to cut down backward radiation.Differential port pin used to increase the bandwidth.Au-posts are finally used for output connection.The proposed antenna operates over the frequency band from 201 GHz to more than 228 GHz.Directivity and gain of the proposed antenna are 13 dB and 7 dB respectively.This makes it applicable for imaging systems because of the frequency band for biomedical imaging.Index Terms-Beamforming antenna,antenna array,Advanced design system(ADS),Biomedical imaging. 展开更多
关键词 Beamforming antenna Antenna array Advanced design system(ADS) Biomedical imaging
下载PDF
Efficient single‑pixel imaging based on a compact fiber laser array and untrained neural network
18
作者 Wenchang Lai Guozhong Lei +5 位作者 Qi Meng Yan Wang Yanxing Ma Hao Liu Wenda Cui Kai Han 《Frontiers of Optoelectronics》 EI CSCD 2024年第1期85-93,共9页
This paper presents an efficient scheme for single-pixel imaging(SPI)utilizing a phase-controlled fiber laser array and an untrained deep neural network.The fiber lasers are arranged in a compact hexagonal structure a... This paper presents an efficient scheme for single-pixel imaging(SPI)utilizing a phase-controlled fiber laser array and an untrained deep neural network.The fiber lasers are arranged in a compact hexagonal structure and coherently combined to generate illuminating light fields.Through the utilization of high-speed electro-optic modulators in each individual fiber laser module,the randomly modulated fiber laser array enables rapid speckle projection onto the object of interest.Furthermore,the untrained deep neural network is incorporated into the image reconstructing process to enhance the quality of the reconstructed images.Through simulations and experiments,we validate the feasibility of the proposed method and successfully achieve high-quality SPI utilizing the coherent fiber laser array at a sampling ratio of 1.6%.Given its potential for high emitting power and rapid modulation,the SPI scheme based on the fiber laser array holds promise for broad applications in remote sensing and other applicable fields. 展开更多
关键词 Single-pixel imaging Fiber laser array Deep learning Remote sensing
原文传递
Simplified Matrix Focusing Imaging Algorithm for Ultrasonic Nondestructive Testing 被引量:2
19
作者 Xinyu Zhao Zemin Ma Jiaying Zhang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2022年第2期201-209,共9页
Full matrix focusing method of ultrasonic phased array has been proved with advantages of good signal-to-noise ratio and imaging resolution in the field of Ultrasonic NDT.However,it is still suffering from the time-co... Full matrix focusing method of ultrasonic phased array has been proved with advantages of good signal-to-noise ratio and imaging resolution in the field of Ultrasonic NDT.However,it is still suffering from the time-consuming data acquisition and processing.In order to solve the problem,two simplified matrix focusing methods are provided in the paper.One provided method is a triangular matrix focusing algorithm based on the principle of reciprocity for the multi-channel ultrasonic system.The other provided method is a trapezoidal matrix focusing algorithm based on the energy weight of the different channel to the focusing area.Time of data acquisition and computational is decreased with the provided simplified matrix focusing methods.In order to prove the validity of two provided algorithms,both side-drilled holes and oblique cracks are used for imaging experiments.The experimental results show that the imaging quality of the triangular matrix focusing algorithm is basically consistent to that of the full matrix focusing method.And imaging quality of the trapezoidal matrix focusing algorithm is slightly reduced with the amount of multi-channel data decreasing.Both data acquisition and computational efficiency using the triangular matrix focusing algorithm and the trapezoidal matrix focusing algorithm have been improved significantly compared with original full matrix focusing method. 展开更多
关键词 Ultrasonic NDT Phased array Full matrix focusing imaging algorithms
下载PDF
Ultrasound Imaging of Spinal Vertebrae to Study Scoliosis 被引量:2
20
作者 Wei Chen Lawrence H. Le Edmond H.M. Lou 《Open Journal of Acoustics》 2012年第3期95-103,共9页
Scoliosis is a musculoskeletal disorder manifested as a three-dimensional spinal deformity. It affects 2% - 3% of the adolescent population. The conventional method to diagnose scoliosis is to measure the Cobb angle f... Scoliosis is a musculoskeletal disorder manifested as a three-dimensional spinal deformity. It affects 2% - 3% of the adolescent population. The conventional method to diagnose scoliosis is to measure the Cobb angle from posteroante-rior radiograph. Since radiation exposure is not desirable for patients, other non-ionizing methods have been explored. Among all the non-ionization methods, ultrasound (US) is a potential cost-effective method. However, our understand-ing of US interaction with the vertebrae or the spine is limited. The purpose of this study was to demonstrate the ability of US to identify bony landmarks for measuring spinal deformity. This study used a phased array US system with a 5 MHz transducer and a position encoder. In-vitro experiment on a cadaver vertebra and a pilot clinical study were carried out. The in-vitro experimental results showed that the lamina and spinous process were strong reflectors from the single vertebra. Less than 4% of error occurred on the dimension measurements. The pilot study was performed on a healthy subject and a scoliotic patient. The results indicated the lamina and spinous process could be identified and the curvature of the spine could be estimated using the reflectors. The difference of the curvature angle of the spine measured from the radiograph and the US images was 2?. These results have illustrated that US is a promising tool to measure curvature of spinal deformity and study scoliosis. 展开更多
关键词 Ultrasound COBB ANGLE Phased array SCOLIOSIS SPINAL DEFORMITY Ultrasonic imaging
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部