期刊文献+
共找到2,878篇文章
< 1 2 144 >
每页显示 20 50 100
Review of Three-phase Soft Switching Inverters and Challenges for Motor Drives
1
作者 Haifeng Lu Qiao Wang +1 位作者 Jianyun Chai Yongdong Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期177-190,共14页
For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging ... For electric vehicles (EVs),it is necessary to improve endurance mileage by improving the efficiency.There exists a trend towards increasing the system voltage and switching frequency,contributing to improve charging speed and power density.However,this trend poses significant challenges for high-voltage and high-frequency motor controllers,which are plagued by increased switching losses and pronounced switching oscillations as consequences of hard switching.The deployment of soft switching technology presents a viable solution to mitigate these issues.This paper reviews the applications of soft switching technologies for three-phase inverters and classifies them based on distinct characteristics.For each type of inverter,the advantages and disadvantages are evaluated.Then,the paper introduces the research progress and control methods of soft switching inverters (SSIs).Moreover,it presents a comparative analysis among the conventional hard switching inverters (HSIs),an active clamping resonant DC link inverter (ACRDCLI) and an auxiliary resonant commuted pole inverter (ARCPI).Finally,the problems and prospects of soft switching technology applied to motor controllers for EVs are put forward. 展开更多
关键词 soft switching inverters Zero-voltage switching Electric vehicles Motor drives
下载PDF
SOFT SWITCHED SYNCHRONOUS RECTIFIER WITH PHASE-SHIFTED FULL BRIDGE CONVERTER AND ITS SMALL-SIGNAL ANALYSIS
2
作者 潘三博 潘俊民 万健如 《Transactions of Tianjin University》 EI CAS 2006年第1期6-12,共7页
By using the output inductors and body capacitances without adding any component compared with hard switching synchronous rectifier,the topology of a soft switched synchronous rectifier with phase-shifted full bridge ... By using the output inductors and body capacitances without adding any component compared with hard switching synchronous rectifier,the topology of a soft switched synchronous rectifier with phase-shifted full bridge zero voltage switching DC/DC converter is proposed. The converter efficiency is maximized due to soft switching of the full bridge MOSFETs and the synchronous MOSFETs, and also the low conduction loss of synchronous MOSFET. The operation principles of the circuit are analyzed in detail and the small-signal model is derived, also the converter dynamic characteristics are analyzed. Frequency responses of transfer functions under different values of transformer primary leakage inductance are discussed. The experimental results were obtained from a 400 V input and 100 A/12 V output DC/DC converter operating at 100 kHz. The results show that the converter efficiency is 2% higher in rated power than traditional diode rectifier. 展开更多
关键词 phase-shifted full bridge zero voltage switch synchronous rectifier DC/DC small signal
下载PDF
Soft-switching Grid-connected PV Inverter With Interleaved Flyback Topology 被引量:15
3
作者 古俊银 吴红飞 +1 位作者 陈国呈 邢岩 《中国电机工程学报》 EI CSCD 北大核心 2011年第36期I0005-I0005,共1页
提出一种应用于单个光伏组件的软开关交错反激并网逆变器拓扑及其软开关控制策略。针对反激变压器漏感问题,提出漏感能量吸收回馈电路,实现了漏感能量吸收再利用,并实现了开关管漏源电压的钳位,提高了变换效率同时降低了开关管关断... 提出一种应用于单个光伏组件的软开关交错反激并网逆变器拓扑及其软开关控制策略。针对反激变压器漏感问题,提出漏感能量吸收回馈电路,实现了漏感能量吸收再利用,并实现了开关管漏源电压的钳位,提高了变换效率同时降低了开关管关断电压尖峰;提出基于数字处理器的反激变换器变开关频率谐振软开关控制策略,实现了开关管的零电压开通,同时改善了逆变器的电磁兼容特性;提出的交错并联反激逆变器有助于减小变压器和滤波器的体积,提高功率密度。详细分析变换器的工作原理,分析变开关频率谐振软开关控制方式的原理和实现条件,最后进行实验验证。 展开更多
关键词 拓扑结构 反激式 逆变器 软交换网 光伏 交错 软交换技术 低成本
下载PDF
Rugged Resonant Pole and Its Applications in Soft-Switching Converter
4
作者 肖岚 严仰光 《Journal of Southeast University(English Edition)》 EI CAS 2002年第3期225-232,共8页
The soft switching operation principle and operation performance of rugged resonant pole (RRP) is given. The applications of RRP in soft switching DC DC converter and soft switching inverter are discussed in detail. R... The soft switching operation principle and operation performance of rugged resonant pole (RRP) is given. The applications of RRP in soft switching DC DC converter and soft switching inverter are discussed in detail. RRP can constitute buck boost soft switching DC DC converter and isolated soft switching DC DC converter with the automatic limitation performance of output power. Partial series resonant DC DC converter with RRP can realize the zero voltage/zero current switching of power devices. RR... 展开更多
关键词 rugged resonant pole soft switching DC DC converter INVERTER
下载PDF
Research on Rugged Resonant DC Link Soft-Switching Static Inverter
5
作者 肖岚 胡敏强 《Journal of Southeast University(English Edition)》 EI CAS 2000年第1期34-40,共7页
A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse c... A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment. 展开更多
关键词 static inverter RESONANT soft switching discrete pulse control
下载PDF
ANALYSIS OF A NEW SOFT SWITCHING PWM INVERTER
6
作者 丁洛 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1995年第2期172-179,共8页
Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A ... Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A detailed analysis of the soft switching process in the rugged resonant dc link and the realization of pulse width modulation (PWM) control strategy in the inverter bridge are presented in the paper. The operation modes, the input and output features and the interface between the rugged resonant dc link and the inverter bridge are also discussed. The relationship between the circuit features and the parameters is deduced, which provides a theoretical base for the circuit design. The analysis results show that the rugged resonant dc link can be regulated by open-loop control and the control of the rugged resonant dc link is independent of that of the inverter bridge, which makes the inverter control easy and realizable.The circuit of the inverter is simulated with a standard circuit simulation program PSPICE. The simulation results are corresponding to the predicted ones of the circuit analysis. 展开更多
关键词 INVERTERS pulse width modulation resonant circuits soft switching cascade converter
下载PDF
基于Soft Switch的IN/Internet互通研究
7
作者 王田 曹长修 汪纪锋 《重庆邮电学院学报(自然科学版)》 2001年第3期33-37,共5页
在分析IN与Internet互通接口的基础上.基于 Soft Switch的思想提出了用 Virtual Switch实现IN/Internet互通的方案;时Virtual Switch的逻辑实体、信令功能、体系结构和业... 在分析IN与Internet互通接口的基础上.基于 Soft Switch的思想提出了用 Virtual Switch实现IN/Internet互通的方案;时Virtual Switch的逻辑实体、信令功能、体系结构和业务特点等问题进行了深入分析.并利用Virtual Switch实现了Virtual SSP和Virtual SCP. 展开更多
关键词 智能网 因特网 软交换 网络互通
下载PDF
下一代网络及其核心技术Soft Switch 被引量:3
8
作者 王蓓 《微机发展》 2005年第8期8-9,12,共3页
下一代网络(NGN)是目前通信领域发展的热点,业界主要指采用软交换技术而构建的新型网络。文中简要地阐述了NGN的基本概念及其在通信领域中的各方面研究。详细地分析了其核心技术———软交换在网络服务中所能提供的技术支持及其在发展... 下一代网络(NGN)是目前通信领域发展的热点,业界主要指采用软交换技术而构建的新型网络。文中简要地阐述了NGN的基本概念及其在通信领域中的各方面研究。详细地分析了其核心技术———软交换在网络服务中所能提供的技术支持及其在发展中的优势与不足。这对于未来网络发展有一定的指导作用。 展开更多
关键词 下一代网络 软交换 网络服务
下载PDF
COMPUTERIZED SIMULATION AND EXPERIMENTAL RESEARCH ON SOFT-SWITCHING ARC WELDING INVERTER POWER SOURCE 被引量:24
9
作者 S. J. Chen S. Y. Yin L. Feng and L. Y. Li( 1) School of Materials Science and Engineering, Beijing Polytechnic University, Beijing 100022, China 2)National Key Laboratory of Advanced Welding Production Technology, HIT, Harbin 150001, China) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2000年第1期128-132,共5页
Based on the existing component models in the Pspice software package, a combined model for Insulat- ed the Bipolar Transistor (IGBT) is established, in which a non - linear is introduced to represent the parasitic ... Based on the existing component models in the Pspice software package, a combined model for Insulat- ed the Bipolar Transistor (IGBT) is established, in which a non - linear is introduced to represent the parasitic capacitance. Using this model, computerized simulation is conducted for the FB - ZVZCS - PWM soft - ewitching converter,the switching and energy-transferring characteristics of the components are analyzed.The simulation results are testified by experiments.It is proved that by abopting appropriate models,computerized simulation becomes an effective tool for investigation of arc welding inverter power source. 展开更多
关键词 arc welding inverter computerized simulation.IGBT soft switching
下载PDF
COMPOSITE SOFT SWITCHING CONFIGURATION FOR INVERTERS USING BRIDGE LEG MODULES 被引量:7
10
作者 He Xiangning Yang Yuwen (Dept of Electrical Eng., Zhejiang University, Hangzhou 310027)Kuang Sheng(Department of Engineering, University of Cambridge, Cambridge, U.K.)Barry W. Williams Stephen J. Finney(Dept. of Computing & Electrical Eng., Heriot-Watt University, Edinburgh EH14 4AS, U.K.) 《Journal of Electronics(China)》 2001年第1期61-69,共9页
The use of either lossless snubbers or resonant zero voltage switching (ZVS) and zero current switching (ZCS) techniques can increase efficiency and reduce electromagnetic inter ference (EMI) and noise of industrial p... The use of either lossless snubbers or resonant zero voltage switching (ZVS) and zero current switching (ZCS) techniques can increase efficiency and reduce electromagnetic inter ference (EMI) and noise of industrial power equipment at high switching frequencies. This paper presents an adaptive composite soft switching configuration which combines snubber functions and resonant ZCS circuits for switches in inverters using power bridge leg modules. Simulation and experimental results are included. 展开更多
关键词 INVERTER Snubber soft switching IGBT MODULES
下载PDF
Simulation on Soft-Switching PWM Converter with High Power Factor 被引量:1
11
作者 CHENGuo-cheng KatsunoriTaniguchi 《Journal of Shanghai University(English Edition)》 CAS 2001年第2期123-129,共7页
A new PWM converter based on soft switching is introduced. The converter uses a minimum number of devices, and requires less switching operations than conventional techniques. Switching is realized solely in a ZVS (z... A new PWM converter based on soft switching is introduced. The converter uses a minimum number of devices, and requires less switching operations than conventional techniques. Switching is realized solely in a ZVS (zero voltage switching) mode, therefore the loss is reduced and EMI (electromagnetic interference) is suppressed. The paper analyzes the operation of ZVS, and discusses the methods for maintaining a unit power factor and constant DC voltage. Changing the modulation index M and the phase angle θ keeps the input current in phase with the voltage. It also keeps the current sinusoidal, and ensures a constant output voltage. 展开更多
关键词 soft switching CONVERTER ZVS(zero voltage switching) PWM EMI(electromagnetic interference)
下载PDF
SIMULATION AND EXPERIMENTATION OF THE ARC WELDING INVERTER USING THE SOFT SWITCHING TECHNIQUE 被引量:1
12
作者 ChenShujun WangJun HuangPengfei 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2004年第1期82-84,共3页
The FB-ZVZCS-PWM converter is realized by the way of subjoiningblock-capacitor into the FB-ZVS-PWM converter. At the freewheeling interval, the primary current isattenuated fast to zero and maintained. And then, power... The FB-ZVZCS-PWM converter is realized by the way of subjoiningblock-capacitor into the FB-ZVS-PWM converter. At the freewheeling interval, the primary current isattenuated fast to zero and maintained. And then, power device of the static leg becomes azero-current-switch (ZCS), power device of the shifted leg becomes a zero-voltage-switch(ZVS). Thus,on one hand IGBT (Insulated gate bipolar transistor) with tail current can be easily used infull-bridge soft-switching converter; on the other hand additional circuiting energy is greatlyreduced. At the same time, less duty cycle loss, lower secondary parasitic resonance, widersoft-switching load range can be achieved. Based on the existing component models in the Pspicesoftware package, a combined model of IGBT is established, in which a non-linear capacitor isintroduced to replace the parasitic capacitor. Using this model, computerized simulation isconducted for the FB-ZVZCS-PWM soft-switching converter, the switching and energy-transferringcharacteristics of the power device are analyzed. Finally, based on the achievement above, a 10 kWarc welding inverter with FB-ZVZCS-PWM converter is developed. The simulation results are testifiedby experiments. It is proved that by adopting appropriate models, computerized simulation is aneffective and useful tool for the development of the arc welding inverter. 展开更多
关键词 Arc welding inverter soft switching Zero-voltage-switching(ZVS) Zero-currentswitc-hing(ZCS)
下载PDF
Implementation strategy for soft switching PFC with low output voltage 被引量:1
13
作者 贲洪奇 原树斌 王大庆 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2006年第6期644-648,共5页
This paper proposes a novel implementation strategy for soft switching PFC whose circuit is simple and can achieve low voltage output directly. The main circuit adopts current mode full-bridge converter and all the po... This paper proposes a novel implementation strategy for soft switching PFC whose circuit is simple and can achieve low voltage output directly. The main circuit adopts current mode full-bridge converter and all the power switches can realize ZCS or ZVS in the way of phase-shlfted control, using the leakage inductance of the transformer, the junction capacitor of the switches and the stored energy of the output capacitor. The problems such as the function of phase-shlfted link in control circuit, the implementation conditions of soft switching and bias restrained are analyzed. The adoption of constant frequency PWM control makes the design of the input and output filter link and the high frequency transformer simple. The transformation ratio regulation so as to achieve low voltage output and electrical insulation can be realized by using high frequency transformer. 展开更多
关键词 power factor correction soft switching FULL-BRIDGE low voltage
下载PDF
Effects of Direct Switching Dual Bronchodilators between Dry Powder and Soft Mist Inhalers in COPD Patients 被引量:1
14
作者 Taisuke Akamatsu Toshihiro Shirai +11 位作者 Hiromasa Nakayasu Kanami Tamura Toshihiro Masuda Shingo Takahashi Yuko Tanaka Hirofumi Watanabe Yutaro Kishimoto Kyohei Oishi Mika Saigusa Akito Yamamoto Satoru Morita Kazuhiro Asada 《Open Journal of Respiratory Diseases》 2020年第1期11-19,共9页
Objective: Dual bronchodilation with long-acting muscarinic antagonist and long-acting β2-agonist combinations are available worldwide in COPD patients. However, the choice of agents remains under debate. We hypothes... Objective: Dual bronchodilation with long-acting muscarinic antagonist and long-acting β2-agonist combinations are available worldwide in COPD patients. However, the choice of agents remains under debate. We hypothesized that switching devices between dry powder and soft mist inhalers without a wash-out period to mimic clinical practice would improve clinical symptoms and lung function. The aim of this study was to examine the effects of switching between once-daily glycopyrronium/indacaterol (GLY/IND) or umeclidinium/vilanterol (UMEC/VI), dry powder inhalers, and tiotropium/olodaterol (TIO/OLO), a soft mist inhaler, in COPD patients. Methods: This was a prospective, open-label, 8-week, observational study with follow-up. Subjects included 57 COPD patients, who attended outpatient clinics at Shizuoka General Hospital for routine check-ups between February and December 2015, receiving GLY/IND (50/110 μg) or UMEC/VI (62.5/25 μg). After an 8-week run-in period, medications were switched to TIO/OLO (5/5 μg). Study outcomes included patient’s global rating (PGR), modified MRC (mMRC), COPD assessment test (CAT), and spirometric and forced oscillatory parameters after 8 weeks. PGR used in this study was a 7-point scale ranging from 1 to 7, with 4 in the middle. Patients who consented to switch from TIO/OLO to GLY/IND or UMEC/VI were followed-up thereafter. Results: In total, 53 patients completed the study (mean age, 75 years;48 males and 5 females;GOLD 1/2/3/4 = 19/27/6/1;mMRC 0/1/2/3/4 = 14/22/12/4/1;UMEC/VI 26, GLY/IND 27). PGR, mMRC, and CAT improved in 20 (38%), 9 (17%), and 15 patients (28%), respectively. Respiratory system resistance at 5 Hz (R5), 20 Hz (R20), and the difference between R5 and R20 (R5 - R20) significantly improved. In a follow-up of 16 patients after switching from TIO/OLO to UMEC/VI (9) or GLY/IND (7), PGR, mMRC, and CAT improved in 5 (31%), 3 (12%), and 4 patients (25%), respectively, and R20 significantly improved (p = 0.011). Conclusions: Switching dual bronchodilators between dry powder and soft mist inhalers improves symptoms and airway narrowing in some COPD patients. 展开更多
关键词 Device Dry Powder INHALER DUAL Bronchodilator soft MIST INHALER switchING
下载PDF
Computer Aided Analysis ofAC Drive System with Soft Switching Inverter
15
作者 王聪 张晓晴 《International Journal of Mining Science and Technology》 SCIE EI 1997年第2期95-100,共6页
The design of a general simulation package for AC drive system with soft switching inverter is discussed in this paper. This package is based on the secondary developing of the nonlinear control system simulation lang... The design of a general simulation package for AC drive system with soft switching inverter is discussed in this paper. This package is based on the secondary developing of the nonlinear control system simulation language SIMNON. Being constructed with modularization programming, the package can be used for general purposes conveuieutly and has strong graphic functions. The design principle for this simulation package is discussed in datail in this peper; and an application example (DSC controlled AC drive system with RDCLI) as well as its simulation results are given. 展开更多
关键词 COMPUTER simulation soft switchING techuique INVERTER AC DRIVES
下载PDF
Reducing the minimum output power of soft-switching inverter arc welding power supplies 被引量:1
16
作者 傅强 薛松柏 《China Welding》 EI CAS 2010年第3期45-49,共5页
The full-bridge zero-voltage and zero-current switching inverter, which can adjust the output power by keeping the duty-cycle of lagging arm constant, changing the duty-cycle of leading arm, is a common circuit topolo... The full-bridge zero-voltage and zero-current switching inverter, which can adjust the output power by keeping the duty-cycle of lagging arm constant, changing the duty-cycle of leading arm, is a common circuit topology of soft-switching inverter arc welding power supplies. However, the output power still remains a certain value when the duty-cycle of leading arm decreases to zero. The working-mode of soft-switching inverter and the waveforms of major parameters with the condition of duty-cycle of leading arm being zero are studied in this paper. U-1 characteristic experiments prove that the minimum output power of soft-switching circuit, which depends on the charged voltage of capacitors in parallel with leading arm, can be decreased by reducing the duty-cycle of lagging arm. By switching working-modes between half-bridge and full-bridge, the output power can swing from zero to the power rating. 展开更多
关键词 soft-switchING inverter arc welding power supplies minimum output power
下载PDF
Principle and parameter design of arc welding inverter using soft switching technique
17
作者 陈树君 冯雷 +2 位作者 李亮玉 殷树言 张树田 《China Welding》 EI CAS 1998年第1期63-70,共8页
The soft switching are welding inverter reduces switching losses and improves operating environment of devices by using Zero-Voltage-Transition (ZVT) technique. Step-by-step analysis of each timing interval and the as... The soft switching are welding inverter reduces switching losses and improves operating environment of devices by using Zero-Voltage-Transition (ZVT) technique. Step-by-step analysis of each timing interval and the associating voltage and current waveforms are included for the Full-Bridge Zero-Voltage-Switched PWM converter. Numerous design equations supporting the phase-shifted soft switching technique are highlighted. 展开更多
关键词 soft switching arc welding inverter Zero-Voltage-Transition (ZVT) Zero-Voltage-switching (ZVS)
下载PDF
Soft switching arc welding power source using output inductor as resonant inductor
18
作者 陈树君 王军 +1 位作者 卢振洋 殷树言 《China Welding》 EI CAS 2002年第2期109-113,共5页
Full bridge Zero Voltage Switch PWM converter combines advantages of the PWM control technique and resonant technique. However, Full ZVS is achieved only under large load current because resonant tank of this circu... Full bridge Zero Voltage Switch PWM converter combines advantages of the PWM control technique and resonant technique. However, Full ZVS is achieved only under large load current because resonant tank of this circuit is made up of the parasitic capacitance of the power semiconductors and the leakage inductor of the transformer primary. In this paper two saturable inductors as magnetic switches are added to secondary, so output inductor is always reflected to primary and assists resonant transition. Full ZVS is achieved under lower load current. The above mentioned investigated results are validated by the computerized simulation and hardware circuit experiment. 展开更多
关键词 arc welding inverter power source soft switching resonant inductor computerized simulation
下载PDF
Controlling the output power of soft switching arc welding inverter by two-stage continuous PWM method
19
作者 傅强 赵善麒 范新南 《China Welding》 EI CAS 2016年第1期64-70,共7页
The full bridge zero voltage zero current switching ( FB-ZVZCS ) , which could adjust the output power by keeping the duty ratio of lagging leg constant and changing the duty ratio of leading leg, was a common circu... The full bridge zero voltage zero current switching ( FB-ZVZCS ) , which could adjust the output power by keeping the duty ratio of lagging leg constant and changing the duty ratio of leading leg, was a common circuit of soft switching arc welding inverter power source. However, when the duty ratio of leading leg was reduced to zero, the output power stayed the constant value instead of becoming zero. The working status and waveforms of some major parameters were studied in this paper while the duty ratio of leading leg was zero. It was concluded that the minimum output power of soft switching inverter was related to the charging voltage of paraUel capacitors, and the output power also could be reduced by reducing the duty ratio of lagging leg. A novel two-stage continuous PWM control method that could switch working-mode between full bridge and half bridge was put forward in this paper. This kind of control method could further reduce the output power of soft switching inverter in order to meet the requirement of low heat input of sheet metal welding. 展开更多
关键词 soft switching inverter arc welding power source minimum output power two stage continuous PWM control
下载PDF
Broad-Band All-Optical Wavelength Conversion of Differential Phase-Shift Keyed Signal Using an SOA-Based Nonlinear Polarization Switch
20
作者 毛雅亚 盛新志 +1 位作者 吴重庆 余贶碌 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第3期44-47,共4页
Broad-band all-optical wavelength conversion of differential phase-shift keyed (DPSK) signal is experimentally demonstrated. This scheme is composed of a one-bit delay interferometer demodulation stage followed by a... Broad-band all-optical wavelength conversion of differential phase-shift keyed (DPSK) signal is experimentally demonstrated. This scheme is composed of a one-bit delay interferometer demodulation stage followed by a semiconductor optical amplifier (SOA) based nonlinear polarization switch. A wavelength converter for the 10 G b/s DPSK signal is presented, which has a wide wavelength range of more than 30 nm. The converted signals experience small power penalties less than 1.4 dB compared with the original signal, at a bit error rate of 10-9. Additionally, the optical spectra, the measured waveforms and the open eye diagrams of the converted signals show a high quality wavelength conversion performance. 展开更多
关键词 SOA for length as is of Broad-Band All-Optical Wavelength Conversion of Differential phase-shift Keyed Signal Using an SOA-Based Nonlinear Polarization switch DPSK
下载PDF
上一页 1 2 144 下一页 到第
使用帮助 返回顶部