The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo- geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography...The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo- geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography to enhance the photoacoustic tomography in this situation. The speed-of-sound information is recovered by ultrasound computed to- mography. Then, an improved delay-and-sum method is used to reconstruct the image from the photoacoustic signals. The simulation results validate that the proposed method can obtain a better photoacoustic tomography than the conventional method when the speed-of-sound variance is increased. In addition, the influences of the speed-of-sound variance and the fan-angle on the image quality are quantitatively explored to optimize the image scheme. The proposed method has a good performance even when the speed-of-sound variance reaches 14.2%. Furthermore, an optimized fan angle is revealed, which can keep the good image quality with a low cost of hardware. This study has a potential value in extending the biomedical application of photoacoustic tomography.展开更多
Based on the energy conversion of light into sound,photoacoustic computed tomography(PACT)is an emerging biomedical imaging modality and has unique applications in a range of biomedical fields.In PACT,image formation ...Based on the energy conversion of light into sound,photoacoustic computed tomography(PACT)is an emerging biomedical imaging modality and has unique applications in a range of biomedical fields.In PACT,image formation relies on a process called acoustic inversion from received photoacoustic signals.While most PACT systems perform this inversion with a basic assumption that biological tissues are acoustically homogeneous,the community gradually rea-lizes that the intrinsic acoustic heterogeneity of tissues could pose distortions and artifacts to finally formed images.This paper surveys the most recent research progress on acoustic het-erogeneity correction in PACT.Four major strategies are reviewed in detail,including half-time or partial-time reconstruction,autofocus reconstruction by optimizing sound speed maps,joint reconstruction of optical absorption and sound speed maps,and ultrasound computed tomog-raphy(USCT)enhanced reconstruction.The correction of acoustic heterogeneity helps improve the imaging performance of PACT.展开更多
Photoacoustic imag ing(PAI)is a nonin vasive biomedical imag ing tech no logy capable of multiscale imag ing of biological samples from orga ns dow n to cells.Multiscale PAI requires differe nt ultraso und tra nsducer...Photoacoustic imag ing(PAI)is a nonin vasive biomedical imag ing tech no logy capable of multiscale imag ing of biological samples from orga ns dow n to cells.Multiscale PAI requires differe nt ultraso und tra nsducers that are flat or focused because the current widely-used piezoelectric transducers are rigid and lack the flexibility to tune their spatial ultrasound responses.Inspired by the rapidly-developing flexible photonics,we exploited the inherent flexibility and low-loss features of optical fibers to develop a flexible fiber-laser ultrasound sensor(FUS)for multiscale PAI.By simply bending the fiber laser from straight to curved geometry,the spatial ultraso und resp onse of the FUS can be tuned for both wide-view optical-resolution photoacoustic microscopy at optical diffraction-limited depth(~1 mm)and photoacoustic computed tomography at optical dissipation-limited depth of several centimeters.A radio-frequency demodulation was employed to get the readout of the beat frequency variation of two orthogonal polarization modes in the FUS output,which ensures low-noise and stable ultrasound detection.Compared to traditional piezoelectrical transducers with fixed ultrasound responses once manufactured,the flexible FUS provides the freedom to design multiscale PAI modalities including wearable microscope,intravascular endoscopy,and portable tomography system,which is attractive to fundamental biologic-al/medical studies and clinical applications.展开更多
基金supported by the National Basic Research Program of China(Grant No.2012CB921504)the National Natural Science Foundation of China(Grant Nos.11422439,11274167,and 11274171)the Specialized Research Fund for the Doctoral Program of Higher Education,China(Grant No.20120091110001)
文摘The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo- geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography to enhance the photoacoustic tomography in this situation. The speed-of-sound information is recovered by ultrasound computed to- mography. Then, an improved delay-and-sum method is used to reconstruct the image from the photoacoustic signals. The simulation results validate that the proposed method can obtain a better photoacoustic tomography than the conventional method when the speed-of-sound variance is increased. In addition, the influences of the speed-of-sound variance and the fan-angle on the image quality are quantitatively explored to optimize the image scheme. The proposed method has a good performance even when the speed-of-sound variance reaches 14.2%. Furthermore, an optimized fan angle is revealed, which can keep the good image quality with a low cost of hardware. This study has a potential value in extending the biomedical application of photoacoustic tomography.
基金supported in part by the National Natural Science Foundation of China(NSFC)under Grant No.61705216in part by the Major Science and Technology Project of Anhui Province under Grant No.18030801138+4 种基金in part by the Zhe-jiang Lab under Grant No.2019MC0AB01in part by the Research Funds of the Double First-Class Initiativein part by the Research Fund of the USTC Smart City Institutein part by the CAS Pioneer Hundred Talents Programin part by the Startup Fund of the University of Science and Technology of China(USTC)
文摘Based on the energy conversion of light into sound,photoacoustic computed tomography(PACT)is an emerging biomedical imaging modality and has unique applications in a range of biomedical fields.In PACT,image formation relies on a process called acoustic inversion from received photoacoustic signals.While most PACT systems perform this inversion with a basic assumption that biological tissues are acoustically homogeneous,the community gradually rea-lizes that the intrinsic acoustic heterogeneity of tissues could pose distortions and artifacts to finally formed images.This paper surveys the most recent research progress on acoustic het-erogeneity correction in PACT.Four major strategies are reviewed in detail,including half-time or partial-time reconstruction,autofocus reconstruction by optimizing sound speed maps,joint reconstruction of optical absorption and sound speed maps,and ultrasound computed tomog-raphy(USCT)enhanced reconstruction.The correction of acoustic heterogeneity helps improve the imaging performance of PACT.
基金This work was supported by the National Natural Science Foundation of China(61775083,61705082,61805102,and 61860206002)the Local Innovative and Research Teams Project of Guangdong Pearl River Talents Program(2019BT02X105)Guangzhou Science and Technology Plan(201904020032).
文摘Photoacoustic imag ing(PAI)is a nonin vasive biomedical imag ing tech no logy capable of multiscale imag ing of biological samples from orga ns dow n to cells.Multiscale PAI requires differe nt ultraso und tra nsducers that are flat or focused because the current widely-used piezoelectric transducers are rigid and lack the flexibility to tune their spatial ultrasound responses.Inspired by the rapidly-developing flexible photonics,we exploited the inherent flexibility and low-loss features of optical fibers to develop a flexible fiber-laser ultrasound sensor(FUS)for multiscale PAI.By simply bending the fiber laser from straight to curved geometry,the spatial ultraso und resp onse of the FUS can be tuned for both wide-view optical-resolution photoacoustic microscopy at optical diffraction-limited depth(~1 mm)and photoacoustic computed tomography at optical dissipation-limited depth of several centimeters.A radio-frequency demodulation was employed to get the readout of the beat frequency variation of two orthogonal polarization modes in the FUS output,which ensures low-noise and stable ultrasound detection.Compared to traditional piezoelectrical transducers with fixed ultrasound responses once manufactured,the flexible FUS provides the freedom to design multiscale PAI modalities including wearable microscope,intravascular endoscopy,and portable tomography system,which is attractive to fundamental biologic-al/medical studies and clinical applications.
基金supported by the Anhui Provincial Department of Science and Technology(18030801138)the National Natural Science Foundation of China(61705216,12174368,62122072)the Zhejiang Lab(2019MC0AB01)。