A different approach,using the molecular beam epitaxy (MBE)-grown ZnS-based Schottky photodiode technology,is applied to fabricate an 8×8 photodiode array.The micro-processing procedures of this photodiode array ...A different approach,using the molecular beam epitaxy (MBE)-grown ZnS-based Schottky photodiode technology,is applied to fabricate an 8×8 photodiode array.The micro-processing procedures of this photodiode array including standard photolithography,a number of metallisation,wet-chemical etching and SiO_2 deposition for insulation are developed.The detector is characterized to have a cutoff wavelength at 340 nm and the photo-responsivity measurements on the pixels result an ultraviolet (UV) response as high as 0.15 A/W,corresponding to an external quantum efficiency of 55% in the visible-blind spectral ranging from 400 down to 250nm.Imaging tests indicate that this array is able to capture the intensity profile of a given UV light source with reasonably good capability.展开更多
Quantum random number generators adopting single negligible dead time of avalanche photodiodes (APDs) photon detection have been restricted due to the non- We propose a new approach based on an APD array to improve...Quantum random number generators adopting single negligible dead time of avalanche photodiodes (APDs) photon detection have been restricted due to the non- We propose a new approach based on an APD array to improve the generation rate of random numbers significantly. This method compares the detectors' responses to consecutive optical pulses and generates the random sequence. We implement a demonstration experiment to show its simplicity, compactness and scalability. The generated numbers are proved to be unbiased, post-processing free, ready to use, and their randomness is verified by using the national institute of standard technology statistical test suite. The random bit generation efficiency is as high as 32.8% and the potential generation rate adopting the 32× 32 APD array is up to tens of Gbits/s.展开更多
A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consis...A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consists of isocratic eluation with a mixture of 60% buffer (10 mM sodium dihyrogenphosphate-10 mM sodium dodecyl sulphate) and 40% acetonitrile with final pH 7.0 with flow rate of 1.0 mL/min on a Kromasil~ Akzo Nobel RP-18 (4.6 mm ID ~ 250 mm, 5 ~tm) column at an ambient temperature. Photo diode array detection was performed in program mode at 234 rim. The analyte and diazepam as internal standard (IS) were extracted from plasma using 10% trichloroacetic acid. The assay was linear over the therapeutic concentration range of 20-2,500 ng/mL for metformin HCI with correlation coefficient of r = 0.9999. Limit of quantitation was 20 ng/mL. The results obtained for intraJinter day accuracy and precision complied very well with the generally accepted criteria for bio-analytical assay. The method was applied to bioequivalence (BE) study of metformin HCI in healthy Indonesian volunteers after treatment with 750 mg XR metformin HCI. This BE study shows that the two formulations are equivalent so that they were therapeutically interchangeable for each other.展开更多
Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quant...Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quantum efficiency of the detectors in the 2D array deteriorate the imaging quality.Herein,we propose a photon-counting LiDAR system that uses a spatial light modulator to control the spatial intensity to compensate for both the non-uniform intensity profile of the illumination beam,and the variation in the quantum efficiency of the detectors in the 2D array.By using a 635 nm peak wavelength and 4 mW average power semiconductor laser,lab-based experiments at a 4.27 m stand-off distance are performed to verify the effectiveness of the proposed method.Compared with the unmodulated method,the standard deviation of the intensity image of the proposed method is reduced from 0.109 to 0.089 for a whiteboard target,with an average signal photon number of 0.006 per pixel.展开更多
Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is conve...Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is convenient to be arranged in experiment. With the PDA system, the particle confinement time (τp) has been systematically investigated. The relations such as τp on the center-line-averaged electron density (ne), τp on plasma current (Ip), and τp, on the toroidal magnetic field (Bt) have been obtained. The particle confinement under the Ion Berstain Wave (IBW) Heating has also been measured and analyzed.展开更多
We have designed and fabricated zero-bias operational two-element symmetric-connected photodetector arrays(SC-PDAs).The designed SC-PDAs have higher saturation currents,larger RF power,and better frequency responses t...We have designed and fabricated zero-bias operational two-element symmetric-connected photodetector arrays(SC-PDAs).The designed SC-PDAs have higher saturation currents,larger RF power,and better frequency responses than the single photodetector(PD)under zero bias.The bias-free SC-PDA with 15μm diameter of each PD demonstrated a 3 d B bandwidth of 19.4 GHz at 0.5 m A.The RF saturation photocurrent and maximum RF output power of the SC-PDA with 40μm,50μm,and 60μm diameters under zero bias are over9.31 m A and-5.86 d Bm at 3 GHz,14.52 m A and 1.17 d Bm at 1 GHz,and 13.72 m A and-1.76 d Bm at 1 GHz,respectively.展开更多
文摘A different approach,using the molecular beam epitaxy (MBE)-grown ZnS-based Schottky photodiode technology,is applied to fabricate an 8×8 photodiode array.The micro-processing procedures of this photodiode array including standard photolithography,a number of metallisation,wet-chemical etching and SiO_2 deposition for insulation are developed.The detector is characterized to have a cutoff wavelength at 340 nm and the photo-responsivity measurements on the pixels result an ultraviolet (UV) response as high as 0.15 A/W,corresponding to an external quantum efficiency of 55% in the visible-blind spectral ranging from 400 down to 250nm.Imaging tests indicate that this array is able to capture the intensity profile of a given UV light source with reasonably good capability.
基金Supported by the Chinese Academy of Sciences Center for Excellence and Synergetic Innovation Center in Quantum Information and Quantum Physics,Shanghai Branch,University of Science and Technology of Chinathe National Natural Science Foundation of China under Grant No 11405172
文摘Quantum random number generators adopting single negligible dead time of avalanche photodiodes (APDs) photon detection have been restricted due to the non- We propose a new approach based on an APD array to improve the generation rate of random numbers significantly. This method compares the detectors' responses to consecutive optical pulses and generates the random sequence. We implement a demonstration experiment to show its simplicity, compactness and scalability. The generated numbers are proved to be unbiased, post-processing free, ready to use, and their randomness is verified by using the national institute of standard technology statistical test suite. The random bit generation efficiency is as high as 32.8% and the potential generation rate adopting the 32× 32 APD array is up to tens of Gbits/s.
文摘A sensitive and specific high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of metformin hydrochloride (HCI) in human plasma. The HPLC method consists of isocratic eluation with a mixture of 60% buffer (10 mM sodium dihyrogenphosphate-10 mM sodium dodecyl sulphate) and 40% acetonitrile with final pH 7.0 with flow rate of 1.0 mL/min on a Kromasil~ Akzo Nobel RP-18 (4.6 mm ID ~ 250 mm, 5 ~tm) column at an ambient temperature. Photo diode array detection was performed in program mode at 234 rim. The analyte and diazepam as internal standard (IS) were extracted from plasma using 10% trichloroacetic acid. The assay was linear over the therapeutic concentration range of 20-2,500 ng/mL for metformin HCI with correlation coefficient of r = 0.9999. Limit of quantitation was 20 ng/mL. The results obtained for intraJinter day accuracy and precision complied very well with the generally accepted criteria for bio-analytical assay. The method was applied to bioequivalence (BE) study of metformin HCI in healthy Indonesian volunteers after treatment with 750 mg XR metformin HCI. This BE study shows that the two formulations are equivalent so that they were therapeutically interchangeable for each other.
文摘Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quantum efficiency of the detectors in the 2D array deteriorate the imaging quality.Herein,we propose a photon-counting LiDAR system that uses a spatial light modulator to control the spatial intensity to compensate for both the non-uniform intensity profile of the illumination beam,and the variation in the quantum efficiency of the detectors in the 2D array.By using a 635 nm peak wavelength and 4 mW average power semiconductor laser,lab-based experiments at a 4.27 m stand-off distance are performed to verify the effectiveness of the proposed method.Compared with the unmodulated method,the standard deviation of the intensity image of the proposed method is reduced from 0.109 to 0.089 for a whiteboard target,with an average signal photon number of 0.006 per pixel.
文摘Photo Diode Array (PDA) has been successfully applied in HT-7 tokamak experiments. The PDA system is almost free of electromagnetic interference from the machine. The system is compact and inexpensive, and it is convenient to be arranged in experiment. With the PDA system, the particle confinement time (τp) has been systematically investigated. The relations such as τp on the center-line-averaged electron density (ne), τp on plasma current (Ip), and τp, on the toroidal magnetic field (Bt) have been obtained. The particle confinement under the Ion Berstain Wave (IBW) Heating has also been measured and analyzed.
基金This work was supported by the National Natural Science Foundation of China(NSFC)(Nos.61574019,61674018,61674020,and 61874147)the Fund of State Key Laboratory of Information Photonics and Optical Communications,and the Specialized Research Fund for the Doctoral Program of Higher Education of China(No.20130005130001).
文摘We have designed and fabricated zero-bias operational two-element symmetric-connected photodetector arrays(SC-PDAs).The designed SC-PDAs have higher saturation currents,larger RF power,and better frequency responses than the single photodetector(PD)under zero bias.The bias-free SC-PDA with 15μm diameter of each PD demonstrated a 3 d B bandwidth of 19.4 GHz at 0.5 m A.The RF saturation photocurrent and maximum RF output power of the SC-PDA with 40μm,50μm,and 60μm diameters under zero bias are over9.31 m A and-5.86 d Bm at 3 GHz,14.52 m A and 1.17 d Bm at 1 GHz,and 13.72 m A and-1.76 d Bm at 1 GHz,respectively.