期刊文献+
共找到1,921篇文章
< 1 2 97 >
每页显示 20 50 100
Development of an Integrated Disposable Device for SARSCoV-2 Nucleic Acid Extraction and Detection
1
作者 Jing Ma Yanzhe Hao +11 位作者 Meiling Hou Xiaoshan Zhang Jingduan Liu Haodi Meng Jiangbo Chang Xuejun Ma Jihua Liu Qingjie Ying Xianhua Wang Hongxia Li Yuxi Cao Xiaoguang Zhang 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2024年第6期639-646,共8页
Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods We designed,developed,and manufactured an integrated disposab... Objective To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2(SARS-CoV-2).Methods We designed,developed,and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection.The precision of the liquid transfer and temperature control was tested.A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction(RT-PCR).The entire process,from SARS-CoV-2 nucleic acid extraction to amplification,was evaluated.Results The precision of the syringe transfer volume was 19.2±1.9μL(set value was 20),32.2±1.6(set value was 30),and 57.2±3.5(set value was 60).Temperature control in the amplification tube was measured at 60.0±0.0℃(set value was 60)and 95.1±0.2℃(set value was 95)respectively.SARS-Cov-2 nucleic acid extraction yield through the device was 7.10×10^(6) copies/mL,while a commercial kit yielded 2.98×10^(6) copies/mL.The mean time to complete the entire assay,from SARS-CoV-2 nucleic acid extraction to amplification detection,was 36 min and 45 s.The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL.Conclusion The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test(POCT). 展开更多
关键词 An integrated disposable device SARS-Cov-2 Nucleic acid detection
下载PDF
Integrated device for multiscale series vibration reduction and energy harvesting 被引量:1
2
作者 Jihou YANG Weixing ZHANG Xiaodong YANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2023年第12期2227-2242,共16页
A multi-degree-of-freedom device is proposed,which can achieve efficient vibration reduction as the main objective and energy harvesting as the secondary purpose.The device comprises a multiscale nonlinear vibration a... A multi-degree-of-freedom device is proposed,which can achieve efficient vibration reduction as the main objective and energy harvesting as the secondary purpose.The device comprises a multiscale nonlinear vibration absorber(NVA)and piezoelectric components.Energy conversion and energy measurement methods are used to evaluate the device performance from multiple perspectives.Research has shown that this device can efficiently transfer transient energy from the main structure and convert a portion of transient energy into electrical energy.Main resonance and higher-order resonance are the main reasons for efficient energy transfer.The device can maintain high vibration reduction performance even when the excitation amplitude changes over a large range.Compared with the single structures with and without precompression,the multiscale NVA-piezoelectric device offers significant vibration reduction advantages.In addition,there are significant differences in the parameter settings of the two substructures for vibration reduction and energy harvesting. 展开更多
关键词 integrated device nonlinear vibration reduction energy harvesting transient vibration energy principle
下载PDF
Analysis of the integrated test and evaluation methods of tidal current energy generating devices in the offshore testing site
3
作者 郭文瑞 朱永强 +3 位作者 叶青 李雪临 王鑫 段春明 《Marine Science Bulletin》 CAS 2014年第2期60-71,共12页
Actual sea condition testing and inspection and evaluation method research are carried out for tidal energy devices to provide scientific and effective technical support for the ocean high-tech achievement transformat... Actual sea condition testing and inspection and evaluation method research are carried out for tidal energy devices to provide scientific and effective technical support for the ocean high-tech achievement transformation and marine renewable energy development. By analyzing three core indicators, including the power output characteristics of the tidal current device, the generating capacity, energy conversion efficiency, proposed the test contents and evaluation methods of indicators are proposed in this paper; and based on the research of wind farms, power quality testing and assessment methods of offshore tidal energy device are proposed; given the security access to the test contents of tidal current energy device, tidal current energy device running conditions in the testing ground are comprehensively assessed. 展开更多
关键词 testing ground tidal current energy generating device integrated test evaluation method
下载PDF
A Literature Review: Potential Effects That Health Apps on Mobile Devices May Have on Patient Privacy and Confidentiality
4
作者 Anna Sheri George Jomin George Judy Jenkins 《E-Health Telecommunication Systems and Networks》 2024年第3期23-44,共22页
Purpose: This research aims to evaluate the potential threats to patient privacy and confidentiality posed by mHealth applications on mobile devices. Methodology: A comprehensive literature review was conducted, selec... Purpose: This research aims to evaluate the potential threats to patient privacy and confidentiality posed by mHealth applications on mobile devices. Methodology: A comprehensive literature review was conducted, selecting eighty-eight articles published over the past fifteen years. The study assessed data gathering and storage practices, regulatory adherence, legal structures, consent procedures, user education, and strategies to mitigate risks. Results: The findings reveal significant advancements in technologies designed to safeguard privacy and facilitate the widespread use of mHealth apps. However, persistent ethical issues related to privacy remain largely unchanged despite these technological strides. 展开更多
关键词 Mobile devices Patient Privacy Confidentiality Breaches Data Security Data Protection Regulatory Compliance User Consent Data Encryption Third-Party integration User Awareness
下载PDF
Reliability analysis for vertical integration of protection,measurement,merge unit,and intelligent terminal device 被引量:1
5
作者 Ying Li Weiquan Wang +3 位作者 Liang Zhang Zhujian Liang Zhenli Xu Yuansheng Liang 《Global Energy Interconnection》 EI CSCD 2023年第6期772-784,共13页
The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a fo... The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a four-inone vertically integrated device and the information transmission path of each function based on the functional information transmission chain of protection devices,measurement and control devices,merging units,and intelligent terminals.Additionally,a reliability analysis model of the protection device and its protection system is constructed using the fault tree analysis method while considering the characteristics of each module of the vertically integrated device.The stability probability of the protection system in each state is analyzed by combining the state-transfer equations of line and busbar protection with a Markov chain.Finally,the failure rate and availability of the protection device and its protection system are calculated under different ambient temperatures using a 110 kV intelligent substation as an example.The sensitivity of each device module is analyzed. 展开更多
关键词 Vertical integration of secondary system device Reliability of secondary system IEC 61850-based substation Relay protection
下载PDF
Integrated System of Solar Cells with Hierarchical NiCo2O4 Battery-Supercapacitor Hybrid Devices for Self-Driving Light-Emitting Diodes 被引量:5
6
作者 Yuliang Yuan Yangdan Lu +10 位作者 BeiEr Jia Haichao Tang Lingxiang Chen YuJia Zeng Yang Hou Qinghua Zhang Qinggang He Lei Jiao Jianxing Leng Zhizhen Ye Jianguo Lu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2019年第3期92-103,共12页
An integrated system has been provided with a-Si/H solar cells as energy conversion device,NiCo2O4 battery-supercapacitor hybrid(BSH)as energy storage device,and light emitting diodes(LEDs)as energy utilization device... An integrated system has been provided with a-Si/H solar cells as energy conversion device,NiCo2O4 battery-supercapacitor hybrid(BSH)as energy storage device,and light emitting diodes(LEDs)as energy utilization device.By designing three-dimensional hierarchical NiCo2O4 arrays as faradic electrode,with capacitive electrode of active carbon(AC),BSHs were assembled with energy density of 16.6 Wh kg-1,power density of 7285 W kg-1,long-term stability with 100% retention after 15,000 cycles,and rather low self-discharge.The NiCo2O4//AC BSH was charged to 1.6 V in 1 s by solar cells and acted as reliable sources for powering LEDs.The integrated system is rational for operation,having an overall efficiency of 8.1% with storage efficiency of 74.24%.The integrated system demonstrates a stable solar power conversion,outstanding energy storage behavior,and reliable light emitting.Our study offers a precious strategy to design a self-driven integrated system for highly efficient energy utilization. 展开更多
关键词 integrated system NiCo2O4 Battery-supercapacitor hybrid devices SELF-DRIVING LED
下载PDF
Design and Application of Water, Fertilizer and Pesticide Integrated Automatic Control Device 被引量:4
7
作者 Huang Wei Lu Meiling +2 位作者 Liang Xin Zhu Yulin Wang Daobo 《Plant Diseases and Pests》 CAS 2020年第1期30-32,共3页
Integration of water, fertilizer and pesticide is the final stage of agricultural development, which improves the utilization efficiency of water, fertilizer and pesticide. Starting from the design and realization of ... Integration of water, fertilizer and pesticide is the final stage of agricultural development, which improves the utilization efficiency of water, fertilizer and pesticide. Starting from the design and realization of water, fertilizer and pesticide integrated automatic control device, the paper discusses selection and application of fertilizer pesticides, use procedure, water, fertilizer and pesticide saving effect and receptive crowd in the application process of modern planting industry, so as to provide the basis for promotion and popularization of water, fertilizer and pesticide integration. 展开更多
关键词 AUTOMATIC control device integrATION WATER FERTILIZER PESTICIDE
下载PDF
Photoic crystal nanobeam cavity devices for on-chip integrated silicon photonics 被引量:2
8
作者 Daquan Yang Xiao Liu +3 位作者 Xiaogang Li Bing Duan Aiqiang Wang Yunfeng Xiao 《Journal of Semiconductors》 EI CAS CSCD 2021年第2期40-50,共11页
Integrated circuit(IC)industry has fully considered the fact that the Moore’s Law is slowing down or ending.Alternative solutions are highly and urgently desired to break the physical size limits in the More-than-Moo... Integrated circuit(IC)industry has fully considered the fact that the Moore’s Law is slowing down or ending.Alternative solutions are highly and urgently desired to break the physical size limits in the More-than-Moore era.Integrated silicon photonics technology exhibits distinguished potential to achieve faster operation speed,less power dissipation,and lower cost in IC industry,because their COMS compatibility,fast response,and high monolithic integration capability.Particularly,compared with other on-chip resonators(e.g.microrings,2D photonic crystal cavities)silicon-on-insulator(SOI)-based photonic crystal nanobeam cavity(PCNC)has emerged as a promising platform for on-chip integration,due to their attractive properties of ultra-high Q/V,ultra-compact footprints and convenient integration with silicon bus-waveguides.In this paper,we present a comprehensive review on recent progress of on-chip PCNC devices for lasing,modulation,switching/filting and label-free sensing,etc. 展开更多
关键词 PCNC integrated silicon photonics More-than-Moore LAB-ON-A-CHIP hybrid devices
下载PDF
Enhancement of electroluminescent properties of organic optoelectronic integrated device by doping phosphorescent dye 被引量:1
9
作者 雷疏影 钟建 +2 位作者 周殿力 朱方云 邓朝旭 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第11期434-440,共7页
Organic optoelectronic integrated devices(OIDs) with ultraviolet(UV) photodetectivity and different color emitting were constructed by using a thermally activated delayed fluorescence(TADF) material 4, 5-bis(ca... Organic optoelectronic integrated devices(OIDs) with ultraviolet(UV) photodetectivity and different color emitting were constructed by using a thermally activated delayed fluorescence(TADF) material 4, 5-bis(carbazol-9-yl)-1, 2-dicyanobenzene(2 CzPN) as host. The OIDs doping with typical red phosphorescent dye [tris(1-phenylisoquinoline)iridium(Ⅲ), Ir(piq)3], orange phosphorescent dye {bis[2-(4-tertbutylphenyl)benzothiazolato-N,C-(2')]iridium(acetylacetonate),(tbt)2 Ir(acac)}, and blue phosphorescent dye [bis(2, 4-di-fluorophenylpyridinato)-tetrakis(1-pyrazolyl)borate iridium(Ⅲ), FIr6] were investigated and compared. The(tbt)2 Ir(acac)-doped orange device showed better performance than those of red and blue devices, which was ascribed to more effective energy transfer. Meanwhile, at a low dopant concentration of 3 wt.%, the(tbt)2 Ir(acac)-doped OIDs showed the maximum luminance, current efficiency, power efficiency of 70786 cd/m^2, 39.55 cd/A, and 23.92 lm/W, respectively, and a decent detectivity of 1.07 × 10^11 Jones at a bias of -2 V under the UV-350 nm illumination. This work may arouse widespread interest in constructing high efficiency and luminance OIDs based on doping phosphorescent dye. 展开更多
关键词 organic optoelectronic integrated device thermally activated delayed fluorescence host phosphorescent dye high luminance
下载PDF
Design and dynamic analysis of single-axis integrated inertia measurement device 被引量:2
10
作者 Ma Zongmin Shi Yunbo +1 位作者 Meng Meiyu Liu Jun 《仪器仪表学报》 EI CAS CSCD 北大核心 2007年第9期1558-1563,共6页
The structure and measurement theory of a single-axis integrated inertia measurement device are discussed in this paper.The acceleration and angle velocity can be detected by the proposed sensor at the same time.The k... The structure and measurement theory of a single-axis integrated inertia measurement device are discussed in this paper.The acceleration and angle velocity can be detected by the proposed sensor at the same time.The ki- netic model of the device is also established.In addition,the signal generation of the single-axis integrated inertia measurement device is analyzed and simulated.The results of the model are consistent with simulation result. 展开更多
关键词 设计 动力学模型 单轴整合 惯性测量仪器 仿真分析
下载PDF
Modern Monitoring Intraocular Pressure Sensing Devices Based on Application Specific Integrated Circuits
11
作者 Daniel Piso Patricia Veiga-Crespo Elena Vecino 《Journal of Biomaterials and Nanobiotechnology》 2012年第2期301-309,共9页
Glaucoma is a neurodegenerative condition that is the leading cause of irreversible blindness worldwide. Elevated intraocular pressure (IOP) is the main risk factor for the development and progression of the disease. ... Glaucoma is a neurodegenerative condition that is the leading cause of irreversible blindness worldwide. Elevated intraocular pressure (IOP) is the main risk factor for the development and progression of the disease. Methods to lower IOP remain the first line treatments for the condition. Current methods of IOP measurement do not permit temporary noninvasive monitoring 24-hour IOP on a periodic basis. Ongoing research will in time provide a means of developing a device that will enable continuous or temporary monitoring of IOP. At present a device suitable for clinical use is not yet available.This review contains a description of different devices currently in development for measuring IOP: soft contact lens, LC resonant circuits and on-chip sensing devices. All of them use application-specific integrated circuits (ASICS) to process the measured signals and send them to recording devices. Soft contact lens devices are based on an embedded strain gauge, LC circuits vary their resonance frequency depending on the intraocular pressure (IOP) and, finally, on-chip sensing devices include an integrated microelectromechanical sensor (MEMS). MEMS are capacitors whose capacity varies with IOP. These devices allow for an accurate IOP measurement (up to +/– 0.2 mm Hg) with high sampling rates (up to 1 sample/min) and storing 1 week of raw data. All of them operate in an autonomous way and even some of them are energetically independent. 展开更多
关键词 GLAUCOMA INTRAOCULAR Pressure MONITORING IMPLANTABLE device Application-Specific integrated CIRCUIT
下载PDF
Creating Distinctive Connections between Multifunctional Microwave Circuits and Mobile-Terminal Radio-Frequency Integrated Chips Using Integrated Passive Device Technology
12
作者 Yongle Wu Mengdan Kong +1 位作者 Zheng Zhuang Weimin Wang 《China Communications》 SCIE CSCD 2021年第8期121-132,共12页
In this review,the advanced microwave devices based on the integrated passive device(IPD)technology are expounded and discussed in detail,involving the performance breakthroughs and circuit innovations.Then,the develo... In this review,the advanced microwave devices based on the integrated passive device(IPD)technology are expounded and discussed in detail,involving the performance breakthroughs and circuit innovations.Then,the development trend of IPD-based multifunctional microwave circuits is predicted further by analyzing the current research hot spots.This paper discusses a distinctive research area for microwave circuits and mobile-terminal radio-frequency integrated chips. 展开更多
关键词 CHIPS integrated passive device(IPD) MULTIFUNCTIONAL microwave circuit
下载PDF
Device Physics Research for Submicron and Deep Submicron Space Microelectronics Devices and Integrated Circuits
13
作者 Huang Chang, Yang Yinghua, Yu Shan, Zhang Xing, Xu Jun, Lu Quan, Chen Da 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1992年第4期3-4,6-2,共4页
Device physics research for submicron and deep submicron space microelectronics devices and integrated circuits will be described in three topics.1.Thin film submicron and deep submicron SOS / CMOS devices and integra... Device physics research for submicron and deep submicron space microelectronics devices and integrated circuits will be described in three topics.1.Thin film submicron and deep submicron SOS / CMOS devices and integrated circuits.2.Deep submicron LDD CMOS devices and integrated circuits.3.C band and Ku band microwave GaAs MESFET and III-V compound hetrojunction HEM T and HBT devices and integrated circuits. 展开更多
关键词 GaAs MESFET CMOS device Physics Research for Submicron and Deep Submicron Space Microelectronics devices and integrated Circuits MOSFET length
下载PDF
The Anneal Temperature Effect on the BTO and NZFO Films and Their Capacitance-Inductance Integrated Device
14
作者 Zhen Zheng Yuhao Shi +1 位作者 Chengjie Shi Chunqing Wang 《Semiconductor Science and Information Devices》 2019年第1期2-7,共6页
In this paper,a novel capacitor-inductor integrated structure was proposed.The dielectric material BaTiO3(BTO)and ferromagnetic material Ni0.5Zn0.5Fe2O4(NZFO)was prepared by sol-gel method.Phase composition and morpho... In this paper,a novel capacitor-inductor integrated structure was proposed.The dielectric material BaTiO3(BTO)and ferromagnetic material Ni0.5Zn0.5Fe2O4(NZFO)was prepared by sol-gel method.Phase composition and morphology of the thin films were characterized by XRD,SEM and AFM.The effect of annealing temperature on film crystallinity,surface morphology,dielectric properties and ferromagnetism was investigated.When the annealing temperature was 700°C,the BTO film and the NZFO film got the better dielectric properties and ferromagnetic properties.Then the BTO thin film was spin-coated on the substrate,and the NZFO thin film was in-situ sintered on the BTO thin film.The composite film possessed both ferromagnetism and dielectric properties.Finally,an inductive coil was fabricated on the BTO/NZFO composite film to produce a capacitance and inductance integrated device. 展开更多
关键词 Capacitor-inductor integrated device BTO FILM NZFO FILM ANNEAL temperature
下载PDF
Noise analysis and measurement of time delay and integration charge coupled device 被引量:4
15
作者 王德江 张涛 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第8期348-353,共6页
Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the comp... Time delay and integration (TDI) charge coupled device (CCD) noise sets a fundamental limit on image sensor performance, especially under low illumination in remote sensing applications. After introducing the complete sources of CCD noise, we study the effects of TDI operation mode on noise, and the relationship between different types of noise and number of the TDI stage. Then we propose a new technique to identify and measure sources of TDI CCD noise employing mathematical statistics theory, where theoretical analysis shows that noise estimated formulation converges well. Finally, we establish a testing platform to carry out experiments, and a standard TDI CCD is calibrated by using the proposed method. The experimental results show that the noise analysis and measurement methods presented in this paper are useful for modeling TDI CCDs. 展开更多
关键词 time delay and integration charge coupled device noise measurement remote sensingapplication
下载PDF
In-plane micro-sized energy storage devices:From device fabrication to integration and intelligent designs 被引量:2
16
作者 Songshan Bi Hongmei Cao +2 位作者 Rui Wang Fang Wan Zhiqiang Niu 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2021年第12期25-39,I0002,共16页
The rapid development of micro-electronics raises the demand of their power sources to be simplified,miniaturized and highly integratable with other electronics on a chip.In-plane Micro-sized energy storage devices(ME... The rapid development of micro-electronics raises the demand of their power sources to be simplified,miniaturized and highly integratable with other electronics on a chip.In-plane Micro-sized energy storage devices(MESDs),which are composed of interdigitated electrodes on a single chip,have aroused particular attentions since they could be easily integrated with other miniaturized electronics,reducing the complexity of overall chip design via removing complex interconnections with bulky power sources.This review highlights the achievements in the device fabrication of in-plane MESDs,as well as their integration and intelligent designs.We also discussed the current challenges and future perspectives for the development of in-plane MESDs. 展开更多
关键词 Micro-sized energy storage devices Micro-batteries Micro-supercapacitors integrATION Intelligent designs
下载PDF
Integrity Assessment of Medical Devices for Improving Hospital Services 被引量:3
17
作者 Fahad A.Alzahrani Masood Ahmad +2 位作者 Mohd Nadeem Rajeev Kumar Raees Ahmad Khan 《Computers, Materials & Continua》 SCIE EI 2021年第6期3619-3633,共15页
The present study examines the various techniques being used to maintain the integrity of the medical devices,and develops a quantitative framework to list these in the sequence of priority.To achieve the intended obj... The present study examines the various techniques being used to maintain the integrity of the medical devices,and develops a quantitative framework to list these in the sequence of priority.To achieve the intended objective,the study employs the combined procedure of Fuzzy Analytic Network Process(ANP)and Fuzzy Technical for Order Preference by Similarities to Ideal Solution(TOPSIS).We selected fuzzy based decision making techniques for assessing the integrity of medical devices.The suggested methodology was then used for classifying the suitable techniques used to evaluate the integrity of medical devices.Different techniques or the procedures of integrity assessment were ranked according to their satisfaction weights.The rating of the options determined the order of priority for the procedures.As per the findings of the study,among all the options,A1 was assessed to be the most likely option.This means that the integrity of medical devices of A2 is the highest amongst all the chosen alternatives.This analysis will be a corroborative guideline for manufacturers and developers to quantitatively test the integrity of medical devices in order to engineer efficacious devices.The evaluations undertaken with the assistance of the planned procedure are accurate and conclusive.Hence instead of conducting a manual valuation,this experimental study is a better and reliable option for assessing the integrity of the medical devices. 展开更多
关键词 integrity of the medical devices fuzzy-ANP.TOPSIS security assessment
下载PDF
Integrated Product Development in Rhinoplasty:A Case Study
18
作者 杨骁丽 刘凯 吴春茂 《Journal of Donghua University(English Edition)》 CAS 2023年第3期284-292,共9页
The 3D simulation in preoperative design for nasal plastic surgery was studied to help patients see the postoperative effects and reduce medical disputes.The study developed and clinically tested an innovative design ... The 3D simulation in preoperative design for nasal plastic surgery was studied to help patients see the postoperative effects and reduce medical disputes.The study developed and clinically tested an innovative design for surgical guides for nasal plastic surgery,which showed positive results in patient satisfaction and accuracy in achieving the preoperative simulated effect.The study also investigated the process of designing and producing nasal prostheses and how patient feedback could be obtained using third-party social media voting.Patient satisfaction information was collected and evaluated using the Likert scale,and the data statistical analysis was carried out with the SPSS19.0 software.More than 94.1% of the patients were satisfied with the postoperative results.The study provides a good reference case for the integration of knowledge and skills from the medicine,design,and engineering fields in the development of medical devices. 展开更多
关键词 integrated product development(IPD) RHINOPLASTY intraoperative navigation medical device
下载PDF
Integrated separation-electrochemical detection device based on wood column for online identification of enantiomer
19
作者 Junli Guo Yuanfei Xue +4 位作者 Chenxi Zhao Junjian Zhao Zhida Gao Ye Mei Yan-Yan Song 《Nano Research》 SCIE EI CSCD 2024年第3期1893-1901,共9页
Chiral chemicals have attracted significant interest in the pharmaceutical industry,yet the separation methods to get pure enantiomers from racemic mixture are still challenging.To date,the separation of enantiomers s... Chiral chemicals have attracted significant interest in the pharmaceutical industry,yet the separation methods to get pure enantiomers from racemic mixture are still challenging.To date,the separation of enantiomers still mainly depends on chromatography using high-cost chiral stationary phases.Herein,wood channels were used as the handheld integrated device,and enantiomer separation was simultaneously detected using an electrochemical detector.In this method,a chiral UIO-66(L-UIO-66)modified enantiomer separation zone and carbonized wood based online detection zone are integrated along a single wood column.Based on the in situ separation results from the chronoamperometry data,the wood device shows excellent separation ability for a wide range of electrochemically active enantiomers,including 3,4-dihydroxyphenylalanine,amino acids,ascorbic acid,carnitine,and penicillamine with high chirality purity.The unbiased molecular dynamic simulations indicate that the excellent chiral recognition and separation are attributed to the different barriers from the bound states to the dissociated state of the enantiomers in the homochiral microenvironment of the framework.This integrated enantiomer separation-electrochemical detection device provides a novel,easy,and low-cost platform for the separation of pure enantiomer from racemic mixture. 展开更多
关键词 wood column integrated separation-detection device ENANTIOSELECTIVITY online sensing free energy barrier
原文传递
Combination of Loosely and Compactly Coupled Integrations of CAD Tools and Its Applications In SAW Devices Design and Fabrication
20
作者 Peigang Li Jiaqin Zhang & Yuquan Hao(Institute 23 of the Second Academy of China National Aerospace Corporation P. O. Box 3923, N.37, Beijing 100854, China,) e-mail: zengxy9@hns.cjfh.ac.cn.(Received March 20, 1996) 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1996年第2期87-96,共10页
A combination of the loosely and compactly coupled integrations of CAD tools and its applications in the design and fabrication of surface acoustic wave (SAW) devices are proposed in this paper. Three core modules are... A combination of the loosely and compactly coupled integrations of CAD tools and its applications in the design and fabrication of surface acoustic wave (SAW) devices are proposed in this paper. Three core modules are developed as design and mask pattern verification module,database module, and device characteristics simulation module. All the operations are controlled under Microsoft Windows GUI interface. This leads to a reduced design and fabrication cycle, workload and cost. With the knowledge-based library for intelligent design and Lotus Notes database for distributed and networked engineering database management (EDM) and effective control of documents, a new enterprise-leveled, computer-integrated design and manufacturing system (CIDMS)can be established for monolithic and hybrid device design (not only confined to SAW device). 展开更多
关键词 SAW device simulation CAD tools integration DATABASE Mask pattern MS-Windows Knowledge base
下载PDF
上一页 1 2 97 下一页 到第
使用帮助 返回顶部