期刊文献+
共找到1,555篇文章
< 1 2 78 >
每页显示 20 50 100
The Resonance Suppression for Parallel Photovoltaic Grid-connected Inverters in Weak Grid 被引量:6
1
作者 Qiu-Xia Yang Kun Li +1 位作者 Cui-Mei Zhao Hu Wang 《International Journal of Automation and computing》 EI CSCD 2018年第6期716-727,共12页
Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation o... Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method. 展开更多
关键词 格子 光电 连接 平行 回声 参考电流 抑制方法 数学模型
原文传递
Performance Assessment of Islanding Detection for Mul-ti-inverter Grid-connected Photovoltaic Systems
2
作者 Xing Zhang Dong Xie 《Energy and Power Engineering》 2013年第4期1517-1520,共4页
Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature consideri... Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature considering DGS with only one inverter connected to the utility. With the big scale application of photovoltaic (PV) power systems, islanding detection technology of multi-inverter DGS has been paid more attention. This paper analyzes the performance of diverse islanding detection methods in multiple inverters grid-connected PV systems. Non-Detection Zones (NDZ) of multi-inverter systems in a load parameter space are used as analytical tool. The paper provides guidance for the islanding detection design in multiple grid-connected inverters. 展开更多
关键词 photovoltaic Power Systems ISLANDING DETECTION Multi-inverter Non-Detection ZONES
下载PDF
Non-Fullerene-Based Inverted Organic Photovoltaic Device with Long-Term Stability
3
作者 Do Hui Kim Febrian T.A.Wibowo +4 位作者 Dongchan Lee Narra V.Krishna Sujung Park Shinuk Cho Sung-Yeon Jang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2023年第3期214-221,共8页
In this work,we developed the PM6:Y6-based inverted structure organic photovoltaic(i-OPV)with improved power conversion efficiency(PCE)and long-term stability by resolving the origins of the performance deterioration.... In this work,we developed the PM6:Y6-based inverted structure organic photovoltaic(i-OPV)with improved power conversion efficiency(PCE)and long-term stability by resolving the origins of the performance deterioration.The deep defects between the metal oxide-based electron transport layer and bulk-heterojunction photoactive layer interface were responsible for suboptimal PCE and facilitated degradation of devices.While the density of deep traps is increased during the storage of i-OPV,the penetrative oxygen-containing defects additionally generated shallow traps below the band-edge of Y6,causing an additional loss in the open-circuit voltage.The suppression of interfacial defects by chemical modification effectively improved the PCE and long-term stability of i-OPV.The modified i-OPV(mi-OPV)achieved a PCE of 17.42%,which is the highest value among the reported PM6:Y6-based i-OPV devices.Moreover,long-term stability was significantly improved:~90%and~80%retention of its initial PCE after 1200 h of air storage and illumination,respectively. 展开更多
关键词 deep trap inverted structure long-term stability organic photovoltaic power conversion efficiency
下载PDF
New Approach of Multi-Cell Stacked Cell Inverter for Solar Photovoltaic System
4
作者 François Yonga Colince Welba +1 位作者 Abdouramani Dadjé Noël Djongyang 《Journal of Power and Energy Engineering》 2023年第1期1-17,共17页
In this paper, a new inverter topology dedicated to isolated or grid-connected PV systems is proposed. This inverter is based on the structures of a stacked multi-cell converter (SMC) and an H-bridge. This new topolog... In this paper, a new inverter topology dedicated to isolated or grid-connected PV systems is proposed. This inverter is based on the structures of a stacked multi-cell converter (SMC) and an H-bridge. This new topology has allowed the voltage stresses of the converter to be distributed among several switching cells. Secondly, divide the input voltage into several fractions to reduce the number of power semiconductors to be switched. In this contribution, the general topology of this micro-inverter has been described and the simulation tests developed to validate its operation have been presented. Finally, we discussed the simulation results, the efficiency of this topology and the feasibility of its use in a grid-connected photovoltaic production system. 展开更多
关键词 photovoltaic System MICRO-invertER Stacked Multi-Cell Converter (SMC) H-BRIDGE Pulse Width Modulation (PWM)
下载PDF
A Review of Novel Leakage Current Suppression Techniques for Transformerless Photovoltaic Inverters 被引量:32
5
作者 WU Weiyang GUO Xiaoqiang 《中国电机工程学报》 EI CSCD 北大核心 2012年第18期I0001-I0022,170,共22页
漏电流抑制是无变压器型光伏并网系统需要解决的关键问题之一。VDE-0126-1-1标准规定,漏电流高于300 mA时光伏并网系统必须在0.3 s内从电网中切除。为了解释漏电流的根源,建立系统共模电压数学模型,在此基础上分析漏电流产生的原因,探... 漏电流抑制是无变压器型光伏并网系统需要解决的关键问题之一。VDE-0126-1-1标准规定,漏电流高于300 mA时光伏并网系统必须在0.3 s内从电网中切除。为了解释漏电流的根源,建立系统共模电压数学模型,在此基础上分析漏电流产生的原因,探讨不同调制策略对漏电流的影响,然后介绍几种典型的、能够有效抑制漏电流的电路拓扑结构,并分析各种拓扑的工作原理和特点。最后对漏电流抑制技术方面的发展趋势做了展望。 展开更多
关键词 新型变压器 光伏系统 漏电流 逆变器 技术 综述 低成本 电网
下载PDF
H6 Non-isolated Full Bridge Grid-connected PV Inverters With Low Leakage Currents 被引量:29
6
作者 ZHANG Li SUN Kai +2 位作者 FENG Lanlan XING Yan XU Ming 《中国电机工程学报》 EI CSCD 北大核心 2012年第15期I0001-I0022,21,共22页
为满足非隔离光伏并网发电系统对共模漏电流的限制,提出一种六开关逆变器拓朴(H6拓扑)。所提出的H6拓扑在功率传输模态时,进网电流半个工频周期流过3支开关管,而另半个工频周期流过2支开关管,故相对于H5拓扑,降低了通态损耗,有... 为满足非隔离光伏并网发电系统对共模漏电流的限制,提出一种六开关逆变器拓朴(H6拓扑)。所提出的H6拓扑在功率传输模态时,进网电流半个工频周期流过3支开关管,而另半个工频周期流过2支开关管,故相对于H5拓扑,降低了通态损耗,有利于热应力均衡,且仍满足续流阶段光伏电池输出端与电网脱离的要求。详细分析拓扑的工作原理,并推论给出H6非隔离光伏并网逆变器的其它3种拓扑结构;比较分析了H5拓扑、Heric拓扑和H6拓扑的损耗和成本。通过1kW通用样机平台对比验证了上述3种拓扑的效率和共模特性。实验结果表明,H6拓扑的变换效率高于H5拓扑、但略低于Heric拓扑,共模特性优于Heric拓扑、但略劣于H5拓扑。 展开更多
关键词 全桥逆变器 并网逆变器 漏电流 共模电压 光伏发电
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:3
7
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Combined Active Islanding Detection Method for Grid-connected Photovoltaic System 被引量:2
8
作者 WEI Quan WANG Yifei +2 位作者 ZHU Jing YIN Xiaogang LIU Zhuang 《高压电器》 CAS CSCD 北大核心 2014年第10期37-42,共6页
Unintentional islanding phenomenon has been one of the most important problems of gridconnected photovoltaic inverters. To prevent this phenomenon, all kinds of anti-islanding methods have been discussed. This paper p... Unintentional islanding phenomenon has been one of the most important problems of gridconnected photovoltaic inverters. To prevent this phenomenon, all kinds of anti-islanding methods have been discussed. This paper presents a combined active islanding detection method, which consists of active frequency drift method and automatic phase-shift method. The traditional active anti-islanding methods of grid-connected PV inverters bear nondetection zone possibilities for certain paralleled RLC loads. The combined method shows islanding detection ability effectively, and it can eliminate nondetection zones even in the worst case conditions. Simulation in different load conditions is performed for verification. 展开更多
关键词 复合绝缘子 角度调节结构 绝缘操作杆 憎水性
下载PDF
Improved Voltage Control Strategy for Photovoltaic Grid-Connected System Based on DoubleLayer Coordination Control 被引量:3
9
作者 戚艳 贾宏杰 《Transactions of Tianjin University》 EI CAS 2012年第4期271-278,共8页
An improved automatic voltage coordination control strategy(AVCCS) based on automatic voltage control(AVC) and battery energy storage control(BESC) is proposed for photovoltaic grid-connected system(PVGS) to mitigate ... An improved automatic voltage coordination control strategy(AVCCS) based on automatic voltage control(AVC) and battery energy storage control(BESC) is proposed for photovoltaic grid-connected system(PVGS) to mitigate the voltage fluctuations caused by environmental disturbances.Only AVC is used when small environmental disturbances happen,while BESC is incorporated with AVC to restrain the voltage fluctuations when large disturbances happen.An adjustable parameter determining the allowed amplitudes of voltage fluctuations is introduced to realize the above switching process.A benchmark low voltage distribution system including PVGS is established by using the commercial software DIg SILENT.Simulation results show that the voltage under AVCCS satisfies the IEEE Standard 1547,and the installed battery capacity is also reduced.Meanwhile,the battery's service life is extended by avoiding frequent charges/discharges in the control process. 展开更多
关键词 协调控制策略 自动电压控制 低压配电系统 光伏并网 电压波动 IEEE标准 电池容量 环境干扰
下载PDF
Design of Grid-Connected Photovoltaic System
10
作者 Naseer Khan Muhammad Aamir +2 位作者 Faisal Mehmood Muhammad Aslam Muhammad Arif 《Journal of Power and Energy Engineering》 2017年第8期1-12,共12页
This paper presents a grid connected photovoltaic system (PV) with a proposed high voltage conversion ratio DC-DC converter which steps up the variable low input voltages of photovoltaic module to the required DC link... This paper presents a grid connected photovoltaic system (PV) with a proposed high voltage conversion ratio DC-DC converter which steps up the variable low input voltages of photovoltaic module to the required DC link voltage. This voltage is applied to an H-bridge inverter which converts DC voltage into AC voltage and a low pass filter is used to filter the output. By adjusting the duty ratio of switches in DC-DC converter, the magnitude of inverter’s output voltage is controlled. The frequency and phase synchronization are ensured by a feedback signal taken from the grid. In this way, inverter is synchronized and connected with the grid to meet the energy demand. The PV system has been designed and simulated. 展开更多
关键词 photovoltaic Systems (PV) High Voltage GAIN DC-DC CONVERTER PWM invertER SYNCHRONIZATION
下载PDF
Comparison between SiC- and Si-Based Inverters for Photovoltaic Power Generation Systems
11
作者 Yuji Ando Yasuhiro Shirahata +6 位作者 Takeo Oku Taisuke Matsumoto Yuya Ohishi Masashi Yasuda Akio Shimono Yoshikazu Takeda Mikio Murozono 《Journal of Power and Energy Engineering》 2017年第1期30-40,共11页
100-W class power storage systems were developed, which comprised spherical Si solar cells, a maximum power point tracking charge control-ler, a lithium-ion battery, and one of two different types of direct current (D... 100-W class power storage systems were developed, which comprised spherical Si solar cells, a maximum power point tracking charge control-ler, a lithium-ion battery, and one of two different types of direct current (DC)-alter- nating current (AC) converters. One inverter used SiC met-al-oxide-semicon-ductor field-effect transistors (MOSFETs) as switching devices while the other used Si MOSFETs. In these 100-W class inverters, the ON resistance was considered to have little influence on the efficiency. Nevertheless, the SiC-based inverter exhibited an approximately 3% higher DC-AC conversion efficiency than the Si-based inverter. Power loss analysis indicated that the higher efficiency resulted predominantly from lower switching and reverse recovery losses in the SiC MOSFETs compared with in the Si MOSFETs. 展开更多
关键词 Silicon CARBIDE Solar Cell invertER photovoltaic Device MAXIMUM Power Point Tracking LITHIUM-ION Battery
下载PDF
An Efficient Fuzzy Logic Fault Detection and Identification Method of Photovoltaic Inverters
12
作者 Mokhtar Aly Hegazy Rezk 《Computers, Materials & Continua》 SCIE EI 2021年第5期2283-2299,共17页
Fuzzy logic control(FLC)systems have found wide utilization in several industrial applications.This paper proposes a fuzzy logic-based fault detection and identification method for open-circuit switch fault in grid-ti... Fuzzy logic control(FLC)systems have found wide utilization in several industrial applications.This paper proposes a fuzzy logic-based fault detection and identification method for open-circuit switch fault in grid-tied photovoltaic(PV)inverters.Large installations and ambitious plans have been recently achieved for PV systems as clean and renewable power generation sources due to their improved environmental impacts and availability everywhere.Power converters represent the main parts for the grid integration of PV systems.However,PV power converters contain several power switches that construct their circuits.The power switches in PV systems are highly subjected to high stresses due to the continuously varying operating conditions.Moreover,the grid-tied systems represent nonlinear systems and the system model parameters are changing continuously.Consequently,the grid-tied PV systems have a nonlinear factor and the fault detection and identification(FDI)methods based on using mathematical models become more complex.The proposed fuzzy logic-based FDI(FL-FDI)method is based on employing the fuzzy logic concept for detecting and identifying the location of various switch faults.The proposed FL-FDI method is designed and extracted from the analysis and comparison of the various measured voltage/current components for the control purposes.Therefore,the proposed FL-FDI method does not require additional components or measurement circuits.Additionally,the proposed method can detect the faulty condition and also identify the location of the faulty switch for replacement and maintenance purposes.The proposed method can detect the faulty condition within only a single fundamental line period without the need for additional sensors and/or performing complex calculations or precise models.The proposed FL-FDI method is tested on the widely used T-type PV inverter system,wherein there are twelve different switches and the FDI process represents a challenging task.The results shows the superior and accurate performance of the proposed FL-FDI method. 展开更多
关键词 Fault detection and identification fuzzy logic T-type inverter photovoltaic(PV)
下载PDF
Research on Control Method of Inverters for Large-scale Grid Connected Photovoltaic Power System
13
作者 Zhuo Zhang Hongwei Li 《Energy and Power Engineering》 2013年第4期1503-1507,共5页
A grid-connected inverter controlling method to analyze dynamic process of large-scale and grid-connected photovoltaic power station is proposed. The reference values of control variables are composed of maximum power... A grid-connected inverter controlling method to analyze dynamic process of large-scale and grid-connected photovoltaic power station is proposed. The reference values of control variables are composed of maximum power which is the output of the photovoltaic array of the photovoltaic power plant, and power factor specified by dispatching, the control strategy of dynamic feedback linearization is adopted. Nonlinear decoupling controller is designed for realizing decoupling control of active and reactive power. The cascade PI regulation is proposed to avoid inaccurate parameter estimation which generates the system static error. Simulation is carried out based on the simplified power system with large-scale photovoltaic plant modelling, and the power factor, solar radiation strength, and bus fault are considered for the further research. It’s demonstrated that the parameter adjustment of PI controller is simple and convenient, dynamic response of system is transient, and the stability of the inverter control is verified. 展开更多
关键词 LARGE-SCALE photovoltaic grid-connected Dynamic Feedback LINEARIZATION Nonlinear DECOUPLING CASCADE Connection PI Control
下载PDF
Evaluation of the Performances of the First Grid-Connected Photovoltaic System in Sénégal
14
作者 P. W. Tavares H. D. Ndiath +3 位作者 M. Kane B. Mbow A. T. Niang I. Youm 《International Journal of Clean Coal and Energy》 2020年第1期1-14,共14页
This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugura... This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugurated on December 4th, 2012 by the governmental authorities of Senegal and Tenerife. This mini power plant of 3.15 kWc is a perfect example of the political will of the government which is to reduce the production cost of the electricity, with the diversification of the sources of production, and the greater use of the other sources such as the natural gas, the coal, the renewable energies. The evaluation of the performances of the installation is realized by using the indicators of efficiency and performance as the photovoltaic surface yield, the ratio of photovoltaic performance, the photovoltaic specific yield, and the losses of captures. The obtained results show that a big part of the energy shone during the period of observation was not able to be used further to circumstances such as the losses of conductivity, the heat losses or for example the defects on components. The analysis also shows that a large part of the produced energy is not injected because of the dilapidation of the network, the defects of landing but especially one disjunction sees frequently at the level of the point of injection. 展开更多
关键词 Analysis of the PERFORMANCES The photovoltaic SOLAR Energy grid-connected PV System Senegal
下载PDF
A Simulation Research on the Grid-Connected Control Technology of Single-Phase Inverters Based on MATLAB
15
作者 Jinjie Chen 《Journal of Electronic Research and Application》 2022年第4期7-12,共6页
This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-... This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results. 展开更多
关键词 Solar energy photovoltaic power generation grid-connected inverter circuit MATLAB simulation
下载PDF
Fault diagnosis and fault-tolerant control of photovoltaic micro-inverter 被引量:1
16
作者 李舟 彭涛 +2 位作者 张鹏飞 韩华 杨建 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第9期2284-2295,共12页
An observer-based fault diagnosis method and a fault tolerant control for open-switch fault and current sensor fault are proposed for interleaved flyback converters of a micro-inverter system. First, based on the topo... An observer-based fault diagnosis method and a fault tolerant control for open-switch fault and current sensor fault are proposed for interleaved flyback converters of a micro-inverter system. First, based on the topology of a grid-connected micro-inverter, a mathematical model of the flyback converters is established. Second, a state observer is applied to estimate the currents online and generate corresponding residuals. The fault is diagnosed by comparing the residuals with the thresholds. Finally, a fault-tolerant control that consists of a fault-tolerant topology for the faulty switch and a simple software redundancy control for the faulty current sensor, is proposed to achieve a fault-tolerant operation. The feasibility and effectiveness of the proposed method has been verified by simulation and experimental results. 展开更多
关键词 故障诊断方法 容错控制 逆变器 电流传感器 状态观测器 光伏 开关故障 拓扑结构
下载PDF
FCS-MPC Strategy for PV Grid-Connected Inverter Based on MLD Model
17
作者 Xiaojuan Lu Qingbo Zhang 《Energy Engineering》 EI 2021年第6期1729-1740,共12页
In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-conn... In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-connected inverter into the grid,and the output of the system can meet the grid-connected requirements more quickly and accurately,we exhibit an approach toward establishing a mixed logical dynamical(MLD)model where logic variables were introduced to switch dynamics of the single-phase photovoltaic inverters.Besides,based on the model,our recent efforts in studying the finite control set model predictive control(FCS-MPC)and devising the output current full state observer are exciting for several advantages,including effectively avoiding the problem of the mixed-integer quadratic programming(MIQP),lowering the THD value of the output current of the inverter circuit,improving the quality of the power that the inverter breaks into the grid,and realizing the current output and the grid voltage same frequency and phase to meet grid connection requirements.Finally,the effectiveness of the mentioned methods is verified by MATLAB/Simulink simulation. 展开更多
关键词 photovoltaic grid-connected inverter hybrid logic dynamic model finite control set model predictive control full state observer
下载PDF
Quasi-Z Source Inverter Control of PV Grid-Connected Based on Fuzzy PCI
18
作者 Tao Hou Chen-Yang Zhang Hong-Xia Niu 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第3期274-286,共13页
The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the powe... The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method. 展开更多
关键词 Frequency of harmonic distortion fuzzy proportional complex integral inductance-capacitance-inductance(LCL)filtering circuit photovoltaic grid-connection quasi-Z source inverter
下载PDF
An Improved Repetitive Control Strategy for LCL Grid-Connected Inverter
19
作者 Ning He Chenlu Song +1 位作者 Feng Gao Cheng Qian 《Journal of Beijing Institute of Technology》 EI CAS 2022年第4期391-400,共10页
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of... This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved. 展开更多
关键词 grid-connected inverter LCL filter harmonic suppression repetitive control
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
20
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter THREE-PHASE grid-connected inverter DECOUPLING Control
下载PDF
上一页 1 2 78 下一页 到第
使用帮助 返回顶部