The piezoelectric actuator has been widely used in precision instruments and precision control. However, hysteresis, nonlinearity and creep exist in the actuator, which limit actuator applications and affect accuracy....The piezoelectric actuator has been widely used in precision instruments and precision control. However, hysteresis, nonlinearity and creep exist in the actuator, which limit actuator applications and affect accuracy. This thesis introduces fuzzy control as the algorithm of a closed-loop control system to control the piezoelectric actuator. Fuzzy control can make this closed-looped system not only have high linearity, repeatability, accuracy and few overshoot, but isalso easily used.展开更多
The PID, fuzzy, self-organized fuzzy and self-organized fuzzy-PID controllers are adopted in the position control of single pneumatic muscle actuator. Experiments show that the self-organized fuzzy-PID is obviously ef...The PID, fuzzy, self-organized fuzzy and self-organized fuzzy-PID controllers are adopted in the position control of single pneumatic muscle actuator. Experiments show that the self-organized fuzzy-PID is obviously effective for the position control of single pneumatic muscle actuator, which can realize precision within 0.3 mm and withstand 18?N variable load plus about 36?N fixed load. It is relatively precise and robust.展开更多
The position control system of an electro-hydraulic actuator system (EHAS) is investigated in this paper. The EHAS is developed by taking into consideration the nonlinearities of the system: the friction and the in...The position control system of an electro-hydraulic actuator system (EHAS) is investigated in this paper. The EHAS is developed by taking into consideration the nonlinearities of the system: the friction and the internal leakage. A variable load that simulates a realistic load in robotic excavator is taken as the trajectory reference. A method of control strategy that is implemented by employing a fuzzy logic controller (FLC) whose parameters are optimized using particle swarm optimization (PSO) is proposed. The scaling factors of the fuzzy inference system are tuned to obtain the optimal values which yield the best system performance. The simulation results show that the FLC is able to track the trajectory reference accurately for a range of values of orifice opening. Beyond that range, the orifice opening may introduce chattering, which the FLC alone is not sufficient to overcome. The PSO optimized FLC can reduce the chattering significantly. This result justifies the implementation of the proposed method in position control of EHAS.展开更多
This paper deals with the problem of position and attitude tracking control for a rigid spacecraft.A fully actuated system(FAS)model for the six degree-of-freedom(6DOF)spacecraft motion is derived first from the state...This paper deals with the problem of position and attitude tracking control for a rigid spacecraft.A fully actuated system(FAS)model for the six degree-of-freedom(6DOF)spacecraft motion is derived first from the state-space model by variable elimination.Considering the uncertainties from external disturbance,unknown motion information,and uncertain inertia properties,an extended state observer(ESO)is designed to estimate the total disturbance.Then,a tracking controller based on FAS approach is designed,and this makes the closed-loop system a constant linear one with an arbitrarily assignable eigenstructure.The solution to the parameter matrices of the observer and controller is given subsequently.It is proved via the Lyapunov stability theory that the observer errors and tracking errors both converge into the neighborhood of the origin.Finally,numerical simulation demonstrates the effectiveness of the proposed controller.展开更多
文摘The piezoelectric actuator has been widely used in precision instruments and precision control. However, hysteresis, nonlinearity and creep exist in the actuator, which limit actuator applications and affect accuracy. This thesis introduces fuzzy control as the algorithm of a closed-loop control system to control the piezoelectric actuator. Fuzzy control can make this closed-looped system not only have high linearity, repeatability, accuracy and few overshoot, but isalso easily used.
文摘The PID, fuzzy, self-organized fuzzy and self-organized fuzzy-PID controllers are adopted in the position control of single pneumatic muscle actuator. Experiments show that the self-organized fuzzy-PID is obviously effective for the position control of single pneumatic muscle actuator, which can realize precision within 0.3 mm and withstand 18?N variable load plus about 36?N fixed load. It is relatively precise and robust.
文摘The position control system of an electro-hydraulic actuator system (EHAS) is investigated in this paper. The EHAS is developed by taking into consideration the nonlinearities of the system: the friction and the internal leakage. A variable load that simulates a realistic load in robotic excavator is taken as the trajectory reference. A method of control strategy that is implemented by employing a fuzzy logic controller (FLC) whose parameters are optimized using particle swarm optimization (PSO) is proposed. The scaling factors of the fuzzy inference system are tuned to obtain the optimal values which yield the best system performance. The simulation results show that the FLC is able to track the trajectory reference accurately for a range of values of orifice opening. Beyond that range, the orifice opening may introduce chattering, which the FLC alone is not sufficient to overcome. The PSO optimized FLC can reduce the chattering significantly. This result justifies the implementation of the proposed method in position control of EHAS.
基金This research was partially supported by the Science Center Program of the National Natural Science Foundation of China under Grant No.62188101the Major Program of the National Natural Science Foundation of China under Grant Nos.61690210 and 61690212the National Natural Science Foundation of China under Grant Nos.62103164 and 61703437.
文摘This paper deals with the problem of position and attitude tracking control for a rigid spacecraft.A fully actuated system(FAS)model for the six degree-of-freedom(6DOF)spacecraft motion is derived first from the state-space model by variable elimination.Considering the uncertainties from external disturbance,unknown motion information,and uncertain inertia properties,an extended state observer(ESO)is designed to estimate the total disturbance.Then,a tracking controller based on FAS approach is designed,and this makes the closed-loop system a constant linear one with an arbitrarily assignable eigenstructure.The solution to the parameter matrices of the observer and controller is given subsequently.It is proved via the Lyapunov stability theory that the observer errors and tracking errors both converge into the neighborhood of the origin.Finally,numerical simulation demonstrates the effectiveness of the proposed controller.
文摘为了提高电液伺服阀的静、动态性能,采用压电叠堆执行器作为电液伺服阀的前置驱动级,提出了一种新型高速精密压电型电液伺服阀.针对系统的非线性和不确定性,提出一种改进的自调整函数模糊控制方法,将系统偏差和偏差变化量在同一闭区间内分成若干等级完成归一模糊量化,将调整因子变为调整函数,并对比例因子进行自调整,从而避免迟滞非线性带来的系统振荡问题,提高模糊控制器精度.实验结果表明,新型压电型电液伺服阀的静态迟滞环<0.1%,分辨率优于0.03%,闭环控制时,幅频宽>700 Hz.