The steady-state vibration amplitude is an important performance indicator of high-frequency ultrasonic transducers for ultrasonically assisted manipulating,machining,and manufacturing.This work aimed to develop a cal...The steady-state vibration amplitude is an important performance indicator of high-frequency ultrasonic transducers for ultrasonically assisted manipulating,machining,and manufacturing.This work aimed to develop a calculation model for the steady-state vibration amplitude of a new type of dual-branch cascaded composite structure-based ultrasonic transducer that can be used in the packaging of microelectronic chips.First,the steady-state vibration amplitude of the piezoelectric vibrator of the transducer was derived from the piezoelectric equation.Second,the vibration transfer matrices of the tapered ultrasonic horns were obtained by combining the vibration equation,the continuous condition of the displacement,and the equilibrium condition of the force.Calculation models for the steady-state vibration amplitude of the two working ends of the transducer were then developed.A series of exciting trials were carried out to test the performance of the models.Comparison between the calculated and measured results for steady-state vibration amplitude showed that the maximum deviation was 0.0221μm,the minimum deviation was 0.0013μm,the average deviation was 0.0097μm,and the standard deviation was 0.0046μm.These values indicated good calculation accuracy,laying a good foundation for the practical application of the proposed transducer.展开更多
This paper presents a 591×438-DPI ultrasonic fingerprint sensor.The sensor is based on a piezoelectric micromachined ultrasonic transducer(PMUT)array that is bonded at wafer-level to complementary metal oxide sem...This paper presents a 591×438-DPI ultrasonic fingerprint sensor.The sensor is based on a piezoelectric micromachined ultrasonic transducer(PMUT)array that is bonded at wafer-level to complementary metal oxide semiconductor(CMOS)signal processing electronics to produce a pulse-echo ultrasonic imager on a chip.To meet the 500-DPI standard for consumer fingerprint sensors,the PMUT pitch was reduced by approximately a factor of two relative to an earlier design.We conducted a systematic design study of the individual PMUT and array to achieve this scaling while maintaining a high fill-factor.The resulting 110×56-PMUT array,composed of 30×43-μm^(2) rectangular PMUTs,achieved a 51.7% fill-factor,three times greater than that of the previous design.Together with the custom CMOS ASIC,the sensor achieves 2 mV kPa^(−1) sensitivity,15 kPa pressure output,75μm lateral resolution,and 150μm axial resolution in a 4.6 mm×3.2 mm image.To the best of our knowledge,we have demonstrated the first MEMS ultrasonic fingerprint sensor capable of imaging epidermis and sub-surface layer fingerprints.展开更多
The mechanical characterization of a 4×4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers(PMUTs)is pre-sented.The experimental campaign consists of three set of experi-mental tests,namely:t...The mechanical characterization of a 4×4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers(PMUTs)is pre-sented.The experimental campaign consists of three set of experi-mental tests,namely:topography measurements,small signal dynamic measurements,and vibrometry in the non-linear dynamic regime.The behavior of three different kinds of PMUT are reported.They differ according to the thermo-electrical treatment that has been applied to the piezoelectric material.The presence of the fabrication induced residual stresses is investigated and the treat-ment effect is evaluated in terms of the initial deflected configura-tion.The results reported in this paper represent an experimental mechanical investigation useful for the design of PMUT structures with advanced functionalities in the linear and non-linear regime.展开更多
基金This work was supported by the National Natural Science Foundation of China(Grant No.52175110)Author Hongjie Zhang has received research support from the National Natural Science Foundation of China.
文摘The steady-state vibration amplitude is an important performance indicator of high-frequency ultrasonic transducers for ultrasonically assisted manipulating,machining,and manufacturing.This work aimed to develop a calculation model for the steady-state vibration amplitude of a new type of dual-branch cascaded composite structure-based ultrasonic transducer that can be used in the packaging of microelectronic chips.First,the steady-state vibration amplitude of the piezoelectric vibrator of the transducer was derived from the piezoelectric equation.Second,the vibration transfer matrices of the tapered ultrasonic horns were obtained by combining the vibration equation,the continuous condition of the displacement,and the equilibrium condition of the force.Calculation models for the steady-state vibration amplitude of the two working ends of the transducer were then developed.A series of exciting trials were carried out to test the performance of the models.Comparison between the calculated and measured results for steady-state vibration amplitude showed that the maximum deviation was 0.0221μm,the minimum deviation was 0.0013μm,the average deviation was 0.0097μm,and the standard deviation was 0.0046μm.These values indicated good calculation accuracy,laying a good foundation for the practical application of the proposed transducer.
文摘This paper presents a 591×438-DPI ultrasonic fingerprint sensor.The sensor is based on a piezoelectric micromachined ultrasonic transducer(PMUT)array that is bonded at wafer-level to complementary metal oxide semiconductor(CMOS)signal processing electronics to produce a pulse-echo ultrasonic imager on a chip.To meet the 500-DPI standard for consumer fingerprint sensors,the PMUT pitch was reduced by approximately a factor of two relative to an earlier design.We conducted a systematic design study of the individual PMUT and array to achieve this scaling while maintaining a high fill-factor.The resulting 110×56-PMUT array,composed of 30×43-μm^(2) rectangular PMUTs,achieved a 51.7% fill-factor,three times greater than that of the previous design.Together with the custom CMOS ASIC,the sensor achieves 2 mV kPa^(−1) sensitivity,15 kPa pressure output,75μm lateral resolution,and 150μm axial resolution in a 4.6 mm×3.2 mm image.To the best of our knowledge,we have demonstrated the first MEMS ultrasonic fingerprint sensor capable of imaging epidermis and sub-surface layer fingerprints.
基金This work was supported by the ECSEL JOINT UNDERTAKING[826452].
文摘The mechanical characterization of a 4×4 air-coupled array of Piezoelectric Micromachined Ultrasonic Transducers(PMUTs)is pre-sented.The experimental campaign consists of three set of experi-mental tests,namely:topography measurements,small signal dynamic measurements,and vibrometry in the non-linear dynamic regime.The behavior of three different kinds of PMUT are reported.They differ according to the thermo-electrical treatment that has been applied to the piezoelectric material.The presence of the fabrication induced residual stresses is investigated and the treat-ment effect is evaluated in terms of the initial deflected configura-tion.The results reported in this paper represent an experimental mechanical investigation useful for the design of PMUT structures with advanced functionalities in the linear and non-linear regime.