The control system of voltage source converter HVDC (VSC-HVDC) is complex and its fault tolerance ability is not sufficient, and correct rate of line protection device is not high. A novel pilot protection for VSC-HVD...The control system of voltage source converter HVDC (VSC-HVDC) is complex and its fault tolerance ability is not sufficient, and correct rate of line protection device is not high. A novel pilot protection for VSC-HVDC transmission lines based on correlation analysis is proposed in this paper. In the principle, external fault is equivalent to a positive capacitance model, so the correlation coefficient of the current and voltage derivative is 1;while the internal fault is equivalent to a negative capacitance model, so the correlation coefficient of the current and voltage derivative is -1. Internal faults and external faults can be distinguished by judging the correlation coefficient. Theoretical analysis and PSCAD simulation experiments show that the new principle, which is simple, not affected by transition resistance, control type and line distributed capacitance current, can identify internal faults and external faults reliably and rapidly, having certain practical value.展开更多
Current phase comparison based pilot protection had been generally utilized as primary protection of the transmission lines in China from the 1950's to the 1980' s, Comentional phase comparison pilot protection has ...Current phase comparison based pilot protection had been generally utilized as primary protection of the transmission lines in China from the 1950's to the 1980' s, Comentional phase comparison pilot protection has a long phase comparison time, which results in a longer fault-clearing time. This paper proposes a new current phase comparison, pilot protection scheme that is based on non-power frequency fauh eun'ent component. The phase of the fourth harmonic eun'ent of each end of the protected line has heen abstracted hy utilizing complex wavelet transformation and then compared in order to determine whether the inner fauh occurs or not. This way can greatly deerease fauh-elearing time and improve performances of this pilot protection when fault occurs under the heavy-load current and asymmetrical operation eonditions, Many EMTP simulations have verified the proposed scheme's correctness and effectiveness.展开更多
As the penetration of wind power into power grids increases,higher demands are made on the stability and protection of power systems.Unlike traditional synchronous generators,wind turbines are different on the short-c...As the penetration of wind power into power grids increases,higher demands are made on the stability and protection of power systems.Unlike traditional synchronous generators,wind turbines are different on the short-circuit and impedance characteristics,thus some problems exist in pilot protections of transmission lines connecting wind farms.When a single-phase fault occurs on a transmission line,the phase selector based on current-difference sudden-change may mistake the single-phase fault for a phase-to-phase fault.This paper studies the impedance characteristics of an asynchronous wind generator,and analyzes the behavior of a fault phase selector under different conditions.Then,the paper explains that inequality between positive and negative branch coefficients is the cause for the mal-operation of the fault phase selector.Finally,some simulations are done in MATLAB to validate analysis results.展开更多
A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types,which makes this protection scheme more complicated.A new pilot protection schem...A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types,which makes this protection scheme more complicated.A new pilot protection scheme for a three-terminal hybrid DC transmission system applying energy functions is proposed.The energy function for LCC is applied to MMC to derive the energy level of the hybrid system.Furthermore,an improved Hausdorff distance(IHD)algorithm is proposed to detect the difference in energy levels between the normal and fault states.An abrupt change in energy level is characterized by IHD change rate.Time points at which the IHD change rate exceeds the threshold at converter stations are applied to determine the fault line and to estimate the fault section.The proposed protection scheme is then verified by a simulation model of the Wudongde±800 kV three-terminal hybrid UHVDC transmission project.The appropriate sampling frequency is selected for a real-time calculation,and the threshold is selected considering the effect of noise.Results show the proposed scheme can identify and trip fault lines quickly and effectively,even for a 600Ωgrounding fault.Other waveshape similarity algorithms are compared and analyzed.Compared with existing protection schemes,the proposed scheme transmits less data to improve communication speed and reliability.展开更多
Inverter-based distributed generations(IBDGs)are the main approach to utilizing clean energy in distribution networks(DNs).Compared with synchronous source,fault response of IBDG is very different.As a result,in DNs w...Inverter-based distributed generations(IBDGs)are the main approach to utilizing clean energy in distribution networks(DNs).Compared with synchronous source,fault response of IBDG is very different.As a result,in DNs with high penetration of IBDGs,legacy protection schemes will no longer be applicable.In this paper,an energy-based directional pilot protection scheme suitabie for DNs with IBDGs is proposed.This scheme considers the large range of phase angle caused by IBDG integration and uses improved energy polarity criterion to determine fault direction.In addition,magnitude of energy is used to distinguish between faults and load switching to overcome maloperation of directional pilot protection caused by internal unmeasured load switching.The proposed scheme first uses local measured information to determine fault direction sign and then exchanges the direction sign with the remote terminal.This scheme does not require high-bandwidth communication and strict data synchronization,so it can be implemented at a low cost.Finally,simulation studies verify effectiveness of the proposed scheme.展开更多
The hybrid cascaded high-voltage direct current(HVDC)transmission system has various operation modes,and some operation modes have sharply increasing requirements for protection rapidity,while the traditional pilot di...The hybrid cascaded high-voltage direct current(HVDC)transmission system has various operation modes,and some operation modes have sharply increasing requirements for protection rapidity,while the traditional pilot differential protection(PDP)has poor rapidity,and even refuses to operate when faults occur on the DC line.Therefore,a novel pilot protection scheme based on traveling wave characteristics is proposed.First,the adaptability of the traditional PDP applied in engineering is analyzed for different operation modes.Then,the expressions of the forward traveling wave(FTW)and backward traveling wave(BTW)on the rectifier side and the inverter side are derived for different fault locations.From the theoretical derivation,the difference between the BTW and FTW on the rectifier side is less than zero,and the same is true on the inverter side.However,in the event of an external fault of DC line,the difference between the BTW and FTW at nearfault terminal protection installation point is greater than zero.Therefore,by summing over the product of the difference between BTW and FTW of the rectifier side and that of the inverter side,the fault identification criterion is constructed.The simulation results show that the proposed pilot protection scheme can quickly and reliably identify the short-circuit faults of DC line in different operation modes.展开更多
The spread and innovative application of MOOC in China has rapidly triggered a profound revolution in the curriculum construction and teaching reform of universities,promoting significant results in teaching and talen...The spread and innovative application of MOOC in China has rapidly triggered a profound revolution in the curriculum construction and teaching reform of universities,promoting significant results in teaching and talent cultivation.Based on the practice of“MOOC teaching pilot colleges”carried out by the China University Computer Education MOOC Consortium in some universities in China,this paper proposes the overall plan of MOOC teaching pilot colleges construction through the analysis of typical cases,pointing out the purpose and significance of the reform of the pilot college and giving the relevant concepts and requirements.This thesis focuses on the reform of teaching methods,assessment methods,grade calculation and credit recognition,and stress assessment,emphasizing the need for a three-dimensional process management of teachers,students,and college teaching administrators,and the need to focus on institutional development to provide protection.MOOC teaching pilot colleges should reform and innovate in practice,and they should keep solving the problems they encounter and deepen the reform,so as to provide useful experiences and reference practices for the landing and high-quality development of MOOC teaching in more universities.展开更多
文摘The control system of voltage source converter HVDC (VSC-HVDC) is complex and its fault tolerance ability is not sufficient, and correct rate of line protection device is not high. A novel pilot protection for VSC-HVDC transmission lines based on correlation analysis is proposed in this paper. In the principle, external fault is equivalent to a positive capacitance model, so the correlation coefficient of the current and voltage derivative is 1;while the internal fault is equivalent to a negative capacitance model, so the correlation coefficient of the current and voltage derivative is -1. Internal faults and external faults can be distinguished by judging the correlation coefficient. Theoretical analysis and PSCAD simulation experiments show that the new principle, which is simple, not affected by transition resistance, control type and line distributed capacitance current, can identify internal faults and external faults reliably and rapidly, having certain practical value.
基金Sponsored by the Power Electrical Science and Technology Foundation of XJ Group and the Shanghai University Foundation for Excellent Young Teacher.
文摘Current phase comparison based pilot protection had been generally utilized as primary protection of the transmission lines in China from the 1950's to the 1980' s, Comentional phase comparison pilot protection has a long phase comparison time, which results in a longer fault-clearing time. This paper proposes a new current phase comparison, pilot protection scheme that is based on non-power frequency fauh eun'ent component. The phase of the fourth harmonic eun'ent of each end of the protected line has heen abstracted hy utilizing complex wavelet transformation and then compared in order to determine whether the inner fauh occurs or not. This way can greatly deerease fauh-elearing time and improve performances of this pilot protection when fault occurs under the heavy-load current and asymmetrical operation eonditions, Many EMTP simulations have verified the proposed scheme's correctness and effectiveness.
基金supported by National Basic Research Program of China(No.2009CB219704)National Natural Science Foundation of China (No. 50977061)National Natural Science Foundation of Tianjin City (No. 11JCYBJC07600)
文摘As the penetration of wind power into power grids increases,higher demands are made on the stability and protection of power systems.Unlike traditional synchronous generators,wind turbines are different on the short-circuit and impedance characteristics,thus some problems exist in pilot protections of transmission lines connecting wind farms.When a single-phase fault occurs on a transmission line,the phase selector based on current-difference sudden-change may mistake the single-phase fault for a phase-to-phase fault.This paper studies the impedance characteristics of an asynchronous wind generator,and analyzes the behavior of a fault phase selector under different conditions.Then,the paper explains that inequality between positive and negative branch coefficients is the cause for the mal-operation of the fault phase selector.Finally,some simulations are done in MATLAB to validate analysis results.
基金supported by the Science and Technology Project of China Southern Power Co.,Ltd.(CGYKJXM20180508).
文摘A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types,which makes this protection scheme more complicated.A new pilot protection scheme for a three-terminal hybrid DC transmission system applying energy functions is proposed.The energy function for LCC is applied to MMC to derive the energy level of the hybrid system.Furthermore,an improved Hausdorff distance(IHD)algorithm is proposed to detect the difference in energy levels between the normal and fault states.An abrupt change in energy level is characterized by IHD change rate.Time points at which the IHD change rate exceeds the threshold at converter stations are applied to determine the fault line and to estimate the fault section.The proposed protection scheme is then verified by a simulation model of the Wudongde±800 kV three-terminal hybrid UHVDC transmission project.The appropriate sampling frequency is selected for a real-time calculation,and the threshold is selected considering the effect of noise.Results show the proposed scheme can identify and trip fault lines quickly and effectively,even for a 600Ωgrounding fault.Other waveshape similarity algorithms are compared and analyzed.Compared with existing protection schemes,the proposed scheme transmits less data to improve communication speed and reliability.
基金supported in part by The Spring City Industry Leadership Talent Support Program(2018014)in part by Science and Technology Project of State Grid Corporation of China(2020A-048)。
文摘Inverter-based distributed generations(IBDGs)are the main approach to utilizing clean energy in distribution networks(DNs).Compared with synchronous source,fault response of IBDG is very different.As a result,in DNs with high penetration of IBDGs,legacy protection schemes will no longer be applicable.In this paper,an energy-based directional pilot protection scheme suitabie for DNs with IBDGs is proposed.This scheme considers the large range of phase angle caused by IBDG integration and uses improved energy polarity criterion to determine fault direction.In addition,magnitude of energy is used to distinguish between faults and load switching to overcome maloperation of directional pilot protection caused by internal unmeasured load switching.The proposed scheme first uses local measured information to determine fault direction sign and then exchanges the direction sign with the remote terminal.This scheme does not require high-bandwidth communication and strict data synchronization,so it can be implemented at a low cost.Finally,simulation studies verify effectiveness of the proposed scheme.
基金supported in part by the National Natural Science Foundation of China(No.51977183)。
文摘The hybrid cascaded high-voltage direct current(HVDC)transmission system has various operation modes,and some operation modes have sharply increasing requirements for protection rapidity,while the traditional pilot differential protection(PDP)has poor rapidity,and even refuses to operate when faults occur on the DC line.Therefore,a novel pilot protection scheme based on traveling wave characteristics is proposed.First,the adaptability of the traditional PDP applied in engineering is analyzed for different operation modes.Then,the expressions of the forward traveling wave(FTW)and backward traveling wave(BTW)on the rectifier side and the inverter side are derived for different fault locations.From the theoretical derivation,the difference between the BTW and FTW on the rectifier side is less than zero,and the same is true on the inverter side.However,in the event of an external fault of DC line,the difference between the BTW and FTW at nearfault terminal protection installation point is greater than zero.Therefore,by summing over the product of the difference between BTW and FTW of the rectifier side and that of the inverter side,the fault identification criterion is constructed.The simulation results show that the proposed pilot protection scheme can quickly and reliably identify the short-circuit faults of DC line in different operation modes.
基金This work was supported by the Exploration and Application of Teaching Mode Based on Mu Class in Higher Education Project Entrusted by the Higher Education Department of the Ministry of Education in 2020“Online Open Course Construction and Online Teaching Model Research under the New Normal after the Epidemic”(Grant No.3)2020 Shandong Province Undergraduate Teaching Reform Research and Cultivation Project“Research and Practice of Mixed Teaching Mode Under the Construction of MOOC Teaching Pilot College”(Grant No.26),“Top-notch Multidisciplinary Interdisciplinary Integration Research and Practice of Innovative Talents Training Mode-Taking the Construction of Future Technology College as the Leading”(Grant No.96),and“Innovative Research and Practice of New Engineering Agile Education Model Facing Sustainable Competitiveness”(Grant No.46)+3 种基金Shandong Province Undergraduate Teaching Reform in 2020“New Engineering Specialty Construction Research”(Grant No.15)2019 Harbin Institute of Technology(Weihai)Education and Teaching Reform Research Project“Research and Practice on the Large-Class Mixed Teaching Model of Computer Major Core Courses Based on MOOC”(Grant No.BKJY201904)“Research and Practice on the Through Teaching Mode of Embedded System Courses-History to Reality,Theory to Practice,Online to Offline”(Grant No.BKJY201905)“University Computer”course(Grant No.BKQN201912).
文摘The spread and innovative application of MOOC in China has rapidly triggered a profound revolution in the curriculum construction and teaching reform of universities,promoting significant results in teaching and talent cultivation.Based on the practice of“MOOC teaching pilot colleges”carried out by the China University Computer Education MOOC Consortium in some universities in China,this paper proposes the overall plan of MOOC teaching pilot colleges construction through the analysis of typical cases,pointing out the purpose and significance of the reform of the pilot college and giving the relevant concepts and requirements.This thesis focuses on the reform of teaching methods,assessment methods,grade calculation and credit recognition,and stress assessment,emphasizing the need for a three-dimensional process management of teachers,students,and college teaching administrators,and the need to focus on institutional development to provide protection.MOOC teaching pilot colleges should reform and innovate in practice,and they should keep solving the problems they encounter and deepen the reform,so as to provide useful experiences and reference practices for the landing and high-quality development of MOOC teaching in more universities.