A test platform is established as per the practical working condition ofelevating platform fire truck. The influences of pipes and load on dynamic characteristics ofload-sensing system are studied by series of step re...A test platform is established as per the practical working condition ofelevating platform fire truck. The influences of pipes and load on dynamic characteristics ofload-sensing system are studied by series of step response experiments. Experimental results showthat the feedback pipe makes the most important influence on the dynamic response speed ofload-sensing system. Its internal diameter should be optimized for given length of pipe. On theother hand, the stability of load-sensing pump is improved as the length of input pipe increases ina certain range. The influence of input pipe on the dynamic response speed is caused mainly by thepressure-wave travel time in the input pipe.展开更多
The loss of metal in a pipe due to corrosion usually results in localized thinned areas with various depths and an irregular shape on its surface. In this paper, a number of numerical models of pipes with different si...The loss of metal in a pipe due to corrosion usually results in localized thinned areas with various depths and an irregular shape on its surface. In this paper, a number of numerical models of pipes with different size defects are established. The limit loads of these pipes are researched using the nonlinear finite element method. The effect of defect parameters of the local wall-thinning pipes on the limit load is discussed. The results show that limit loads decrease obviously when the depths and lengths of the defect increase. However, when the defect length reaches a certain value, the effect of defect length on limit loads is not significant. These results are compared with the results of the method of API 579. When the defect length is adequately small, the results of FEM are in good agreement with the ones of APl 579, but when the defect depth and length is adequately large, the API 579 is not suitable.展开更多
Recently a research team at Ohio University,USA,conducted a unique full-scale feld load test to simulate the aeration pipe installations at a copper extraction mine operated in Chile.The overliner material taken from ...Recently a research team at Ohio University,USA,conducted a unique full-scale feld load test to simulate the aeration pipe installations at a copper extraction mine operated in Chile.The overliner material taken from the mine was used in recreating the in situ conditions.Electric heaters were utilized to raise the temperature inside each pipe to simulate the essential element of the copper extraction process.The maximum vertical deflection reached by the test pipes was close to 20%,when the simulated heap pile height was 80 m.The plastic pipes and the overliner material were also tested in the laboratory.Based on the results,the maximum heap pile fll depth was recommended for the aeration system.The results indicated that the vertical deflection was the primary performance index for the aeration pipes installed in heap piles at mines.Lastly,the pipe made of polypropylene resin was super.展开更多
基金This project is supported by National Natural Science Foundation of China(No.59875076).
文摘A test platform is established as per the practical working condition ofelevating platform fire truck. The influences of pipes and load on dynamic characteristics ofload-sensing system are studied by series of step response experiments. Experimental results showthat the feedback pipe makes the most important influence on the dynamic response speed ofload-sensing system. Its internal diameter should be optimized for given length of pipe. On theother hand, the stability of load-sensing pump is improved as the length of input pipe increases ina certain range. The influence of input pipe on the dynamic response speed is caused mainly by thepressure-wave travel time in the input pipe.
基金supported by the National High Technol-ogy Research and Development Program of China(2007AA04Z404)Natural Science Basic Research Plan in Shaanxi Province of China (SJ08A17)the Technical Innovation Foundation of NWPU(2008KJ02019)
文摘The loss of metal in a pipe due to corrosion usually results in localized thinned areas with various depths and an irregular shape on its surface. In this paper, a number of numerical models of pipes with different size defects are established. The limit loads of these pipes are researched using the nonlinear finite element method. The effect of defect parameters of the local wall-thinning pipes on the limit load is discussed. The results show that limit loads decrease obviously when the depths and lengths of the defect increase. However, when the defect length reaches a certain value, the effect of defect length on limit loads is not significant. These results are compared with the results of the method of API 579. When the defect length is adequately small, the results of FEM are in good agreement with the ones of APl 579, but when the defect depth and length is adequately large, the API 579 is not suitable.
文摘Recently a research team at Ohio University,USA,conducted a unique full-scale feld load test to simulate the aeration pipe installations at a copper extraction mine operated in Chile.The overliner material taken from the mine was used in recreating the in situ conditions.Electric heaters were utilized to raise the temperature inside each pipe to simulate the essential element of the copper extraction process.The maximum vertical deflection reached by the test pipes was close to 20%,when the simulated heap pile height was 80 m.The plastic pipes and the overliner material were also tested in the laboratory.Based on the results,the maximum heap pile fll depth was recommended for the aeration system.The results indicated that the vertical deflection was the primary performance index for the aeration pipes installed in heap piles at mines.Lastly,the pipe made of polypropylene resin was super.