期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Pressure-Dependent Models in Ship Piping Systems 被引量:1
1
作者 Daniel Molina Pérez Lemuel C.Ramos-Arzola Amadelis Quesada Torres 《Journal of Marine Science and Application》 CSCD 2020年第2期266-274,共9页
This paper aims to evaluate the feasibility of pressure-dependent models in the design of ship piping systems.For this purpose,a complex ship piping system is designed to operate in firefighting and bilge services thr... This paper aims to evaluate the feasibility of pressure-dependent models in the design of ship piping systems.For this purpose,a complex ship piping system is designed to operate in firefighting and bilge services through jet pumps.The system is solved as pressure-dependent model by the piping system analysis software EPANET and by a mathematical approach involving a piping network model.This results in a functional system that guarantees the recommendable ranges of hydraulic state variables(flow and pressure)and compliance with the rules of ship classification societies.Through this research,the suitability and viability of pressure-dependent models in the simulation of a ship piping system are proven. 展开更多
关键词 Pressure-dependent models Ship piping systems Bilge systems Firefighting systems piping network models
下载PDF
On-line measurement of temperature and water vapor in CH_4 /air premixed flame using near-infrared diode laser 被引量:4
2
作者 陶波 叶锡生 +2 位作者 胡志云 张立荣 刘晶儒 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第11期1098-1101,共4页
We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for t... We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for temperature measurements.The measurements are performed on a flat burner based on scannedwavelength direct absorption spectroscopy using two adjacent water lines at 7153.75 and 7154.35 cm 1.Real-time results are acquired using a data acquisition card with a Labview data processing program.The standard uncertainties of the temperature and water concentration measurements are 2.3% and 5.1%,respectively. 展开更多
关键词 Data acquisition Data handling Infrared lasers Semiconductor lasers Temperature measurement Uncertainty analysis Water absorption Water piping systems Water supply Water vapor
原文传递
上一页 1 下一页 到第