The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the h...The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the hybrid ventilation system applied in bidirectional excavation tunnels with a long inclined shaft,this study has established a full-scale computational fluid dynamics model based on field tests,the Poly-Hexcore method,and the sliding mesh technique.The distribution of wind speed,temperature field,and CO in the tunnel are taken as indices to compare the ventilation efficiency of three ventilation systems(duct,duct-ventilation shaft,duct–ventilated shaft-axial fan).The results show that the hybrid ventilation scheme based on duct-ventilation shaft–axial fan performs the best among the three ventilation systems.Compared to the duct,the wind speed and cooling rate in the tunnel are enhanced by 7.5%–30.6%and 14.1%–17.7%,respectively,for the duct-vent shaft-axial fan condition,and the volume fractions of CO are reduced by 26.9%–73.9%.This contributes to the effective design of combined ventilation for bidirectional excavation tunnels with an inclined shaft,ultimately improving the air quality within the tunnel.展开更多
The smoke spreading law of urban transportation tunnels with multiple shafts under natural ventilation is studied.A full-scale burning experiment is conducted in an actual tunnel.The study shows that smoke temperature...The smoke spreading law of urban transportation tunnels with multiple shafts under natural ventilation is studied.A full-scale burning experiment is conducted in an actual tunnel.The study shows that smoke temperatures below the tunnel ceiling reduce rapidly along the longitudinal towards the tunnel exits. A noticeable temperature stratification is observed near the fire source.Most fire smoke is exhausted out of the shafts while the number of the smoke shafts in the downstream is more than that in the upstream.Large eddy simulation LES based on computational fluid dynamics CFD is carried out using the fire dynamics simulator FDS software with parallel processing in which the grid size of the fire-domain is set to be 0.083 m.The simulation results of temperatures under the ceiling the smoke fronts and the shafts'smoke exhaust or air supply agree reasonably with the experimental data. Further simulations indicate that the decreasing ambient temperature or shaft spacing might reduce smoke temperatures under the tunnel ceiling and increase mass flow rates out of the shafts.This study provides technical scientific evidence and supports for the design and construction of such kinds of tunnels.展开更多
基金Project(N2022G031)supported by the Science and Technology Research and Development Program Project of China RailwayProjects(2022-Key-23,2021-Special-01A)supported by the Science and Technology Research and Development Program Project of China Railway Group LimitedProject(52308419)supported by the National Natural Science Foundation of China。
文摘The breakage and bending of ducts result in a difficulty to cope with ventilation issues in bidirectional excavation tunnels with a long inclined shaft using a single ventilation method based on ducts.To discuss the hybrid ventilation system applied in bidirectional excavation tunnels with a long inclined shaft,this study has established a full-scale computational fluid dynamics model based on field tests,the Poly-Hexcore method,and the sliding mesh technique.The distribution of wind speed,temperature field,and CO in the tunnel are taken as indices to compare the ventilation efficiency of three ventilation systems(duct,duct-ventilation shaft,duct–ventilated shaft-axial fan).The results show that the hybrid ventilation scheme based on duct-ventilation shaft–axial fan performs the best among the three ventilation systems.Compared to the duct,the wind speed and cooling rate in the tunnel are enhanced by 7.5%–30.6%and 14.1%–17.7%,respectively,for the duct-vent shaft-axial fan condition,and the volume fractions of CO are reduced by 26.9%–73.9%.This contributes to the effective design of combined ventilation for bidirectional excavation tunnels with an inclined shaft,ultimately improving the air quality within the tunnel.
基金The National Natural Science Foundation of China(No.51178217)the Natural Science Foundation of Jiangsu Province(No.BK2011804)
文摘The smoke spreading law of urban transportation tunnels with multiple shafts under natural ventilation is studied.A full-scale burning experiment is conducted in an actual tunnel.The study shows that smoke temperatures below the tunnel ceiling reduce rapidly along the longitudinal towards the tunnel exits. A noticeable temperature stratification is observed near the fire source.Most fire smoke is exhausted out of the shafts while the number of the smoke shafts in the downstream is more than that in the upstream.Large eddy simulation LES based on computational fluid dynamics CFD is carried out using the fire dynamics simulator FDS software with parallel processing in which the grid size of the fire-domain is set to be 0.083 m.The simulation results of temperatures under the ceiling the smoke fronts and the shafts'smoke exhaust or air supply agree reasonably with the experimental data. Further simulations indicate that the decreasing ambient temperature or shaft spacing might reduce smoke temperatures under the tunnel ceiling and increase mass flow rates out of the shafts.This study provides technical scientific evidence and supports for the design and construction of such kinds of tunnels.