期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Investigation of the Resistance and Inductance of Planar Wire Array Z-Pinch at the Qiangguang Accelerator
1
作者 王亮平 吴坚 +4 位作者 郭宁 韩娟娟 李沫 李岩 邱爱慈 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第9期842-846,共5页
The resistance and inductance of a wire array during an implosion are very important parameters of interest to:researchers. A variety of inductances and resistances directly affect the kinetic energy and resistance h... The resistance and inductance of a wire array during an implosion are very important parameters of interest to:researchers. A variety of inductances and resistances directly affect the kinetic energy and resistance heat energy coupled from a pulsed-power generator. In this paper, the inductance and resistance of a planar wire array during the Z-pinch process are analyzed. The inductance is calculated from the data obtained by a time-resolved soft X-ray framed camera, while the resistance is calculated through the voltage and the current of the wire array load combined with the variety of the inductance. The results show that the resistance of the load increases with the development of the implosion, and reaches its maximum at 0.29 ± 0.16Ω near the pinched time. 展开更多
关键词 planar wire array INDUCTANCE RESISTANCE Z-PINCH Qiangguang generator
下载PDF
Two dynamics modes in planar wire array Z pinch implosion
2
作者 盛亮 王亮平 +3 位作者 吴坚 李阳 彭博栋 张美 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第5期315-318,共4页
Two dynamics modes, named short ablation mode and long ablation mode, are observed in implosion experiments of planar wire array Z pinch on 'QiangGuang-I' facility utilizing an optical streak camera. The long ablati... Two dynamics modes, named short ablation mode and long ablation mode, are observed in implosion experiments of planar wire array Z pinch on 'QiangGuang-I' facility utilizing an optical streak camera. The long ablation mode has a lagged trajectory compared with the short ablation mode. For shot 10035 in a short ablation mode, the initial time of K-shell radiation is consistent with the interaction time for ablation plasma arriving at the centre of wire array, while for shot 10038 in long ablation mode, the initial time of K-shell radiation is about 10 ns earlier. In the two modes, the partial ablation plasma could traverse the wire array plane and then collide in the centre to form a dense plasma column with a diameter of 2.2 mm for shot 10035 and 1.5 mm for shot 10038. 展开更多
关键词 ablation mode imploding dynamics planar wire array Z pinch
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部