A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achie...A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun.展开更多
To understand the formation process of vacuum gap in coaxial microsecond conduction time plasma opening switch(POS),we have made measurements of the line-integrated plasma density during switch operation using a time-...To understand the formation process of vacuum gap in coaxial microsecond conduction time plasma opening switch(POS),we have made measurements of the line-integrated plasma density during switch operation using a time-resolved sensitive He-Ne interferometer.The conduction current and conduction time in experiments are about 120 kA and 1 s,respectively.As a result,more than 85%of conduction current has been transferred to an inductive load with rise time of 130 ns.The radial dependence of the density is measured by changing the radial location of the line-of-sight for shots with the same nominal POS parameters.During the conduction phase,the line-integrated plasma density in POS increases at all radial locations over the gun-only case by further ionization of material injected from the guns.The current conduction is observed to cause a radial redistribution of the switch plasma.A vacuum gap forms rapidly in the plasma at 5.5 mm from the center conductor,which is consistent with the location where magnetic pressure is the largest,allowing current to be transferred from the POS to the load.展开更多
文摘A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun.
基金supported by the National Natural Science Foundation of China(Grant No.51177155)
文摘To understand the formation process of vacuum gap in coaxial microsecond conduction time plasma opening switch(POS),we have made measurements of the line-integrated plasma density during switch operation using a time-resolved sensitive He-Ne interferometer.The conduction current and conduction time in experiments are about 120 kA and 1 s,respectively.As a result,more than 85%of conduction current has been transferred to an inductive load with rise time of 130 ns.The radial dependence of the density is measured by changing the radial location of the line-of-sight for shots with the same nominal POS parameters.During the conduction phase,the line-integrated plasma density in POS increases at all radial locations over the gun-only case by further ionization of material injected from the guns.The current conduction is observed to cause a radial redistribution of the switch plasma.A vacuum gap forms rapidly in the plasma at 5.5 mm from the center conductor,which is consistent with the location where magnetic pressure is the largest,allowing current to be transferred from the POS to the load.