期刊文献+
共找到67,290篇文章
< 1 2 250 >
每页显示 20 50 100
Study of plasma parameters of coaxial plasma source using triple Langmuir probe and Faraday cup diagnostics
1
作者 Sunil KANCHI Rohit SHUKLA Archana SHARMA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期94-100,共7页
Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In... Coaxial plasma guns are a type of plasma source that produces plasma which propagates radially and axially controlled by the shape of the ground electrode, which has attracted much interest in several applications. In this work, a 120° opening angle of CPG nozzle is used as a plasma gun configuration that operates at the energy of 150 J. The ionization of polyethylene insulator between the electrodes of the gun produces a cloud of hydrogen and carbon plasma.The triple Langmuir probe and Faraday cup are used to measure plasma density and plasma temperature. These methods are used to measure the on-axis and off-axis plasma divergence of the coaxial plasma gun. The peak values of ion densities measured at a distance of 25 mm on-axis from the plasma gun are(1.6±0.5)×10^(19)m^(-3)and(2.8±0.6)×10^(19)m^(-3)for hydrogen and carbon plasma respectively and the peak temperature is 3.02±0.5 eV. The mean propagation velocity of plasma is calculated using the transit times of plasma at different distances from the plasma gun and is found to be 4.54±0.25 cm/μs and 1.81±0.18 cm/μs for hydrogen and carbon plasma respectively. The Debye radius is obtained from the measured experimental data that satisfies the thin sheath approximation. The shot-to-shot stability of plasma parameters facilitates the use of plasma guns in laboratory experiments. These types of plasma sources can be used in many applications like plasma opening switches, plasma devices, and as plasma sources. 展开更多
关键词 coaxial plasma source triple Langmuir probe Faraday cup plasma density plasma temperature
下载PDF
Effects of external parameters on plasma characteristics and uniformity in a dual cylindrical inductively coupled plasma
2
作者 Pengyu WANG Siyu XING +5 位作者 Daoman HAN Yuru ZHANG Yong LI Cheng ZHOU Fei GAO Younian WANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期63-74,共12页
The dual cylindrical inductively coupled plasma source,compared to the conventional structure of inductively coupled plasma source,can significantly improve the uniformity of plasma.It has an enhanced potential for ap... The dual cylindrical inductively coupled plasma source,compared to the conventional structure of inductively coupled plasma source,can significantly improve the uniformity of plasma.It has an enhanced potential for application in processes,such as etching and ashing.A uniform plasma can be obtained by allowing the remote plasma from the upper chamber modulate the main plasma generated in the lower chamber.In this study,a fluid model was employed to investigate a dual cylindrical inductively coupled Ar/O_(2)discharge.The effects of external parameters on electron density,electron temperature,O atomic density,and plasma uniformity in the main chamber were studied,and the reasons were analyzed.The results of this study show that remote power can control the plasma uniformity and increase the plasma density in the main chamber.As the remote power increased,plasma uniformity improved initially and then deteriorated.The main power affected the plasma density at the edge of the main chamber and can modulate the plasma density in the main chamber.The gas pressure affected both the uniformity and density of the plasma.As the gas pressure increased,the plasma uniformity deteriorated,but the free radical density improved. 展开更多
关键词 dual inductively coupled plasma remote plasma plasma uniformity fluid model
下载PDF
Different bactericidal abilities of plasma-activated saline with various reactive species prepared by surface plasma-activated air and plasma jet combinations
3
作者 贾怡康 李甜会 +5 位作者 张瑞 赵鹏瑜 王子丰 陈旻 郭莉 刘定新 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第1期50-61,共12页
Plasma-activated water(PAW),as an extended form of cold atmospheric-pressure plasma,greatly expands the application of plasma-based technology.The biological effects of PAW are closely related to the aqueous reactive ... Plasma-activated water(PAW),as an extended form of cold atmospheric-pressure plasma,greatly expands the application of plasma-based technology.The biological effects of PAW are closely related to the aqueous reactive species,which can be regulated by the activation process.In this study,surface plasma-activated air(SAA)and a He+O_(2)plasma jet(Jet)were parallelly combined(the SAA+Jet combination)or sequentially combined(the SAA→Jet combination and the Jet→SAA combination)to prepare plasma-activated saline(PAS).The PAS activated by the combinations exhibited stronger bactericidal effects than that activated by the SAA or the Jet alone.The concentrations of H_(2)O_(2)and NO_(2)^(-)were higher in the PAS activated by the Jet→SAA combination,while ONOO^(-)concentrations were close in the three kinds of PAS and^(1)O_(2)concentrations were higher in the PAS activated by the SAA+Jet combination.The analysis of scavengers also demonstrated that H_(2)O_(2),^(1)O_(2),and ONOO^(-)in the PAS activated by the SAA+Jet combination,and^(1)O_(2)in the PAS activated by the Jet→SAA combination played critical roles in bactericidal effects.Further,the effective placement time of the three PAS varied,and the PAS activated by the Jet→SAA combination could also inactivate 2.6-log_(10)of MRSA cells after placement for more than 60 min.The regulation of reactive species in plasma-activated water via different combinations of plasma devices could improve the directional application of plasma-activated water in the biomedical field. 展开更多
关键词 plasma-activated water surface plasma-activated air plasma jet bactericidal effect reactive species
下载PDF
New Sorbent for Bilirubin Removal from Human Plasma: Albumin Immobilized Microporous Membranous PTFE Capillaries 被引量:3
4
作者 Lei ZHANG Gu JIN 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第11期1495-1498,共4页
In this study, we developed a tailored capillary sorbent for bilirubin removal. For immobilized bioligand, capillaries were grafted with epoxy groups using RIGP. The HSA immobilized capillaries has a high affinity ads... In this study, we developed a tailored capillary sorbent for bilirubin removal. For immobilized bioligand, capillaries were grafted with epoxy groups using RIGP. The HSA immobilized capillaries has a high affinity adsorption capacity (71.2 mg bilirubin/g polymer) and a shorter adsorption equilibrium time (about 60 min). 展开更多
关键词 bilirubin removal radiation grafting PTFE capillaries human serum albumin.
下载PDF
Higher plasma bilirubin predicts veno-occlusive disease in early childhood undergoing hematopoietic stem cell transplantation with cyclosporine 被引量:1
5
作者 Kwi Suk Kim Aree Moon +4 位作者 Hyoung Jin Kang Hee Young Shin Young Hee Choi Hyang Sook Kim Sang Geon Kim 《World Journal of Transplantation》 2016年第2期403-410,共8页
AIM: To analyze the association between plasma bilirubin levels and veno-occlusive disease(VOD) in non-adult patients undergoing hematopoietic stem cell transplantation(HSCT) during cyclosporine therapy.METHODS: A tot... AIM: To analyze the association between plasma bilirubin levels and veno-occlusive disease(VOD) in non-adult patients undergoing hematopoietic stem cell transplantation(HSCT) during cyclosporine therapy.METHODS: A total of 123 patients taking cyclosporinewere evaluated using an electronic medical system at the Seoul National University Children's Hospital from the years 2004 through 2011. Patients were grouped by age and analyzed for incidence and type of adverse drug reactions(ADRs) including VOD. RESULTS: The HSCT patients were divided into three age groups: G#1 ≥ 18; 9 ≤ G#2 ≤ 17; and G#3 ≤ 8 years of age). The majority of transplant donor types were cord blood transplantations. Most prevalent ADRs represented acute graft-vs-host disease(a GVHD) and VOD. Although the incidences of a GVHD did not vary among the groups, the higher frequency ratios of VOD in G#3 suggested that an age of 8 or younger is a risk factor for developing VOD in HSCT patients. After cyclosporine therapy, the trough plasma concentrations of cyclosporine were lower in G#3 than in G#1, indicative of its increased clearance. Moreover, in G#3 only, a maximal total bilirubin level(BILmax) of ≥ 1.4 mg/d L correlated with VOD incidence after cyclosporine therapy. CONCLUSION: HSCT patients 8 years of age or younger are more at risk for developing VOD, diagnosed as hyperbilirubinemia, tender hepatomegaly, and ascites/weight gain after cyclosporine therapy, which may be represented by a criterion of plasma BILmax being ≥ 1.4 mg/d L, suggestive of more sensitive VOD indication in this age group. 展开更多
关键词 HEMATOPOIETIC stem cell TRANSPLANTATION Veno-occlusive disease CYCLOSPORINE ADVERSE drug reaction Total bilirubin
下载PDF
The multi-peak point phenomenon of broadband microwave reflection caused by inhomogeneous plasma
6
作者 杨敏 齐凯旋 +5 位作者 杨玖文 贾飒 刘浩岩 陈燕扬 李瑾 李小平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期1-11,共11页
During spacecraft re-entry,the challenge of measuring plasma sheath parameters directly contributes to difficulties in addressing communication blackout.In this work,we have discovered a phenomenon of multiple peaks i... During spacecraft re-entry,the challenge of measuring plasma sheath parameters directly contributes to difficulties in addressing communication blackout.In this work,we have discovered a phenomenon of multiple peaks in reflection data caused by the inhomogeneous plasma.Simulation results show that the multi-peak points fade away as the characteristic frequency is approached,resembling a series of gradually decreasing peaks.The positions and quantities of these points are positively correlated with electron density,yet they show no relation to collision frequency.This phenomenon is of significant reference value for future studies on the spatial distribution of plasmas,particularly for using microwave reflection signals in diagnosing the plasma sheath. 展开更多
关键词 plasma sheath microwave reflection inhomogeneous plasma
下载PDF
Final results of the first phase of the PROTO-SPHERA experiment: obtainment of the full current stable screw pinch and first evidences of the jet + torus combined plasma configuration
7
作者 Paolo MICOZZI Franco ALLADIO +21 位作者 Alessandro MANCUSO Vincenzo ZANZA Gerarda APRUZZESE Francesca BOMBARDA Luca BONCAGNI Paolo BURATTI Francesco FILIPPI Giuseppe GALATOLA TEKA Francesco GIAMMANCO Edmondo GIOVANNOZZI Andrea GROSSO Matteo IAFRATI Alessandro LAMPASI Violeta LAZIC Simone MAGAGNINO Simone MANNORI Paolo MARSILI Valerio PIERGOTTI Giuliano ROCCHI Alessandro SIBIO Benedetto TILIA Onofrio TUDISCO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期31-43,共13页
In astrophysics, the boundary conditions for plasma phenomena are provided by nature and the astronomer faces the problem of understanding them from a variety of observations [Hester J J et al 1996 Astrophys. J. 456 2... In astrophysics, the boundary conditions for plasma phenomena are provided by nature and the astronomer faces the problem of understanding them from a variety of observations [Hester J J et al 1996 Astrophys. J. 456 225], on the other hand, in laboratory plasma experiments the electromagnetic boundary conditions become a major problem in the set-up of the machine that produces the plasma, an issue that has to be investigated step by step and to be modified and adapted with great patience, in particular in the case of an innovative plasma confinement experiment. The PROTO-SPHERA machine [Alladio F et al 2006 Nucl. Fusion 46 S613] is a magnetic confinement experiment, that emulates in the laboratory the jet + torus plasma configurations often observed in astrophysics: an inner magnetized jet of plasma centered on the(approximate) axis of symmetry and surrounded by a magnetized plasma torus orthogonal to this jet. The PROTO-SPHERA plasma is simply connected, i.e., no metal current conducting rod is linked to the plasma torus, while instead it is the inner magnetized plasma jet(in the following always called the plasma centerpost) that is linked to the torus. It is mandatory that no spurious plasma current path modifies the optimal shape of the plasma centerpost. Moreover, as the plasma torus is produced and sustained, in absence of any applied inductive electric field, by the inner plasma centerpost through magnetic reconnections [Taylor J B and Turner M F 1989 Nucl.Fusion 29 219], it is required as well that spurious current paths do not surround the torus on its outboard, in order not to lower the efficiency of the magnetic reconnections that maintain the plasma torus at the expense of the plasma centerpost. Boundary conditions have been corrected,up to the point that the first sustainment in steady state has been achieved for the combined plasma. 展开更多
关键词 laboratory plasmas magnetic confinement astrophysical plasmas
下载PDF
Experimental confirmation of the linear relation between plasma current and external vertical magnetic field in EXL-50 spherical torus energetic electron plasmas
8
作者 董力立 王明远 +9 位作者 刘文军 石跃江 董家齐 郭栋 孙恬恬 顾翔 宋显明 袁保山 彭元凯 the ENN Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期32-36,共5页
A three-fluid equilibrium plasma with bulk plasma and energetic electrons has been observed on the Xuanlong-50(EXL-50) spherical torus, where the energetic electrons play a crucial role in sustaining the plasma curren... A three-fluid equilibrium plasma with bulk plasma and energetic electrons has been observed on the Xuanlong-50(EXL-50) spherical torus, where the energetic electrons play a crucial role in sustaining the plasma current and pressure. In this study, the equilibrium of a multi-fluid plasma was investigated by analyzing the relationship between the external vertical magnetic field(B_(V)),plasma current(I_(p)), the poloidal ratio(β_(p)) and the Shafranov formula. Remarkably, our research demonstrates some validity of the Shafranov formula in the presence of multi-fluid plasma in EXL-50 spherical torus. This finding holds significant importance for future reactors as it allows for differentiation between alpha particles and background plasma. The study of multi-fluid plasma provides a significant reference value for the equilibrium reconstruction of burning plasma involving alpha particles. 展开更多
关键词 plasma equilibrium Shafranov formula multi-fluid plasma
下载PDF
Effect of matrix thermal properties on laser-induced plasma
9
作者 Yuheng Shan An Li +4 位作者 Xinyu Zhang Wen Yi Ying Zhang Xiaodong Liu Ruibin Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第10期331-336,共6页
The matrix thermal properties have an important impact on laser-induced plasma,as the thermal effect dominates the interaction between ns-pulsed laser and matter,especially in metals.We used a series of pure metals an... The matrix thermal properties have an important impact on laser-induced plasma,as the thermal effect dominates the interaction between ns-pulsed laser and matter,especially in metals.We used a series of pure metals and aluminum alloys to measure plasma temperature and electron density through laser-induced breakdown spectroscopy,in order to investigate the effect of matrix thermal properties on laser-induced plasma.In pure metals,a significant negative linear correlation was observed between the matrix thermal storage coefficient and plasma temperature,while a weak correlation was observed with electron density.The results indicate that metals with low thermal conductivity or specific heat capacity require less laser energy for thermal diffusion or melting and evaporation,resulting in higher ablation rates and higher plasma temperatures.However,considering ionization energy,thermal effects may be a secondary factor affecting electron density.The experiment of aluminum alloy further confirms the influence of thermal conductivity on plasma temperature and its mechanism explanation. 展开更多
关键词 laser-induced plasma thermal properties matrix effect thermal storage coefficient plasma temperature
下载PDF
Customized modulation on plasma uniformity by non-uniform magnetic field in capacitively coupled plasma
10
作者 王森 张权治 +2 位作者 马方方 Maksudbek YUSUPOV 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期79-87,共9页
A two-dimensional fluid model based on COMSOL Multiphysics is developed to investigate the modulation of static magnetic field on plasma homogeneity in a capacitively coupled plasma(CCP)chamber. To generate a static m... A two-dimensional fluid model based on COMSOL Multiphysics is developed to investigate the modulation of static magnetic field on plasma homogeneity in a capacitively coupled plasma(CCP)chamber. To generate a static magnetic field, direct current is applied to a circular coil located at the top of the chamber. By adjusting the magnetic field's configuration, which is done by altering the coil current and position, both the plasma uniformity and density can be significantly modulated. In the absence of the magnetic field, the plasma density exhibits an inhomogeneous distribution characterized by higher values at the plasma edge and lower values at the center. The introduction of a magnetic field generated by coils results in a significant increase in electron density near the coils. Furthermore, an increase in the sets of coils improves the uniformity of the plasma. By flexibly adjusting the positions of the coils and the applied current,a substantial enhancement in overall uniformity can be achieved. These findings demonstrate the feasibility of using this method for achieving uniform plasma densities in industrial applications. 展开更多
关键词 COMSOL capacitively coupled plasma plasma uniformity magnetic field
下载PDF
Tunable energy spectrum betatron x-ray sources in a plasma wakefield
11
作者 奚传易 寿寅任 +4 位作者 韩立琦 阿卜杜伍普尔·阿布力米提 刘晓丹 赵研英 余金清 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期344-350,共7页
X-ray sources with tunable energy spectra have a wide range of applications in different scenarios due to their different penetration depths.However,existing x-ray sources face difficulties in terms of energy regulati... X-ray sources with tunable energy spectra have a wide range of applications in different scenarios due to their different penetration depths.However,existing x-ray sources face difficulties in terms of energy regulation.In this paper,we present a scheme for tuning the energy spectrum of a betatron x-ray generated from a relativistic electron bunch oscillating in a plasma wakefield.The center energy of the x-ray source can be tuned from several keV to several hundred keV by changing the plasma density,thereby extending the control range by an order of magnitude.At different central energies,the brightness of the betatron radiation is in the range of 3.7×10^(22)to 5.5×10^(22)photons/(0.1%BW·s·mm^(2)·mrad^(2))and the photon divergence angle is about 2 mrad.This high-brightness,energy-controlled betatron source could pave the way to a wide range of applications requiring photons of specific energy,such as phase-contrast imaging in medicine,non-destructive testing and material analysis in industry,and imaging in nuclear physics. 展开更多
关键词 betatron plasma physics X-RAY plasma wakefield acceleration(PWFA)
下载PDF
Edge effect during microwave plasma chemical vapor deposition diamond-film:Multiphysics simulation and experimental verification
12
作者 Zhiliang Yang Kang An +7 位作者 Yuchen Liu Zhijian Guo Siwu Shao Jinlong Liu Junjun Wei Liangxian Chen Lishu Wu Chengming Li 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第10期2287-2299,共13页
This study focused on the investigation of the edge effect of diamond films deposited by microwave plasma chemical vapor de-position.Substrate bulge height△h is a factor that affects the edge effect,and it was used t... This study focused on the investigation of the edge effect of diamond films deposited by microwave plasma chemical vapor de-position.Substrate bulge height△h is a factor that affects the edge effect,and it was used to simulate plasma and guide the diamond-film deposition experiments.Finite-element software COMSOL Multiphysics was used to construct a multiphysics(electromagnetic,plasma,and fluid heat transfer fields)coupling model based on electron collision reaction.Raman spectroscopy and scanning electron microscopy were performed to characterize the experimental growth and validate the model.The simulation results reflected the experimental trends observed.Plasma discharge at the edge of the substrate accelerated due to the increase in△h(△h=0-3 mm),and the values of electron density(n_(c)),molar concentration of H(C_(H)),and molar concentration of CH_(3)(C_(CH_(3)))doubled at the edge(for the special concave sample with△h=−1 mm,the active chemical groups exhibited a decreased molar concentration at the edge of the substrate).At=0-3 mm,a high diamond growth rate and a large diamond grain size were observed at the edge of the substrate,and their values increased with.The uniformity of film thickness decreased with.The Raman spectra of all samples revealed the first-order characteristic peak of dia-mond near 1332 cm^(−1).When△h=−1 mm,tensile stress occurred in all regions of the film.When△h=1-3 mm,all areas in the film ex-hibited compressive stress. 展开更多
关键词 microwave plasma chemical vapor deposition edge discharge plasma diamond film
下载PDF
A research on the effect of plasma spectrum collection device on LIBS spectral intensity
13
作者 林晓梅 董艳杰 +5 位作者 林京君 黄玉涛 杨江飞 岳星宇 张倬嘉 段鑫杨 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期121-128,共8页
Only a small amount of spectral information is collected because the collection solid angle of the optical fiber probe and lens is very limited when collecting spectral information.To overcome this limitation,this stu... Only a small amount of spectral information is collected because the collection solid angle of the optical fiber probe and lens is very limited when collecting spectral information.To overcome this limitation,this study presents a novel method for acquiring plasma spectral information from various spatial directions.A parabolic-shaped plasma spectral collection device(PSCD)is employed to effectively collect more spectral information into the spectrometer,thereby enhancing the overall spectral intensity.The research objects in this study were soil samples containing different concentrations of heavy metals Pb,Cr,and Cd.The results indicate that the PSCD significantly enhances the spectral signal,with an enhancement rate of up to 45%.Moreover,the signal-to-noise ratio also increases by as much as 36%.Simultaneously,when compared to the absence of a device,it is found that there is no significant variation in plasma temperature when the PSCD is utilized.This observation eliminates the impact of the spatial effect caused by the PSCD on the spectral intensity.Consequently,a concentrationspectral intensity relationship curve is established under the PSCD.The results revealed that the linear fitting R^(2)for Pb,Cr,and Cd increased by 0.011,0.001,and 0.054,respectively.Additionally,the limit of detection(LOD)decreased by 0.361 ppm,0.901 ppm,and 0.602 ppm,respectively.These findings indicate that the spectral enhancement rate elevates with the increase in heavy metal concentration.Hence,the PSCD can effectively enhance the spectral intensity and reduce the detection limit of heavy metals in soil. 展开更多
关键词 LIBS plasma spectrum collection device spectral enhancement plasma temperature limit of detection
下载PDF
Wave field structure and power coupling features of blue-core helicon plasma driven by various antenna geometries and frequencies
14
作者 王超 刘佳 +3 位作者 苌磊 卢凌峰 张世杰 周帆涛 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期480-487,共8页
This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagat... This paper deals with wave propagation and power coupling in blue-core helicon plasma driven by various antennas and frequencies.It is found that compared to non-blue-core mode,for blue-core mode,the wave can propagate in the core region,and it decays sharply outside the core.The power absorption is lower and steeper in radius for blue-core mode.Regarding the effects of antenna geometry for blue-core mode,it shows that half helix antenna yields the strongest wave field and power absorption,while loop antenna yields the lowest.Moreover,near axis,for antennas with m=+1,the wave field increases with axial distance.In the core region,the wave number approaches to a saturation value at much lower frequency for non-blue-core mode compared to blue-core mode.The total loading resistance is much lower for blue-core mode.These findings are valuable to understanding the physics of blue-core helicon discharge and optimizing the experimental performance of blue-core helicon plasma sources for applications such as space propulsion and material treatment. 展开更多
关键词 helicon plasma helicon wave helicon discharge radio frequency plasma source
下载PDF
Effect of coil and chamber structure on plasma radial uniformity in radio frequency inductively coupled plasma
15
作者 赵洋 周晓华 +2 位作者 高升荣 宋莎莎 赵玉真 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期58-66,共9页
Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial m... Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial manufacturing.This study utilized a two-dimensional self-consistent fluid model to investigate how different coil configurations and chamber aspect ratios affect the radial uniformity of plasma in radio frequency ICP.The findings indicate that optimizing the radial spacing of the coil enhances plasma uniformity but with a reduction in electron density.Furthermore,optimizing the coil within the ICP reactor,using the interior point method in the Interior Point Optimizer significantly enhances plasma uniformity,elevating it from 56%to 96%within the range of the model sizes.Additionally,when the chamber aspect ratio k changes from 2.8 to 4.7,the plasma distribution changes from a center-high to a saddleshaped distribution.Moreover,the plasma uniformity becomes worse.Finally,adjusting process parameters,such as increasing source power and gas pressure,can enhance plasma uniformity.These findings contribute to optimizing the etching process by improving plasma radial uniformity. 展开更多
关键词 inductively coupled plasma fluid simulation optimized coil chamber aspect ratio plasma uniformity
下载PDF
Integrated design and performance optimization of three-electrode sliding discharge plasma power supply
16
作者 Borui ZHENG Linwu WANG +4 位作者 Jianbo ZHANG Shaojie QI Yuhong CHEN Haodong LIU Dongliang BIAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第11期152-161,共10页
The three-electrode sliding dielectric barrier discharge(TES-DBD) plasma actuator significantly enhances the ionization rate and momentum exchange between charged particles and neutral particles by incorporating a par... The three-electrode sliding dielectric barrier discharge(TES-DBD) plasma actuator significantly enhances the ionization rate and momentum exchange between charged particles and neutral particles by incorporating a parallel DC electrode into the standard DBD design. This design improves the body force and induced jet velocity while allowing flexible control of the induced jet angle, overcoming the limitations of discharge extension and uncontrollable direction in traditional DBD plasma actuators. An integrated plasma power supply has been designed specifically for TES-DBD plasma actuators, streamlining the power supply management. The methodology involves designing the circuit topology for the TES-DBD power supply, followed by simulating and validating its operating principles using Multisim software. The operational performance of the power supply is evaluated through a comprehensive analysis of its electrical,thermal, and aerodynamic properties specific to TES-DBD plasma actuation. 展开更多
关键词 plasma flow control dielectric barrier discharge three-electrode sliding discharge plasma power supply
下载PDF
Influence of bias voltage and oxygen addition on the discharge aspects of a diffuse argon plume in an atmospheric pressure plasma jet
17
作者 Pengying JIA Guoxin HAN +6 位作者 Xiupin DONG Kaiyue WU Junxia RAN Xuexia PANG Xuexue ZHANG Jiacun WU Xuechen LI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期75-81,共7页
A remote plasma,also referred to as a plasma plume(diffuse or filamentary),is normally formed downstream of an atmospheric pressure plasma jet.In this study,a diffuse plume is formed by increasing the bias voltage(U_(... A remote plasma,also referred to as a plasma plume(diffuse or filamentary),is normally formed downstream of an atmospheric pressure plasma jet.In this study,a diffuse plume is formed by increasing the bias voltage(U_(b))applied to the downstream electrode of an argon plasma jet excited by a negatively pulsed voltage.The results indicate that the plume is filamentary when U_(b)is low,which transits to the diffuse plume with increasing U_(b).The discharge initiated at the rising edge of the pulsed voltage is attributed to the diffuse plume,while that at the falling edge contributes to the filament in the plume.For the diffuse plume,the discharge intensity decreases with the increasing oxygen content(C_o).Fast photography reveals that the diffuse plume results from a negative streamer,which has a dark region near the nozzle with C_o=0%.However,the dark region is absent with C_o=0.5%.From the optical emission spectrum,the electron density,electron excitation temperature,gas temperature,and oxygen atom concentration are investigated. 展开更多
关键词 atmospheric pressure plasma jet diffuse plasma plume optical emission spectrum
下载PDF
Plasma density enhancement in radio-frequency hollow electrode discharge
18
作者 贺柳良 何锋 欧阳吉庭 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期44-51,共8页
The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results s... The plasma density enhancement outside hollow electrodes in capacitively coupled radio-frequency(RF) discharges is investigated by a two-dimensional(2D) particle-in-cell/Monte-Carlo collision(PIC/MCC) model. Results show that plasma exists inside the cavity when the sheath inside the hollow electrode hole is fully collapsed, which is an essential condition for the plasma density enhancement outside hollow electrodes. In addition, the existence of the electron density peak at the orifice is generated via the hollow cathode effect(HCE), which plays an important role in the density enhancement. It is also found that the radial width of bulk plasma at the orifice affects the magnitude of the density enhancement, and narrow radial plasma bulk width at the orifice is not beneficial to obtain high-density plasma outside hollow electrodes.Higher electron density at the orifice, combined with larger radial plasma bulk width at the orifice,causes higher electron density outside hollow electrodes. The results also imply that the HCE strength inside the cavity cannot be determined by the magnitude of the electron density outside hollow electrodes. 展开更多
关键词 RF capacitively coupled plasma sources plasma density enhancement hollow cathodeeffect hollow electrode
下载PDF
Percentile analysis of plasma total bilirubin—How different will the rate of phototherapy for jaundice of neonates be by different standards?
19
作者 Yoshiro Nagao Hiroshi Watanabe Syun-ichiro Yokota 《Open Journal of Pediatrics》 2012年第2期133-137,共5页
Phototherapy of a jaundiced neonate is usually started when bilirubin exceeds a threshold in the standard. There are several standards used in the developed countries even though the guideline of American Academy of P... Phototherapy of a jaundiced neonate is usually started when bilirubin exceeds a threshold in the standard. There are several standards used in the developed countries even though the guideline of American Academy of Pediatrics is considered to be a global standard. Although the purpose of phototherapy is the prevention of kernicterus, nowadays the prevalence of kernicterus in otherwise healthy term neonates in the developed countries is rare. Meanwhile several potential adverse effects of phototherapy have been reported. In the present study we tried to estimate how different the rate of phototherapy for the jaundice of neonates at lower risk of kernicterus would be by different standards. For this purpose, we utilized the records of plasma total bilirubin (TB) values of 1893 healthy neonates of 38 weeks and more which were measured on day 6 for the percentile analysis. However, this database did not include the TB values of the neonates who received phototherapy by day 6. Then the database was corrected with an assumption that TB on day 6 would have been normally distributed if no phototherapy had been performed. The mean and the standard deviation (SD) of corrected database were 11.29 mg/dl (193 μmol/l) and 3.63 mg/dl (62 μmol/l), respectively. Using a standard distribution with these mean and SD, the percents of TB values which exceed 18.0, 19.0, 20.0 and 21.0 mg/dl on day 6 were estimated 3.22%, 1.70%, 0.82% and 0.35%, respectively. Results of the present report would help to estimate the relative rate of phototherapy that is performed for the neonates who are term and otherwise healthy by different standards. 展开更多
关键词 Neonatal JAUNDICE bilirubin PHOTOTHERAPY KERNICTERUS
下载PDF
Spark plasma sintering of tungsten-based WTaVCr refractory high entropy alloys for nuclear fusion applications
20
作者 Yongchul Yoo Xiang Zhang +4 位作者 Fei Wang Xin Chen Xing-Zhong Li Michael Nastasi Bai Cui 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CSCD 2024年第1期146-154,共9页
W-based WTaVCr refractory high entropy alloys (RHEA) may be novel and promising candidate materials for plasma facing components in the first wall and diverter in fusion reactors. This alloy has been developed by a po... W-based WTaVCr refractory high entropy alloys (RHEA) may be novel and promising candidate materials for plasma facing components in the first wall and diverter in fusion reactors. This alloy has been developed by a powder metallurgy process combining mechanical alloying and spark plasma sintering (SPS). The SPSed samples contained two phases, in which the matrix is RHEA with a body-centered cubic structure, while the oxide phase was most likely Ta2VO6through a combined analysis of X-ray diffraction (XRD),energy-dispersive spectroscopy (EDS), and selected area electron diffraction (SAED). The higher oxygen affinity of Ta and V may explain the preferential formation of their oxide phases based on thermodynamic calculations. Electron backscatter diffraction (EBSD) revealed an average grain size of 6.2μm. WTaVCr RHEA showed a peak compressive strength of 2997 MPa at room temperature and much higher micro-and nano-hardness than W and other W-based RHEAs in the literature. Their high Rockwell hardness can be retained to at least 1000°C. 展开更多
关键词 refractory high entropy alloy plasma-facing material fusion reactor spark plasma sintering
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部