To measure the pulsed neutron of a pulsed fission source, an organic scintillation fiber (OSF) detector with separation structure has been designed. The proposed detector employs UV optical fibers as the light guide...To measure the pulsed neutron of a pulsed fission source, an organic scintillation fiber (OSF) detector with separation structure has been designed. The proposed detector employs UV optical fibers as the light guide, and the sensitive region of the detector is composed of a linear array of OSFs, which are individually connected to the optical fibers. The other end of the light guide is coupled to a photomultiplier tube. The key properties of the device including the energy response, time response, neutron sensitivity, and radiation effect of the optical fiber were studied. The detector has a relatively high n/γ sensitivity ratio, which increases as the diameter of the OSF decreases, and ratios greater than 10 could be achieved when the diameter of the OSF is less than 0.3 nun. The sensitivity of the detector to neutrons ranges from 10-14 to 10-20 C cm2/n, and has a response time of 3 ns (FWHM). The proposed detector is also highly flexible. For instance, the probe can be set close to the source, while the PMT can be placed far away from radiation, allowing easy shielding. Due to these characteristics, pulsed fission neutrons in the vicinity of the source can be accurately measured.展开更多
本文阐述了单球中子谱仪的原理,介绍了基于单慢化球和19对6Li-7Li闪烁体探测器构成的单球中子谱仪的结构及解谱方法,使用蒙特卡罗中子输运程序模拟了单球中子谱仪的中子响应函数。计算结果表明,该谱仪具有较好的空间对称性,能根据谱仪...本文阐述了单球中子谱仪的原理,介绍了基于单慢化球和19对6Li-7Li闪烁体探测器构成的单球中子谱仪的结构及解谱方法,使用蒙特卡罗中子输运程序模拟了单球中子谱仪的中子响应函数。计算结果表明,该谱仪具有较好的空间对称性,能根据谱仪中各探测器的计数对源的大致方位进行判断;模拟了单球谱仪在241Am-Be源照射下各探测器的计数,使用Unfolding with Maxed and Gravel (UMG)解谱程序在不同解谱算法以及初始谱的情况下对模拟数据进行解谱计算,在使用最大熵散发以及与源项相同的预置谱的情况下,解谱结果最为准确,验证了响应函数的准确性。展开更多
文摘To measure the pulsed neutron of a pulsed fission source, an organic scintillation fiber (OSF) detector with separation structure has been designed. The proposed detector employs UV optical fibers as the light guide, and the sensitive region of the detector is composed of a linear array of OSFs, which are individually connected to the optical fibers. The other end of the light guide is coupled to a photomultiplier tube. The key properties of the device including the energy response, time response, neutron sensitivity, and radiation effect of the optical fiber were studied. The detector has a relatively high n/γ sensitivity ratio, which increases as the diameter of the OSF decreases, and ratios greater than 10 could be achieved when the diameter of the OSF is less than 0.3 nun. The sensitivity of the detector to neutrons ranges from 10-14 to 10-20 C cm2/n, and has a response time of 3 ns (FWHM). The proposed detector is also highly flexible. For instance, the probe can be set close to the source, while the PMT can be placed far away from radiation, allowing easy shielding. Due to these characteristics, pulsed fission neutrons in the vicinity of the source can be accurately measured.
文摘本文阐述了单球中子谱仪的原理,介绍了基于单慢化球和19对6Li-7Li闪烁体探测器构成的单球中子谱仪的结构及解谱方法,使用蒙特卡罗中子输运程序模拟了单球中子谱仪的中子响应函数。计算结果表明,该谱仪具有较好的空间对称性,能根据谱仪中各探测器的计数对源的大致方位进行判断;模拟了单球谱仪在241Am-Be源照射下各探测器的计数,使用Unfolding with Maxed and Gravel (UMG)解谱程序在不同解谱算法以及初始谱的情况下对模拟数据进行解谱计算,在使用最大熵散发以及与源项相同的预置谱的情况下,解谱结果最为准确,验证了响应函数的准确性。