A substrate-ffee optical readout focal plane array (FPA) operating in 8-12 um with a heat sink structure (HSS) was fabricated and its performance was tested. The temperature distribution of the FPA with an HSS inv...A substrate-ffee optical readout focal plane array (FPA) operating in 8-12 um with a heat sink structure (HSS) was fabricated and its performance was tested. The temperature distribution of the FPA with an HSS investigated by using a commercial FLIR IR camera shows excellent uniformity. The thermal cross-talk effect existing in traditional substrate-free FPAs was eliminated effectively. The heat sink is fabricated successfully by electroplating copper, which provides high thermal capacity and high thermal conductivity, on the frame of substrate-free FPA. The FPA was tested in the optical-readout system, the results show that the response and NETD are 13.6 grey/K (F / # = 0.8) and 588 inK, respectively.展开更多
This paper designs a 3 × 3 light emitting diode (LED) array with a total power of 9 W, presents a thermal analysis of plate fin, in-line and staggered pin fin heat sinks for a high power LED lighting system, an...This paper designs a 3 × 3 light emitting diode (LED) array with a total power of 9 W, presents a thermal analysis of plate fin, in-line and staggered pin fin heat sinks for a high power LED lighting system, and develops a 3D one-fourth finite element (FE) model to predict the system temperature distribution. Three kinds of heat sinks are compared under the same conditions. It is found that LED chip junction temperature is 48.978℃ when the fins of heat sink are aligned alternately.展开更多
With the increase of high-power electrical components in modern ships,especially fully electric ships with electric propulsion drive(EPD),the cooling of EPD electrical components has become particularly important.Prov...With the increase of high-power electrical components in modern ships,especially fully electric ships with electric propulsion drive(EPD),the cooling of EPD electrical components has become particularly important.Providing optimal configurations for heat sinks with high thermal efficiency plays an essential role in this regard.A new technique for improving the efficiency of heat sinks is the utilization of perforated fins.This study examined the effects of perforation geometry(shape and size)on laminar airflow flow and heat transfer characteristics over a perforated plate-fin heat sink.Three-dimensional simulations were conducted using the finite-volume scheme based on the SIMPLE algorithm.In this research,the effects of perforation shape and size on various parameters,e.g.,total drag force,average Nusselt number,perforated fin efficiency(PFE),heat transfer performance enhancement(HTPE),and fin optimization factor(η)were evaluated.The results confirmed that at a specific heat transfer surface area for perforated fins,the highest efficiency is achieved by circular perforations.In contrast,the square perforations due to geometric similarity to rectangular fins could reach the maximum size.Consequently,fins with square perforations could achieve the most optimal configuration.Also,results showed that for a constant perforations size,change in perforations shape improves HTPE,PFE,andηby more than 40%,45%,and 110%,respectively.Also,by modifying perforations size for a specified shape,an increment of more than 35%,40%,and 150%is observed in HTPE,PFE,andη,respectively.展开更多
基金Project supported by the Chinese Academy of Sciences Knowledge Innovation Project(No.07YF031001)the Natural Science Foundation of Jiangsu Province,China(No.BK2012219),the Key Lab of Microelectronics Device and Integration Technology,China
文摘A substrate-ffee optical readout focal plane array (FPA) operating in 8-12 um with a heat sink structure (HSS) was fabricated and its performance was tested. The temperature distribution of the FPA with an HSS investigated by using a commercial FLIR IR camera shows excellent uniformity. The thermal cross-talk effect existing in traditional substrate-free FPAs was eliminated effectively. The heat sink is fabricated successfully by electroplating copper, which provides high thermal capacity and high thermal conductivity, on the frame of substrate-free FPA. The FPA was tested in the optical-readout system, the results show that the response and NETD are 13.6 grey/K (F / # = 0.8) and 588 inK, respectively.
基金Project supported by the National Natural Science Foundation of China(No.60666002)
文摘This paper designs a 3 × 3 light emitting diode (LED) array with a total power of 9 W, presents a thermal analysis of plate fin, in-line and staggered pin fin heat sinks for a high power LED lighting system, and develops a 3D one-fourth finite element (FE) model to predict the system temperature distribution. Three kinds of heat sinks are compared under the same conditions. It is found that LED chip junction temperature is 48.978℃ when the fins of heat sink are aligned alternately.
文摘With the increase of high-power electrical components in modern ships,especially fully electric ships with electric propulsion drive(EPD),the cooling of EPD electrical components has become particularly important.Providing optimal configurations for heat sinks with high thermal efficiency plays an essential role in this regard.A new technique for improving the efficiency of heat sinks is the utilization of perforated fins.This study examined the effects of perforation geometry(shape and size)on laminar airflow flow and heat transfer characteristics over a perforated plate-fin heat sink.Three-dimensional simulations were conducted using the finite-volume scheme based on the SIMPLE algorithm.In this research,the effects of perforation shape and size on various parameters,e.g.,total drag force,average Nusselt number,perforated fin efficiency(PFE),heat transfer performance enhancement(HTPE),and fin optimization factor(η)were evaluated.The results confirmed that at a specific heat transfer surface area for perforated fins,the highest efficiency is achieved by circular perforations.In contrast,the square perforations due to geometric similarity to rectangular fins could reach the maximum size.Consequently,fins with square perforations could achieve the most optimal configuration.Also,results showed that for a constant perforations size,change in perforations shape improves HTPE,PFE,andηby more than 40%,45%,and 110%,respectively.Also,by modifying perforations size for a specified shape,an increment of more than 35%,40%,and 150%is observed in HTPE,PFE,andη,respectively.