A bionic flexible manipulator driven by pneumatic muscle actuator(PMA)can better reflect the flexibility of the mechanism.Current research on PMA mainly focuses on the modeling and control strategy of the pneumatic ma...A bionic flexible manipulator driven by pneumatic muscle actuator(PMA)can better reflect the flexibility of the mechanism.Current research on PMA mainly focuses on the modeling and control strategy of the pneumatic manipulator system.Compared with traditional electro-hydraulic actuators,the structure of PMA is simple but possesses strong nonlinearity and flexibility,which leads to the difficulty in improving the control accuracy.In this paper,the configuration design of a bionic flexible manipulator is performed by human physiological map,the kinematic model of the mechanism is established,and the dynamics is analyzed by Lagrange method.A fuzzy torque control algorithm is designed based on the computed torque method,where the fuzzy control theory is applied.The hardware experimental system is established.Through the co-simulation contrast test on MATLAB and ADAMS,it is found that the fuzzy torque control algorithm has better tracking performance and higher tracking accuracy than the computed torque method,and is applied to the entity control test.The experimental results show that the fuzzy torque algorithm can better control the trajectory tracking movement of the bionic flexible manipulator.This research proposes a fuzzy torque control algorithm which can compensate the error more effectively,and possesses the preferred trajectory tracking performance.展开更多
The pneumatic muscle actuator(PMA)has many advantages,such as good flexibility,high power/weight ratio,but its nonlinearity makes it difficult to build a static mathematical model with high precision.A new method is p...The pneumatic muscle actuator(PMA)has many advantages,such as good flexibility,high power/weight ratio,but its nonlinearity makes it difficult to build a static mathematical model with high precision.A new method is proposed to establish the model of PMA.The concept of hybrid elastic modulus which is related to the static characteristic of PMA is put forward,and the energy conservation law is used to achieve the expression of the hybrid elastic modulus,which can be fitted out based on experimental data,and the model of PMA can be derived from this expression.At the same time,a 3-DOF parallel mechanism(a new bionic shoulder joint)driven by five PMAs is designed.This bionic shoulder joint adopts the structure of two antagonistic PMAs actualizing a rotation control and three PMAs controlling another two rotations to get better rotation characteristics.The kinematic and dynamic characteristics of the mechanism are analyzed and a new static model of PMA is used to control it.Experimental results demonstrate the effectiveness of this new static model.展开更多
The aim of this article is to provide a survey on the most popular modeling approaches for PMAs (pneumatic muscle actuators). PMAs are highly non-linear pneumatic actuators where their elongation is proportional to ...The aim of this article is to provide a survey on the most popular modeling approaches for PMAs (pneumatic muscle actuators). PMAs are highly non-linear pneumatic actuators where their elongation is proportional to the interval pressure. During the last decade, there has been an increase in the industrial and scientific utilization of PMAs, due to their advantages such as high strength and small weight, while various types of PMAs with different technical characteristics have appeared in the literature. This article will: (a) analyse the PMA's operation from a mathematical modeling perspective; (b) present their merits and drawbacks of the most common PMAs; and (c) establish the fundamental basis for developing industrial applications and conducting research in this field.展开更多
The control of single pneumatic muscle actuator is studied, as one basic partof research on the parallel-robot arthrosis actuated by pneumatic muscle actuators. Experimentsshow that a self-modified fuzzy-PID controlle...The control of single pneumatic muscle actuator is studied, as one basic partof research on the parallel-robot arthrosis actuated by pneumatic muscle actuators. Experimentsshow that a self-modified fuzzy-PID controller is obviously effective for its position servo and asimple PID controller is good for its force track.展开更多
The PID, fuzzy, self-organized fuzzy and self-organized fuzzy-PID controllers are adopted in the position control of single pneumatic muscle actuator. Experiments show that the self-organized fuzzy-PID is obviously ef...The PID, fuzzy, self-organized fuzzy and self-organized fuzzy-PID controllers are adopted in the position control of single pneumatic muscle actuator. Experiments show that the self-organized fuzzy-PID is obviously effective for the position control of single pneumatic muscle actuator, which can realize precision within 0.3 mm and withstand 18?N variable load plus about 36?N fixed load. It is relatively precise and robust.展开更多
In recent years, researchers have been actively pursuing research into developing robots that can be useful in many fields of industry (e.g., service, medical, and aging care). Such robots must be safe and flexible ...In recent years, researchers have been actively pursuing research into developing robots that can be useful in many fields of industry (e.g., service, medical, and aging care). Such robots must be safe and flexible so that they can coexist with people. Pneumatic actuators are useful for achieving this goal because they are lightweight units with natural compliance. Our research focuses on joint angle control for a pneumatically driven musculoskeletal model. In such a model, we use a one-degree-of-freedom joint model and a five-fingered robot hand as test beds. These models are driven by low pressure-driven pneumatic actuators, and mimic the mechanism of the human hand and musculoskeletal structure, which has an antagonistic muscle pair for each joint. We demonstrated a biologically inspired control method using the parameters antagonistic muscle ratio and antagonistic muscle activity. The concept of the method is based on coordination of an antagonistic muscle pair using these parameters. We have investigated the validity of the proposed method both theoretically and experimentally, developed a feedback control system, and conducted joint angle control by implementing the test beds.展开更多
Actuator plays a significant role in soft robotics.This paper proposed an ultralong stretchable soft actuator(US2A)with a variable and sizeable maximum elongation.The US2A is composed of a silicone rubber tube and a b...Actuator plays a significant role in soft robotics.This paper proposed an ultralong stretchable soft actuator(US2A)with a variable and sizeable maximum elongation.The US2A is composed of a silicone rubber tube and a bellows woven sleeve.The maximal extension can be conveniently regulated by just adjusting the wrinkles’initial angle of the bellows woven sleeve.The kinematics of US2A could be obtained by geometrically analyzing the structure of the bellows woven sleeve when the silicone rubber tube is inflated.Based on the principle of virtual work,the actuating models have been established:the pressure-elongation model and the pressure-force model.These models reflect the influence of the silicone tube’s shell thickness and material properties on the pneumatic muscle’s performance,which facilitates the optimal design of US2A for various working conditions.The experimental results showed that the maximum elongation of the US2A prototype is 257%,and the effective elongation could be variably regulated in the range of 0 and 257%.The proposed models were also verified by pressure-elongation and pressure-force experiments,with an average error of 5%and 2.5%,respectively.Finally,based on the US2A,we designed a pneumatic rehabilitation glove,soft arm robot,and rigid-soft coupling continuous robot,which further verified the feasibility of US2A as a soft driving component.展开更多
基金Supported by National Natural Science Foundation of China(Grant No.51405229)Jiangsu Provincial Natural Science Foundation of China(Grant No.BK20151470)
文摘A bionic flexible manipulator driven by pneumatic muscle actuator(PMA)can better reflect the flexibility of the mechanism.Current research on PMA mainly focuses on the modeling and control strategy of the pneumatic manipulator system.Compared with traditional electro-hydraulic actuators,the structure of PMA is simple but possesses strong nonlinearity and flexibility,which leads to the difficulty in improving the control accuracy.In this paper,the configuration design of a bionic flexible manipulator is performed by human physiological map,the kinematic model of the mechanism is established,and the dynamics is analyzed by Lagrange method.A fuzzy torque control algorithm is designed based on the computed torque method,where the fuzzy control theory is applied.The hardware experimental system is established.Through the co-simulation contrast test on MATLAB and ADAMS,it is found that the fuzzy torque control algorithm has better tracking performance and higher tracking accuracy than the computed torque method,and is applied to the entity control test.The experimental results show that the fuzzy torque algorithm can better control the trajectory tracking movement of the bionic flexible manipulator.This research proposes a fuzzy torque control algorithm which can compensate the error more effectively,and possesses the preferred trajectory tracking performance.
基金supported by the National Natural Science Foundation of China(No. 51405229)the Natural Science Foundation of Jiangsu Province of China(Nos. BK20151470,BK20171416)
文摘The pneumatic muscle actuator(PMA)has many advantages,such as good flexibility,high power/weight ratio,but its nonlinearity makes it difficult to build a static mathematical model with high precision.A new method is proposed to establish the model of PMA.The concept of hybrid elastic modulus which is related to the static characteristic of PMA is put forward,and the energy conservation law is used to achieve the expression of the hybrid elastic modulus,which can be fitted out based on experimental data,and the model of PMA can be derived from this expression.At the same time,a 3-DOF parallel mechanism(a new bionic shoulder joint)driven by five PMAs is designed.This bionic shoulder joint adopts the structure of two antagonistic PMAs actualizing a rotation control and three PMAs controlling another two rotations to get better rotation characteristics.The kinematic and dynamic characteristics of the mechanism are analyzed and a new static model of PMA is used to control it.Experimental results demonstrate the effectiveness of this new static model.
文摘The aim of this article is to provide a survey on the most popular modeling approaches for PMAs (pneumatic muscle actuators). PMAs are highly non-linear pneumatic actuators where their elongation is proportional to the interval pressure. During the last decade, there has been an increase in the industrial and scientific utilization of PMAs, due to their advantages such as high strength and small weight, while various types of PMAs with different technical characteristics have appeared in the literature. This article will: (a) analyse the PMA's operation from a mathematical modeling perspective; (b) present their merits and drawbacks of the most common PMAs; and (c) establish the fundamental basis for developing industrial applications and conducting research in this field.
文摘The control of single pneumatic muscle actuator is studied, as one basic partof research on the parallel-robot arthrosis actuated by pneumatic muscle actuators. Experimentsshow that a self-modified fuzzy-PID controller is obviously effective for its position servo and asimple PID controller is good for its force track.
文摘The PID, fuzzy, self-organized fuzzy and self-organized fuzzy-PID controllers are adopted in the position control of single pneumatic muscle actuator. Experiments show that the self-organized fuzzy-PID is obviously effective for the position control of single pneumatic muscle actuator, which can realize precision within 0.3 mm and withstand 18?N variable load plus about 36?N fixed load. It is relatively precise and robust.
文摘In recent years, researchers have been actively pursuing research into developing robots that can be useful in many fields of industry (e.g., service, medical, and aging care). Such robots must be safe and flexible so that they can coexist with people. Pneumatic actuators are useful for achieving this goal because they are lightweight units with natural compliance. Our research focuses on joint angle control for a pneumatically driven musculoskeletal model. In such a model, we use a one-degree-of-freedom joint model and a five-fingered robot hand as test beds. These models are driven by low pressure-driven pneumatic actuators, and mimic the mechanism of the human hand and musculoskeletal structure, which has an antagonistic muscle pair for each joint. We demonstrated a biologically inspired control method using the parameters antagonistic muscle ratio and antagonistic muscle activity. The concept of the method is based on coordination of an antagonistic muscle pair using these parameters. We have investigated the validity of the proposed method both theoretically and experimentally, developed a feedback control system, and conducted joint angle control by implementing the test beds.
基金National Natural Science Foundation of China(Grant No.U2013212)Key Research and Development Program of Zhejiang(Grant No.2021C04015)Fundamental Research Funds for the Provincial Universities of Zhejiang(Grant No.RF-C2019004)。
文摘Actuator plays a significant role in soft robotics.This paper proposed an ultralong stretchable soft actuator(US2A)with a variable and sizeable maximum elongation.The US2A is composed of a silicone rubber tube and a bellows woven sleeve.The maximal extension can be conveniently regulated by just adjusting the wrinkles’initial angle of the bellows woven sleeve.The kinematics of US2A could be obtained by geometrically analyzing the structure of the bellows woven sleeve when the silicone rubber tube is inflated.Based on the principle of virtual work,the actuating models have been established:the pressure-elongation model and the pressure-force model.These models reflect the influence of the silicone tube’s shell thickness and material properties on the pneumatic muscle’s performance,which facilitates the optimal design of US2A for various working conditions.The experimental results showed that the maximum elongation of the US2A prototype is 257%,and the effective elongation could be variably regulated in the range of 0 and 257%.The proposed models were also verified by pressure-elongation and pressure-force experiments,with an average error of 5%and 2.5%,respectively.Finally,based on the US2A,we designed a pneumatic rehabilitation glove,soft arm robot,and rigid-soft coupling continuous robot,which further verified the feasibility of US2A as a soft driving component.