期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Electrochemical corrosion behavior of arc sprayed Al-Zn-Si-RE coatings on mild steel in 3.5% NaCl solution 被引量:6
1
作者 蒋穹 缪强 +4 位作者 仝飞 徐一 任蓓蕾 刘志梅 姚正军 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第8期2713-2722,共10页
Al-Zn-Si-RE coating with high Al content was deposited on mild steel by arc spraying. The electrochemical behavior of Al-Zn-Si-RE coating in 3.5%NaCl solution was systematically studied by potentiodynamic polarization... Al-Zn-Si-RE coating with high Al content was deposited on mild steel by arc spraying. The electrochemical behavior of Al-Zn-Si-RE coating in 3.5%NaCl solution was systematically studied by potentiodynamic polarization, corrosion potential (φcor ) and electrochemical impedance spectroscopy techniques (EIS). The impedance data were fitted to appropriate equivalent circuits to explain the different electrochemical processes occurring at the electrode-electrolyte interface. The results indicate that Al-Zn-Si-RE coating reveals the similar polarization behavior as Zn-15Al coating. The coating has no passive region in the anodic polarization, but far lower corrosion current and much higher corrosion potential. Al-Zn-Si-RE coating provides effective sacrificial protection for steel substrate and the sacrificial anodic protection plays dominant role during the immersion process. In addition, theφcor evolution and EIS plots indicate that the corrosion process can be divided into five stages: pitting-dissolution-redeposition, activation corrosion, cathodic protection, physical barriers and the coating failure. 展开更多
关键词 Al-Zn-Si-RE coating corrosion potential corrosion behavior polarization plots electrochemical impedance spectroscopy
下载PDF
Static Laser Light Scattering Studies from Red Blood Cells
2
作者 David Joseph Amit Kumar 《Optics and Photonics Journal》 2016年第10期237-260,共24页
A homemade Static Light scattering studies has been used to determine angle resolved scattered intensity for different polarization states of the incident laser light. Classical light scattering set ups are being used... A homemade Static Light scattering studies has been used to determine angle resolved scattered intensity for different polarization states of the incident laser light. Classical light scattering set ups are being used to study morphological aspects of scatterers using simple set ups using low power lasers. Red blood cells form rather interesting as well as a challenging system for scattering experiments. The scattering spectrometer consists of a scattering arm, a scattering turn table and collimating arm. Along with polarizers integrated in the collimating arm as well as scattering arms ensures collection of scattered flux with the required polarization state. This technique is being developed for its in vitro studies using fresh red blood cells. A brief review of the theoretical models used for scattering from Red Blood Cells (RBC) has been discussed in the paper. Scattering pattern (scattering plots) as well as polar plots of scattered flux have been determined for different polarization state of the incident light. Insight into the orientation of major axis of particles can be inferred from the polar plots. 展开更多
关键词 Raleigh Scattering Mie Scattering Red Blood Cells Polar plots Clustering Circularly Polarized Light Linearly Polarized Light POLARIZER Scattering Turn Table Collimator Arm Scattering Arm
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部