Polarization pattern provides additional information besides spectral signatures. It can be used in many applications, such as navigation, defect detection and object identification. A novel polarization camera compos...Polarization pattern provides additional information besides spectral signatures. It can be used in many applications, such as navigation, defect detection and object identification. A novel polarization camera composed of four synchronized cameras is proposed, and it can realize real-time polarization measurement. This study particularly concentrates on the geometric calibration of the system. The projection model is analyzed and the multi-camera calibration algorithm is proposed. Firstly, each camera is calibrated separately using planar patterns, and then the geometric calibration algorithms are performed. Due to the geometrical constraint, a global optimization method results in smaller estimation uncertainties. A mean rotation error of 0.025?and a mean translation error of 0.26 mm are achieved after geometric calibration. The images are rectified to establish a correspondence among cameras and are combined to acquire the polarization measurement. The polarization pattern of the skylight is measured by the system and the results are consistent with the previous studies.展开更多
This letter shows that the human eye fundus tissue has higher reflectivity at the near-infrared (NIR) wavelength, and that some aberrations exist at the pre-optical system from cornea to vitreous. We design a NIR fu...This letter shows that the human eye fundus tissue has higher reflectivity at the near-infrared (NIR) wavelength, and that some aberrations exist at the pre-optical system from cornea to vitreous. We design a NIR fundus camera with inner focusing, which can be applied to the -10 D to 10 D range of vision and has the advantage of ensuring the stability of image when is focused. Considered as Liou's eye aberration model, we correct the integrated aberration to ensure a 100 lp/mm resolution when we complete the assembly and calibration of the fundus camera. Kohler illumination is also applied to obtain uniform fundus illumination. Moreover, we put forward a novel method for stray light elimination based on polarization switch, which inhibits ghost image formation near the focal plane when the illumination beam is reflected by the eyepiece surface. The result shows that this method is effective in ensuring an illumination uniformity of 80%, with the advantage of simple structure and easy assembly.展开更多
基金the National Natural Science Foundation of China(Nos.61503403 and 61573371)the Research Project of National University of Defense Technology(No.JC 14-03-04)
文摘Polarization pattern provides additional information besides spectral signatures. It can be used in many applications, such as navigation, defect detection and object identification. A novel polarization camera composed of four synchronized cameras is proposed, and it can realize real-time polarization measurement. This study particularly concentrates on the geometric calibration of the system. The projection model is analyzed and the multi-camera calibration algorithm is proposed. Firstly, each camera is calibrated separately using planar patterns, and then the geometric calibration algorithms are performed. Due to the geometrical constraint, a global optimization method results in smaller estimation uncertainties. A mean rotation error of 0.025?and a mean translation error of 0.26 mm are achieved after geometric calibration. The images are rectified to establish a correspondence among cameras and are combined to acquire the polarization measurement. The polarization pattern of the skylight is measured by the system and the results are consistent with the previous studies.
基金supported by the National Natural Science Foundation of China(Nos.60977008and60678048)the National Ministry Education Fund for Doctoral of China(No.20103219110014)the Chinese Academy of Sciences Key Laboratory Fund(No.2008DP173445)
文摘This letter shows that the human eye fundus tissue has higher reflectivity at the near-infrared (NIR) wavelength, and that some aberrations exist at the pre-optical system from cornea to vitreous. We design a NIR fundus camera with inner focusing, which can be applied to the -10 D to 10 D range of vision and has the advantage of ensuring the stability of image when is focused. Considered as Liou's eye aberration model, we correct the integrated aberration to ensure a 100 lp/mm resolution when we complete the assembly and calibration of the fundus camera. Kohler illumination is also applied to obtain uniform fundus illumination. Moreover, we put forward a novel method for stray light elimination based on polarization switch, which inhibits ghost image formation near the focal plane when the illumination beam is reflected by the eyepiece surface. The result shows that this method is effective in ensuring an illumination uniformity of 80%, with the advantage of simple structure and easy assembly.