A fluorescence polarization immunoassay (FPIA) was developed for the analysis ofaflatoxins (AFs) using an anti-aflatoxin B1 (AFB1) monoclonal antibody and a novel fluorescein-labeled AFB1 tracer. The FPIA showed...A fluorescence polarization immunoassay (FPIA) was developed for the analysis ofaflatoxins (AFs) using an anti-aflatoxin B1 (AFB1) monoclonal antibody and a novel fluorescein-labeled AFB1 tracer. The FPIA showed an IC50 value of 23.33 ng/mL with a limit of detection of 13.12 ng/mL for AFB1. The cross-reactivities of AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2 with the antibody were 100%, 65.7%, 143%, 23.5%, 111.4%, and 2%, respectively. The group-specificity of anti-AFB1mAb indicated that the FPIA could potentially be used in a screening method for the detection of total AFs, albeit not AFG2 and AFM2. The total time required for analyzing 96 samples in one microplate was less than 5 rain. This study demonstrates the potential usefulness of the FPIA as a rapid and simple technique for monitoring AFs.展开更多
A compact linearly polarized, low-noise, narrow-linewidth, single-frequency fiber laser at 1950nm is demonstrated. This compact fiber laser is based on a 21-mm-long homemade Tm3+-doped germanate glass fiber. Over 100...A compact linearly polarized, low-noise, narrow-linewidth, single-frequency fiber laser at 1950nm is demonstrated. This compact fiber laser is based on a 21-mm-long homemade Tm3+-doped germanate glass fiber. Over 100-mW stable continuous-wave single transverse and longitudinal mode lasing at 195Ohm are achieved. The measured relative intensity noise is less than -135dB/Hz at frequencies over 5 MHz. The signal-to-noise ratio of the laser is larger than 72dB, and the laser linewidth is less than 6kHz, while the obtained linear polarization extinction ratio is higher than 22 dB.展开更多
基金supported by grants from the International Science&Technology Cooperation Program of China(2009DFA32330)the Special Fund for Agro-scientific Research in the Public Interest(No.201203040)
文摘A fluorescence polarization immunoassay (FPIA) was developed for the analysis ofaflatoxins (AFs) using an anti-aflatoxin B1 (AFB1) monoclonal antibody and a novel fluorescein-labeled AFB1 tracer. The FPIA showed an IC50 value of 23.33 ng/mL with a limit of detection of 13.12 ng/mL for AFB1. The cross-reactivities of AFB1, AFB2, AFG1, AFG2, AFM1, and AFM2 with the antibody were 100%, 65.7%, 143%, 23.5%, 111.4%, and 2%, respectively. The group-specificity of anti-AFB1mAb indicated that the FPIA could potentially be used in a screening method for the detection of total AFs, albeit not AFG2 and AFM2. The total time required for analyzing 96 samples in one microplate was less than 5 rain. This study demonstrates the potential usefulness of the FPIA as a rapid and simple technique for monitoring AFs.
基金Supported by the National High-Technology Research and Development Program of China under Grant Nos 2013AA031502 and 2014AA041902the National Natural Science Foundation of China under Grant Nos 11174085,51132004,and 51302086+3 种基金the Natural Science Foundation of Guangdong Province under Grant Nos S2011030001349 and S20120011380the China National Funds for Distinguished Young Scientists under Grant No 61325024the Science and Technology Project of Guangdong Province under Grant No 2013B090500028the ’Cross and Cooperative’ Science and Technology Innovation Team Project of Chinese Academy of Sciences under Grant No 2012-119
文摘A compact linearly polarized, low-noise, narrow-linewidth, single-frequency fiber laser at 1950nm is demonstrated. This compact fiber laser is based on a 21-mm-long homemade Tm3+-doped germanate glass fiber. Over 100-mW stable continuous-wave single transverse and longitudinal mode lasing at 195Ohm are achieved. The measured relative intensity noise is less than -135dB/Hz at frequencies over 5 MHz. The signal-to-noise ratio of the laser is larger than 72dB, and the laser linewidth is less than 6kHz, while the obtained linear polarization extinction ratio is higher than 22 dB.