A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine)(Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse vol...A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine)(Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse voltammetry (DPV) for the first time. The electrochemical properties of the Co-poly(Met)/GCE were analysed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to characterize the polymers on the GCE surface. The deposition of the Co-poly(Met) film on the GCE surface enhanced the sensor electronic transfer. CV studies revealed that estriol exhibits an irreversible oxidation peak at t0.58 V for the Co-poly(Met)/GCE (vs. Ag/AgCl reference electrode) in 0.10 mol/L Britton-Robinson buffer solution (pH=7.0). Different voltammetric scan rates (10-200 mV/s) suggested that the estriol oxidation on the Co-poly(Met)/GCE surface is controlled by adsorption and diffusion processes. Based on the optimized DPV conditions, the linear responses for estriol quantification were from 0.596 μmol/L to 4.76 μmol/L (R2 =0.996) and from 5.66 μmol/L to 9.90 μmol/L (R2 =0.994) with a limit of detection (LOD) of 0.0340 μmol/L and a limit of quantification (LOQ) of 0.113 μmol/L. The DPV-Co-poly(Met)/GCE method provided good intra-day and inter-day repeatability with RSD values lower than 5%. Also, no interference of real sample matrices was observed on the estriol voltammetric response, making the DPV-Copoly( Met)/GCE highly selective for estriol. The accuracy test showed that the estriol recovery was in the ranges 96.7%-103% and 98.7%-102% for pharmaceutical tablets and human urine, respectively. The estriol quantification in pharmaceutical tablets performed by the Co-poly(Met)/GCE-assisted DPV method was comparable to the official analytical protocols.展开更多
目的:建立一种聚甲苯胺蓝修饰电极测定尿酸的新方法,为人体内尿酸含量的测定提出一条新的思路。方法:利用甲苯胺蓝在玻碳电极表面制备聚合物膜,用循环伏安法研究了尿酸(UA)在该电极上的电化学行为,并将电极用于实际尿样的测定。结果:在0...目的:建立一种聚甲苯胺蓝修饰电极测定尿酸的新方法,为人体内尿酸含量的测定提出一条新的思路。方法:利用甲苯胺蓝在玻碳电极表面制备聚合物膜,用循环伏安法研究了尿酸(UA)在该电极上的电化学行为,并将电极用于实际尿样的测定。结果:在0.1 mol·L^(-1)(pH 7.0)的磷酸盐缓冲液中,UA 在聚甲苯胺蓝修饰电极上于0.373 V 处产生一灵敏的氧化峰,线性扫描伏安法测定其氧化峰电流与 UA 浓度在8×10^(-6)~3.0×10^(14)mol·L^(-1)范围内呈良好的线性关系(r=0.9971),检出限为5.0×10^(-6)mol·L^(-1)。结论:该电极制作简单,重现性好,可以用于实际尿样的测定,结果令人满意。展开更多
A simple and highly sensitive analysis by electrochemical voltammetry has been developed for diagnosis of the most destructive crop disease in Thailand known as sugarcane white leaf (SCWL). Determination of the corres...A simple and highly sensitive analysis by electrochemical voltammetry has been developed for diagnosis of the most destructive crop disease in Thailand known as sugarcane white leaf (SCWL). Determination of the corresponding DNA interaction has been obtained from the voltammetric signals of electroactive redox methylene blue (MB) by means of cyclic and differential pulse voltammetry. In this study, a chitosan-modified glassy carbon electrode (GCE) was created by self-assembly to produce electrostatic platform for effective immobilization of the DNA. Fabrication of SCWL-DNA hybridization detection system was performed by immobilizing the ssDNA probe as a specific sensor onto chitosan-modified GCE. Hybridization of complementary DNA from the real samples could then be detected by its respective MB signal. This fabricated DNA probe sensor was shown to be capable for discriminative identification among the DNAs from SCWL plants, mosaic virus infected sugarcane and healthy sugarcane plants. Relationship between the specific hybridization signal and DNA target concentration was also observed under optimal condition. The detection limit of 4.709 ng/μl with the regression coefficient (R2) of 0.998 and overall RSD of 2.44% were obtained by response curve fit analysis. The actual SCWL-ssDNA immobilization and hybridizing event were subsequently confirmed by an observation under atomic force microscope. Thus these experiments demonstrate the first successful and effective DNA based voltammetric electrochemical determination for a verification of the specific pathogenic infection within plants from the real epidemic field.展开更多
基金CNPq (454438/2014-1)CAPES+1 种基金FINEPFAPEMIG for the financial support to this work
文摘A voltammetric sensor based on the electropolymerization of cobalt-poly(methionine)(Co-poly(Met)) on a glassy carbon electrode (GCE) was developed and applied for the determination of estriol by differential pulse voltammetry (DPV) for the first time. The electrochemical properties of the Co-poly(Met)/GCE were analysed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to characterize the polymers on the GCE surface. The deposition of the Co-poly(Met) film on the GCE surface enhanced the sensor electronic transfer. CV studies revealed that estriol exhibits an irreversible oxidation peak at t0.58 V for the Co-poly(Met)/GCE (vs. Ag/AgCl reference electrode) in 0.10 mol/L Britton-Robinson buffer solution (pH=7.0). Different voltammetric scan rates (10-200 mV/s) suggested that the estriol oxidation on the Co-poly(Met)/GCE surface is controlled by adsorption and diffusion processes. Based on the optimized DPV conditions, the linear responses for estriol quantification were from 0.596 μmol/L to 4.76 μmol/L (R2 =0.996) and from 5.66 μmol/L to 9.90 μmol/L (R2 =0.994) with a limit of detection (LOD) of 0.0340 μmol/L and a limit of quantification (LOQ) of 0.113 μmol/L. The DPV-Co-poly(Met)/GCE method provided good intra-day and inter-day repeatability with RSD values lower than 5%. Also, no interference of real sample matrices was observed on the estriol voltammetric response, making the DPV-Copoly( Met)/GCE highly selective for estriol. The accuracy test showed that the estriol recovery was in the ranges 96.7%-103% and 98.7%-102% for pharmaceutical tablets and human urine, respectively. The estriol quantification in pharmaceutical tablets performed by the Co-poly(Met)/GCE-assisted DPV method was comparable to the official analytical protocols.
文摘目的:建立一种聚甲苯胺蓝修饰电极测定尿酸的新方法,为人体内尿酸含量的测定提出一条新的思路。方法:利用甲苯胺蓝在玻碳电极表面制备聚合物膜,用循环伏安法研究了尿酸(UA)在该电极上的电化学行为,并将电极用于实际尿样的测定。结果:在0.1 mol·L^(-1)(pH 7.0)的磷酸盐缓冲液中,UA 在聚甲苯胺蓝修饰电极上于0.373 V 处产生一灵敏的氧化峰,线性扫描伏安法测定其氧化峰电流与 UA 浓度在8×10^(-6)~3.0×10^(14)mol·L^(-1)范围内呈良好的线性关系(r=0.9971),检出限为5.0×10^(-6)mol·L^(-1)。结论:该电极制作简单,重现性好,可以用于实际尿样的测定,结果令人满意。
文摘A simple and highly sensitive analysis by electrochemical voltammetry has been developed for diagnosis of the most destructive crop disease in Thailand known as sugarcane white leaf (SCWL). Determination of the corresponding DNA interaction has been obtained from the voltammetric signals of electroactive redox methylene blue (MB) by means of cyclic and differential pulse voltammetry. In this study, a chitosan-modified glassy carbon electrode (GCE) was created by self-assembly to produce electrostatic platform for effective immobilization of the DNA. Fabrication of SCWL-DNA hybridization detection system was performed by immobilizing the ssDNA probe as a specific sensor onto chitosan-modified GCE. Hybridization of complementary DNA from the real samples could then be detected by its respective MB signal. This fabricated DNA probe sensor was shown to be capable for discriminative identification among the DNAs from SCWL plants, mosaic virus infected sugarcane and healthy sugarcane plants. Relationship between the specific hybridization signal and DNA target concentration was also observed under optimal condition. The detection limit of 4.709 ng/μl with the regression coefficient (R2) of 0.998 and overall RSD of 2.44% were obtained by response curve fit analysis. The actual SCWL-ssDNA immobilization and hybridizing event were subsequently confirmed by an observation under atomic force microscope. Thus these experiments demonstrate the first successful and effective DNA based voltammetric electrochemical determination for a verification of the specific pathogenic infection within plants from the real epidemic field.