A novel polyacrylaminothiourea chelating fiber was synthesized simply andrapidly from nitrilon (an acrylonitrile-based synthetic fiber), which was applied to preconcentrateand separate of trace amount of Au(III), Pt(I...A novel polyacrylaminothiourea chelating fiber was synthesized simply andrapidly from nitrilon (an acrylonitrile-based synthetic fiber), which was applied to preconcentrateand separate of trace amount of Au(III), Pt(IV), Pd(IV) and Ir(IV) ions from solution of samples.The analyzed ions can be quantitatively concentrated by the fiber up to a flow rate of 20.0 mL/minat pH 2, and can also be desorbed with 15 mL of 4 mol/L HCl+3% thiourea from the fiber column withrecoveries of 96.5%-100%. The chelating fiber can be reused for ten times, the recoveries of theseions are still over 92%, and hundred to thousand times of excess of Fe(III), Al(III), Ca(II),Mg(II), Ni(II), Mn(II), Cu(II), Zn(II), and Cd(II) cause no interference on the determination of theanalyzed ions by inductively-coupled plasma atomic emission spectrometry (ICP-AES). The staticsaturation adsorption capacities of the fiber for the analytes are in the range of 1.15-2.80 mmol/g.The relative standard deviations for the determination of 20.0 ng/mL each of Au(III), Pt(IV),Pd(IV) and Ir(IV) are in the range of 0.7%-3.0%. The recoveries for test from standard additions toreal solution samples are between 96% and 100%. The concentration of each ion in powder sampledetected by the method is in good agreement with the certified value.展开更多
基金theNaturalScienceFoundationofNingxia ,China (No .199912 )andtheScienceCommitteeFoundationofNingx ia ,China
文摘A novel polyacrylaminothiourea chelating fiber was synthesized simply andrapidly from nitrilon (an acrylonitrile-based synthetic fiber), which was applied to preconcentrateand separate of trace amount of Au(III), Pt(IV), Pd(IV) and Ir(IV) ions from solution of samples.The analyzed ions can be quantitatively concentrated by the fiber up to a flow rate of 20.0 mL/minat pH 2, and can also be desorbed with 15 mL of 4 mol/L HCl+3% thiourea from the fiber column withrecoveries of 96.5%-100%. The chelating fiber can be reused for ten times, the recoveries of theseions are still over 92%, and hundred to thousand times of excess of Fe(III), Al(III), Ca(II),Mg(II), Ni(II), Mn(II), Cu(II), Zn(II), and Cd(II) cause no interference on the determination of theanalyzed ions by inductively-coupled plasma atomic emission spectrometry (ICP-AES). The staticsaturation adsorption capacities of the fiber for the analytes are in the range of 1.15-2.80 mmol/g.The relative standard deviations for the determination of 20.0 ng/mL each of Au(III), Pt(IV),Pd(IV) and Ir(IV) are in the range of 0.7%-3.0%. The recoveries for test from standard additions toreal solution samples are between 96% and 100%. The concentration of each ion in powder sampledetected by the method is in good agreement with the certified value.