Carbon nanofibers have revolutionized nanotechnology due to their potential applications in emerging frontiers of research and industrial sectors. This can be attributed to their superior properties such as higher mec...Carbon nanofibers have revolutionized nanotechnology due to their potential applications in emerging frontiers of research and industrial sectors. This can be attributed to their superior properties such as higher mechanical strength, unique surface characteristics, and improved adherence that is transmitted into the polymer matrix to form a nanocomposite with improved properties. Polymethyl methacrylate is a common carbon source for the synthesis of carbon nanofibres of its high mechanical strength, thermal stability, and low moisture and water absorbing capacity that allows its products to have several applications. In this work, we report the successful electrospinning of carbon nanofibres from Poly methyl methacrylate and functionalizing the resulting carbon nanofibres. The functionalized carbon nanofibres were analyzed to determine their solubility/dispersion in selected organic solvents, then characterized using Fourier transform infra-red spectroscopy, Raman spectroscopy, scanning electron microscopy combined with Energy dispersive spectroscopy and Thermalgravimetric analysis.展开更多
粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.12...粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.125 g TNT当量的微型炸药球作为爆炸源,进行填实爆炸产生应力波,通过采集光纤探针端面的运动信息,基于短时傅里叶变换的时频分析方法,解调出端面运动速度,进而反推出粒子速度。实验结果表明:不同光纤镀膜探针测得的速度分别为22.648 m/s、23.505 m/s,将反推的粒子速度与传统的圆环型电磁粒子速度计方法获取到的数据进行对比,两者的相对偏差低于5.00%,验证了光纤镀膜探针测量固体介质中应力波粒子速度的可行性。展开更多
BACKGROUND In children with osteosarcoma around the knee joint without epiphysis involvement,joint-sparing surgery seems to be an ideal way to retain knee joint function.However,there are two points of debate with reg...BACKGROUND In children with osteosarcoma around the knee joint without epiphysis involvement,joint-sparing surgery seems to be an ideal way to retain knee joint function.However,there are two points of debate with regard to the technique:How to accurately achieve a safe surgical margin,and how to achieve intercalary reconstruction of the massive bone defect following resection of the tumor.CASE SUMMARY We present the case of an 8-year-old girl with osteosarcoma of the distal femur without involvement of the epiphysis.Epiphyseal distraction was applied to separate the epiphysis and metaphysis,and this provided a safe surgical margin.The massive bone defect was reconstructed with a custom-made antibioticloaded polymethyl methacrylate(PMMA)construct combined with a free nonvascularized fibular graft.Six months after surgery,bone union between the autograft and host bone was confirmed in both the proximal and distal femur by computer tomography(CT)examination.Moreover,considerable callus formation was found around the PMMA construct.After 28 mo of follow-up,there was no sign of recurrence or metastasis.The patient could walk without any aid and carry out her daily life activities satisfactorily.CONCLUSION In cases of osteosarcoma without epiphysis involvement,epiphyseal distraction can be easily applied to obtain a safe margin.Hybrid reconstruction with an antibiotic-loaded PMMA construct combined with a free non-vascularized fibular graft has the advantages of being easy to manufacture,less time-consuming to place,and less likely to get infected,while also ensuring bone union.Our case provides an alternative technique for biological reconstruction after joint-sparing surgery in patients with osteosarcoma around the knee without epiphyseal involvement.展开更多
Poly methyl methacrylate(PMMA)bone cement is used in augmenting and stabilizing fractured vertebral bodies through percutaneous vertebroplasty(PVP)and percutaneous kyphoplasty(PKP).However,applications of PMMA bone ce...Poly methyl methacrylate(PMMA)bone cement is used in augmenting and stabilizing fractured vertebral bodies through percutaneous vertebroplasty(PVP)and percutaneous kyphoplasty(PKP).However,applications of PMMA bone cement are limited by the high elasticity modulus of PMMA,its low biodegradability,and its limited ability to regenerate bone.To improve PMMA bio activity and biodegradability and to modify its elasticity modulus,we mixed PMMA bone cement with oxidized hyaluronic acid and carboxymethyl chitosan in situ cross-linking hydrogel loaded with bone morphogenetic protein-2(BMP-2)to achieve novel hybrid cement.These fabric ated PMMA-hydrogel hybrid cements exhibited lower setting temperatures,a lower elasticity modulus,and better biodegradability and biocompatibility than that of pure PMMA cement,while retaining acceptable setting times,mechanical strength,and inj ectability.In addition,we detected release of BMP-2 from the PMMA-hydrogel hybrid cements,significantly enhancing in vitro osteogenesis of bone marrow mesenchymal stem cells by up-regulating the gene expression of Runx2,Coll,and OPN.Use of PMMA-hydrogel hybrid cements loaded with BMP-2 on rabbit femoral condyle bone-defect models revealed their biodegradability and enhanced bone formation.Our study demonstrated the favorable mechanical properties,biocompatibility,and biodegradability of fabricated PMMA-hydrogel hybrid cements loaded with BMP-2,as well as their ability to improve osteogenesis,making them a promising material for use in PKP and PVP.展开更多
The biodegradation behavior of Mg,coated by polymethyl methacrylate as well as polymethyl methacrylate(PMMA)−bioactive glass(BG)composite was investigated.Electrophoretic deposition and dip coating techniques were ado...The biodegradation behavior of Mg,coated by polymethyl methacrylate as well as polymethyl methacrylate(PMMA)−bioactive glass(BG)composite was investigated.Electrophoretic deposition and dip coating techniques were adopted to prepare composite coating using a suspension of different percentages of the above two chemical materials.The deposited coatings were characterized using SEM,EDS,FTIR,and water contact angle measurements.Biodegradation behavior study of the coated Mg was performed using linear polarization,impedance spectroscopy,and immersion tests in simulated body fluid.The compact and homogeneous composite coating was developed as evidenced by electron microscopy results.The water contact angle measurement showed a 44°increase in the contact angle of the composite coated Mg compared to the uncoated one.The composite coating was covered by a bone-like hydroxyapatite layer after 336 h,indicating that the coating has an excellent in vitro bioactivity.The electrochemical testing results confirmed a significant reduction,96.9%,in the biodegradation rate of Mg coated with the composite prepared from 45 g/L PMMA+3.5 g/L 45S5 GB suspension compared to that of the uncoated one.Therefore,the composite coated Mg can be proposed as a promising material for biodegradable implant application.展开更多
文摘Carbon nanofibers have revolutionized nanotechnology due to their potential applications in emerging frontiers of research and industrial sectors. This can be attributed to their superior properties such as higher mechanical strength, unique surface characteristics, and improved adherence that is transmitted into the polymer matrix to form a nanocomposite with improved properties. Polymethyl methacrylate is a common carbon source for the synthesis of carbon nanofibres of its high mechanical strength, thermal stability, and low moisture and water absorbing capacity that allows its products to have several applications. In this work, we report the successful electrospinning of carbon nanofibres from Poly methyl methacrylate and functionalizing the resulting carbon nanofibres. The functionalized carbon nanofibres were analyzed to determine their solubility/dispersion in selected organic solvents, then characterized using Fourier transform infra-red spectroscopy, Raman spectroscopy, scanning electron microscopy combined with Energy dispersive spectroscopy and Thermalgravimetric analysis.
文摘粒子速度是分析固体介质中应力波传播规律的一个重要参数。结合激光多普勒效应和全光纤干涉测速系统,提出了一种基于光纤镀膜探针的固体介质中应力波粒子速度的测量方法。将光纤镀膜探针嵌入有机玻璃(PMMA)中,距爆心同一半径处,采用0.125 g TNT当量的微型炸药球作为爆炸源,进行填实爆炸产生应力波,通过采集光纤探针端面的运动信息,基于短时傅里叶变换的时频分析方法,解调出端面运动速度,进而反推出粒子速度。实验结果表明:不同光纤镀膜探针测得的速度分别为22.648 m/s、23.505 m/s,将反推的粒子速度与传统的圆环型电磁粒子速度计方法获取到的数据进行对比,两者的相对偏差低于5.00%,验证了光纤镀膜探针测量固体介质中应力波粒子速度的可行性。
基金Supported by National Natural Science Foundation of China,No.81301671
文摘BACKGROUND In children with osteosarcoma around the knee joint without epiphysis involvement,joint-sparing surgery seems to be an ideal way to retain knee joint function.However,there are two points of debate with regard to the technique:How to accurately achieve a safe surgical margin,and how to achieve intercalary reconstruction of the massive bone defect following resection of the tumor.CASE SUMMARY We present the case of an 8-year-old girl with osteosarcoma of the distal femur without involvement of the epiphysis.Epiphyseal distraction was applied to separate the epiphysis and metaphysis,and this provided a safe surgical margin.The massive bone defect was reconstructed with a custom-made antibioticloaded polymethyl methacrylate(PMMA)construct combined with a free nonvascularized fibular graft.Six months after surgery,bone union between the autograft and host bone was confirmed in both the proximal and distal femur by computer tomography(CT)examination.Moreover,considerable callus formation was found around the PMMA construct.After 28 mo of follow-up,there was no sign of recurrence or metastasis.The patient could walk without any aid and carry out her daily life activities satisfactorily.CONCLUSION In cases of osteosarcoma without epiphysis involvement,epiphyseal distraction can be easily applied to obtain a safe margin.Hybrid reconstruction with an antibiotic-loaded PMMA construct combined with a free non-vascularized fibular graft has the advantages of being easy to manufacture,less time-consuming to place,and less likely to get infected,while also ensuring bone union.Our case provides an alternative technique for biological reconstruction after joint-sparing surgery in patients with osteosarcoma around the knee without epiphyseal involvement.
基金supported by the National Key R&D Program of China(No.2018YFA0703000)the National Natural Science Foundation of China(Nos.82071564,82072412,and 81772326)+1 种基金the Fundamental Research Program Funding of Ninth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine(No.JYZZ070)Project of Shanghai Science and Technology Commission(No.19XD1434200/18431903700)。
文摘Poly methyl methacrylate(PMMA)bone cement is used in augmenting and stabilizing fractured vertebral bodies through percutaneous vertebroplasty(PVP)and percutaneous kyphoplasty(PKP).However,applications of PMMA bone cement are limited by the high elasticity modulus of PMMA,its low biodegradability,and its limited ability to regenerate bone.To improve PMMA bio activity and biodegradability and to modify its elasticity modulus,we mixed PMMA bone cement with oxidized hyaluronic acid and carboxymethyl chitosan in situ cross-linking hydrogel loaded with bone morphogenetic protein-2(BMP-2)to achieve novel hybrid cement.These fabric ated PMMA-hydrogel hybrid cements exhibited lower setting temperatures,a lower elasticity modulus,and better biodegradability and biocompatibility than that of pure PMMA cement,while retaining acceptable setting times,mechanical strength,and inj ectability.In addition,we detected release of BMP-2 from the PMMA-hydrogel hybrid cements,significantly enhancing in vitro osteogenesis of bone marrow mesenchymal stem cells by up-regulating the gene expression of Runx2,Coll,and OPN.Use of PMMA-hydrogel hybrid cements loaded with BMP-2 on rabbit femoral condyle bone-defect models revealed their biodegradability and enhanced bone formation.Our study demonstrated the favorable mechanical properties,biocompatibility,and biodegradability of fabricated PMMA-hydrogel hybrid cements loaded with BMP-2,as well as their ability to improve osteogenesis,making them a promising material for use in PKP and PVP.
文摘The biodegradation behavior of Mg,coated by polymethyl methacrylate as well as polymethyl methacrylate(PMMA)−bioactive glass(BG)composite was investigated.Electrophoretic deposition and dip coating techniques were adopted to prepare composite coating using a suspension of different percentages of the above two chemical materials.The deposited coatings were characterized using SEM,EDS,FTIR,and water contact angle measurements.Biodegradation behavior study of the coated Mg was performed using linear polarization,impedance spectroscopy,and immersion tests in simulated body fluid.The compact and homogeneous composite coating was developed as evidenced by electron microscopy results.The water contact angle measurement showed a 44°increase in the contact angle of the composite coated Mg compared to the uncoated one.The composite coating was covered by a bone-like hydroxyapatite layer after 336 h,indicating that the coating has an excellent in vitro bioactivity.The electrochemical testing results confirmed a significant reduction,96.9%,in the biodegradation rate of Mg coated with the composite prepared from 45 g/L PMMA+3.5 g/L 45S5 GB suspension compared to that of the uncoated one.Therefore,the composite coated Mg can be proposed as a promising material for biodegradable implant application.