The strength and deformation characteristics of polypropylene fiber reinforced concrete ( PFRC) beams were investigated by four-point bending procedures in this paper. Two kinds of polypropylene fibers with different ...The strength and deformation characteristics of polypropylene fiber reinforced concrete ( PFRC) beams were investigated by four-point bending procedures in this paper. Two kinds of polypropylene fibers with different fiber contents (0.2% , 0.5% , 1.0% and 1.5% ) by volume were used in, the beam, which measured 100 × 100 mm with a span of 300 mm. It was found that the strength of the reinforced concrete beams was significantly decreased, whereas the flexural toughness was improved, compared to those unreinforced concrete beams. Geometry properties and volume contents of polypropylene fiber were considered to be important factors for improving the flexural toughness. Moreover, the composite mechanism between polypropylene fiber and concrete was analyzed and discussed.展开更多
In order to investigate the synergistic effect of re-dispersible powder-ethylene-vinyl acetate copolymer(EVA) and polypropylene fiber on the crack resistance of concrete under thermal fatigue loading, the compressive ...In order to investigate the synergistic effect of re-dispersible powder-ethylene-vinyl acetate copolymer(EVA) and polypropylene fiber on the crack resistance of concrete under thermal fatigue loading, the compressive strength, ultimate tensile strength, ultimate tensile strain and tensile modulus of elasticity were tested. In addition, ultrasonic method and scanning electron microscope analysis were used to explain the microstructure mechanism. The results show that polypropylene fiberreinforced concrete presents a better performance on crack resistance than ordinary concrete, and the synergism of EVA and polypropylene fiber can improve the anti-cracking ability of concrete further.展开更多
Apart from many advantages,High Strength Concrete(HSC)has disadvantages in terms of brittleness and poor resistance to fire.Various studies suggest that when polypropylene(PP)fibers are uniformly distributed within co...Apart from many advantages,High Strength Concrete(HSC)has disadvantages in terms of brittleness and poor resistance to fire.Various studies suggest that when polypropylene(PP)fibers are uniformly distributed within concrete,they play an active role in improving spalling resistance of concrete when exposed to elevated temperature while having no adverse effect on its mechanical properties.Therefore,there is a necessity to quantify the effect of the addition of polypropylene fibers in terms of the fiber dosage,the strength of the concrete,and the residual mechanical properties of fiber-reinforced concrete under exposure to high temperature from fire.The study was carried out on three water/cement(w/c)ratios(0.47,0.36&0.20)using granite aggregate for determining short term mechanical properties of Polypropylene fiber reinforced concrete in comparison to control mix.The experimental program includes 100×200 mm&150 x 300 mm cylinders with fiber volume of 0.5%,that were subjected to temperatures exposures of 400°C and 600°C for durations of 1 hour.From the results,it was observed that no significant enhancement in mechanical properties such as modulus of elasticity,Poisson’s ratio,split tensile strength,flexural strength,and compressive strength was observed at room temperature and at elevated temperatures.展开更多
Synthetic fibers made from nylon or polypropylene have gained application when loose and woven into geo textile form although no information on the matrix’s mechanical performance is obtained so that more understandi...Synthetic fibers made from nylon or polypropylene have gained application when loose and woven into geo textile form although no information on the matrix’s mechanical performance is obtained so that more understanding of their structural contribution to resist cracking can be determined. This paper presents the results of an experimental investigation to determine the performance characteristics of concrete reinforced with a polypropylene structural fiber. In this investigation “Fiber mesh” brand of fibers manufactured by SL Concrete System, Tennessee, USA and marketed by M/S Millennium Building System, Inc., Ban-galore, India are used. The lengths of the fibers used were 24 mm. Fiber dosages used were 0.9, 1.8, 2.7 kg/m3. A total of three mixtures, one for each fiber dosage were made. A standard slump cone test was conducted on the fresh concrete mix with and without fibers to determine the workability of the mix. The test program included the evaluation of hardened concrete properties such as compressive, split tensile, modulus of rupture and flexural strengths. The increase in compressive strength is about 36.25%, 26.20%, and 23.75% respectively that of plain concrete. This increase in strength was directly proportional to amount of fibers present in the mix. The increase in flexural strength for Mixes I^III is about 21%, 16.6%, and 23% respectively that of plain concrete specimens. An experimental investigation was also made to study the behaviors of reinforced fibers concrete beams (with longitudinal reinforcements) under two-point loading. The deflection and crack patterns were also studied. The improvements in strength and ductility characteristics were discussed.展开更多
The incorporation of fiber-reinforced-polymer (FRP) bars in construction as a replacement to steel bars provides a superior material which is capable to overcome corrosion problems. However, serviceability requirement...The incorporation of fiber-reinforced-polymer (FRP) bars in construction as a replacement to steel bars provides a superior material which is capable to overcome corrosion problems. However, serviceability requirements are important issues to be considered in the design of concrete elements reinforced with glass-FRP (GFRP) bars which are known to have larger deflections and wider crack widths as well as weaker bond compared with steel reinforced concrete. As a solution to this problem, square GFRP bars are proposed. This paper presents the results of an experimental investigation that was performed, in which newly developed square and circular GFRP bars were fabricated in the lab. Also, the GFRP bars were tested and used to reinforce concrete slabs. A total of nine full-scale GFRP-reinforced concrete (RC) one-way slabs were constructed, tested and analyzed, considering the most influencing parameters such as the cross sectional shape of GFRP bars, reinforcement ratio, the concrete characteristics strength, and adding polypropylene fibers to the concrete mixture. The test results were showed that, the tested slabs with GFRP square bars improved the deflection and cracking behavior as well as the ultimate load.展开更多
To study the damage evolution behavior of polypropylene fiber reinforced concrete(PFRC)subjected to sulfate attack,a uniaxial compression test was carried out based on acoustic emission(AE).The effect of sulfate attac...To study the damage evolution behavior of polypropylene fiber reinforced concrete(PFRC)subjected to sulfate attack,a uniaxial compression test was carried out based on acoustic emission(AE).The effect of sulfate attack relative to time and fiber hybridization were analyzed and the compression damage factor was calculated using a mathematical model.The changes to AE ringing counts during the compression could be divided into compaction,elastic,and AE signal hyperactivity stages.In the initial stage of sulfate attack,the concrete micropores and microcracks were compacted gradually under external load and a corrosion products filling effect,and this corresponded with detection of few AE signals and with concrete compression strength enhancement.With increasing sulfate attack time,AE activity decreased.The cumulative AE ringing counts of PFRC at all corrosion ages were much higher than those for plain concrete.PFRC could still produce AE signals after peak load due to drawing effect of polypropylene fiber.After 150 d of sulfate attack,the cumulative AE ringing counts of plain concrete went down by about an order of magnitude,while that for PFRC remained at a high level.The initial damage factor of hybrid PFRC was-0.042 and-0.056 respectively after 150 d of corrosion,indicating that the advantage of hybrid polypropylene fiber was more obvious than plain concrete and single-doped PFRC.Based on a deterioration equation,the corrosion resistance coefficient of hybrid PFRC would be less than 0.75 after 42 drying-wetting sulfate attack cycles,which was 40%longer than that of plain concrete.展开更多
基金Supported by Natural Science Foundation of China (No. 59908007) and Foundation for University Key Teacher by the Min-istry of Education (GG - 430 - 10247 - 1175).
文摘The strength and deformation characteristics of polypropylene fiber reinforced concrete ( PFRC) beams were investigated by four-point bending procedures in this paper. Two kinds of polypropylene fibers with different fiber contents (0.2% , 0.5% , 1.0% and 1.5% ) by volume were used in, the beam, which measured 100 × 100 mm with a span of 300 mm. It was found that the strength of the reinforced concrete beams was significantly decreased, whereas the flexural toughness was improved, compared to those unreinforced concrete beams. Geometry properties and volume contents of polypropylene fiber were considered to be important factors for improving the flexural toughness. Moreover, the composite mechanism between polypropylene fiber and concrete was analyzed and discussed.
基金Funded by National Key R&D Program(No.2016YFC0701003)of Chinathe Fundamental Research Funds for the Central Universities
文摘In order to investigate the synergistic effect of re-dispersible powder-ethylene-vinyl acetate copolymer(EVA) and polypropylene fiber on the crack resistance of concrete under thermal fatigue loading, the compressive strength, ultimate tensile strength, ultimate tensile strain and tensile modulus of elasticity were tested. In addition, ultrasonic method and scanning electron microscope analysis were used to explain the microstructure mechanism. The results show that polypropylene fiberreinforced concrete presents a better performance on crack resistance than ordinary concrete, and the synergism of EVA and polypropylene fiber can improve the anti-cracking ability of concrete further.
文摘Apart from many advantages,High Strength Concrete(HSC)has disadvantages in terms of brittleness and poor resistance to fire.Various studies suggest that when polypropylene(PP)fibers are uniformly distributed within concrete,they play an active role in improving spalling resistance of concrete when exposed to elevated temperature while having no adverse effect on its mechanical properties.Therefore,there is a necessity to quantify the effect of the addition of polypropylene fibers in terms of the fiber dosage,the strength of the concrete,and the residual mechanical properties of fiber-reinforced concrete under exposure to high temperature from fire.The study was carried out on three water/cement(w/c)ratios(0.47,0.36&0.20)using granite aggregate for determining short term mechanical properties of Polypropylene fiber reinforced concrete in comparison to control mix.The experimental program includes 100×200 mm&150 x 300 mm cylinders with fiber volume of 0.5%,that were subjected to temperatures exposures of 400°C and 600°C for durations of 1 hour.From the results,it was observed that no significant enhancement in mechanical properties such as modulus of elasticity,Poisson’s ratio,split tensile strength,flexural strength,and compressive strength was observed at room temperature and at elevated temperatures.
文摘Synthetic fibers made from nylon or polypropylene have gained application when loose and woven into geo textile form although no information on the matrix’s mechanical performance is obtained so that more understanding of their structural contribution to resist cracking can be determined. This paper presents the results of an experimental investigation to determine the performance characteristics of concrete reinforced with a polypropylene structural fiber. In this investigation “Fiber mesh” brand of fibers manufactured by SL Concrete System, Tennessee, USA and marketed by M/S Millennium Building System, Inc., Ban-galore, India are used. The lengths of the fibers used were 24 mm. Fiber dosages used were 0.9, 1.8, 2.7 kg/m3. A total of three mixtures, one for each fiber dosage were made. A standard slump cone test was conducted on the fresh concrete mix with and without fibers to determine the workability of the mix. The test program included the evaluation of hardened concrete properties such as compressive, split tensile, modulus of rupture and flexural strengths. The increase in compressive strength is about 36.25%, 26.20%, and 23.75% respectively that of plain concrete. This increase in strength was directly proportional to amount of fibers present in the mix. The increase in flexural strength for Mixes I^III is about 21%, 16.6%, and 23% respectively that of plain concrete specimens. An experimental investigation was also made to study the behaviors of reinforced fibers concrete beams (with longitudinal reinforcements) under two-point loading. The deflection and crack patterns were also studied. The improvements in strength and ductility characteristics were discussed.
文摘The incorporation of fiber-reinforced-polymer (FRP) bars in construction as a replacement to steel bars provides a superior material which is capable to overcome corrosion problems. However, serviceability requirements are important issues to be considered in the design of concrete elements reinforced with glass-FRP (GFRP) bars which are known to have larger deflections and wider crack widths as well as weaker bond compared with steel reinforced concrete. As a solution to this problem, square GFRP bars are proposed. This paper presents the results of an experimental investigation that was performed, in which newly developed square and circular GFRP bars were fabricated in the lab. Also, the GFRP bars were tested and used to reinforce concrete slabs. A total of nine full-scale GFRP-reinforced concrete (RC) one-way slabs were constructed, tested and analyzed, considering the most influencing parameters such as the cross sectional shape of GFRP bars, reinforcement ratio, the concrete characteristics strength, and adding polypropylene fibers to the concrete mixture. The test results were showed that, the tested slabs with GFRP square bars improved the deflection and cracking behavior as well as the ultimate load.
基金The support from Mechanical Effect and Safety Analysis of Severely Damaged Tunnel Renovation Process(No.H20210058)is gratefully acknowledged.
文摘To study the damage evolution behavior of polypropylene fiber reinforced concrete(PFRC)subjected to sulfate attack,a uniaxial compression test was carried out based on acoustic emission(AE).The effect of sulfate attack relative to time and fiber hybridization were analyzed and the compression damage factor was calculated using a mathematical model.The changes to AE ringing counts during the compression could be divided into compaction,elastic,and AE signal hyperactivity stages.In the initial stage of sulfate attack,the concrete micropores and microcracks were compacted gradually under external load and a corrosion products filling effect,and this corresponded with detection of few AE signals and with concrete compression strength enhancement.With increasing sulfate attack time,AE activity decreased.The cumulative AE ringing counts of PFRC at all corrosion ages were much higher than those for plain concrete.PFRC could still produce AE signals after peak load due to drawing effect of polypropylene fiber.After 150 d of sulfate attack,the cumulative AE ringing counts of plain concrete went down by about an order of magnitude,while that for PFRC remained at a high level.The initial damage factor of hybrid PFRC was-0.042 and-0.056 respectively after 150 d of corrosion,indicating that the advantage of hybrid polypropylene fiber was more obvious than plain concrete and single-doped PFRC.Based on a deterioration equation,the corrosion resistance coefficient of hybrid PFRC would be less than 0.75 after 42 drying-wetting sulfate attack cycles,which was 40%longer than that of plain concrete.