Experiments were carried out to design polyvinyl alcohol (PVA) fiber reinforced cementitous composites (PVA-FRCCs) holding high ductility and energy consumption ability. Besides, the properties of each ingredients...Experiments were carried out to design polyvinyl alcohol (PVA) fiber reinforced cementitous composites (PVA-FRCCs) holding high ductility and energy consumption ability. Besides, the properties of each ingredients in composites, mixing method and technology for fresh mixture were described in detail. Then, the pseudo-strain-hardening (PSH) behavior was investigated in uniaxial tension test. As a result, the maximum ultimate tensile strain can reach 0.7 percent. On the other hand, the single edge notch (SEN) thin sheet specimens were employed to gain the normal tensile load via crack mouth opening displacement (CMOD) curves, which can show obvious PSH behavior. In addition, the curves can be divided into four zones whose fracture toughness calculation methods were discussed. The wedge splitting (WS) test method can be applied to discuss the fracture toughness. Moreover, fracture energy of SEN and WS specimens were both approximately evaluated.展开更多
A PVA-GAG-COL composite scaffold is fabricated by polyvinyl alcohol (PVA), glyeosaminoglycan (GAG) and collagen (COL). Laser surface modification technology is used to make holes on the surface of the scaffolds....A PVA-GAG-COL composite scaffold is fabricated by polyvinyl alcohol (PVA), glyeosaminoglycan (GAG) and collagen (COL). Laser surface modification technology is used to make holes on the surface of the scaffolds. Inside and outside interconnection micro-porous structure is obtained. Bioeompatibility test of the scaffolds shows that PVA-GAG-COL scaffold can promote the adhesion and proliferation of the fibroblast. Also, fibroblast can grow normally on the scaffolds with pore diameter from 115 um to 255 um and pore distance from 500 um to 2000 um. PVA-GAG-COL scaffolds possess excellent cell biocompatibility. The porous structure is suitable for cell culture in tissue engineering.展开更多
This paper presents an experimental study of the possibility of transition from multiple macro-cracking to multiple micro-cracking in cementitious composites. Conventional polyvinyl alcohol fiber reinforced cementitio...This paper presents an experimental study of the possibility of transition from multiple macro-cracking to multiple micro-cracking in cementitious composites. Conventional polyvinyl alcohol fiber reinforced cementitious composites normally exhibit macroscopic strain-hardening and multiple cracking after the first cracks appear. However, the individual crack width at the saturated stage is normally 60 to 80 μm. In the current study, the effect of fine aggregate size on the cracking performance, especially the individual crack width in the strain-hardening stage was studied by bending tests. The results show that the individual crack widths can be reduced from 60-80 μm to 10-30 μm by modifying the particle size of the fine aggregates used in the composites.展开更多
The objective of this paper is to design a based on composite membrane with certain mechanical porous polyvinyl alcohol (PVA) strength and biocompatibilities serving as tissue regenerative scaffolds. PVA-glycosamino...The objective of this paper is to design a based on composite membrane with certain mechanical porous polyvinyl alcohol (PVA) strength and biocompatibilities serving as tissue regenerative scaffolds. PVA-glycosaminoglycan (GAG)-type I collagen (COL) composite membrane was fabricated by PVA with different molecular weight (Mw) and alcoholysis degree (AD) being blended with certain amounts of GAG and COL and dried at 38~C for 24 h. The water content of the composite membranes were from 61.9% to 95.1% and swelling ratio ranged from 123.6% to 621.7%. Scanning electron micro- scope (SEM) analysis proved that PVA-GAG-COL composite membrane has porous and homogenous structure. Biocompatibility test results showed that the composite membrane was nontoxic, which could promote adhesion and proliferation of fibroblasts on the com- posite membrane. In conclusion, PVA-GAG-COL composite membrane with high water content and swelling ratio, suitable mechanical strength and good biocompatibility, has potential in tissue engineering and regenerative medicine.展开更多
基金Committee on Science and Technology Foundation of China(No.50438010)The Research of Formation Progress and Control Technology of Concrete Structure Cracks
文摘Experiments were carried out to design polyvinyl alcohol (PVA) fiber reinforced cementitous composites (PVA-FRCCs) holding high ductility and energy consumption ability. Besides, the properties of each ingredients in composites, mixing method and technology for fresh mixture were described in detail. Then, the pseudo-strain-hardening (PSH) behavior was investigated in uniaxial tension test. As a result, the maximum ultimate tensile strain can reach 0.7 percent. On the other hand, the single edge notch (SEN) thin sheet specimens were employed to gain the normal tensile load via crack mouth opening displacement (CMOD) curves, which can show obvious PSH behavior. In addition, the curves can be divided into four zones whose fracture toughness calculation methods were discussed. The wedge splitting (WS) test method can be applied to discuss the fracture toughness. Moreover, fracture energy of SEN and WS specimens were both approximately evaluated.
基金863 Program grant number: 2077AA09Z436+1 种基金Guangdong Province '211' Fund for Biomaterials and Tissue Engineering grantnumber: 50621030
文摘A PVA-GAG-COL composite scaffold is fabricated by polyvinyl alcohol (PVA), glyeosaminoglycan (GAG) and collagen (COL). Laser surface modification technology is used to make holes on the surface of the scaffolds. Inside and outside interconnection micro-porous structure is obtained. Bioeompatibility test of the scaffolds shows that PVA-GAG-COL scaffold can promote the adhesion and proliferation of the fibroblast. Also, fibroblast can grow normally on the scaffolds with pore diameter from 115 um to 255 um and pore distance from 500 um to 2000 um. PVA-GAG-COL scaffolds possess excellent cell biocompatibility. The porous structure is suitable for cell culture in tissue engineering.
基金the National Natural Science Foundation of China (No. 50178043)
文摘This paper presents an experimental study of the possibility of transition from multiple macro-cracking to multiple micro-cracking in cementitious composites. Conventional polyvinyl alcohol fiber reinforced cementitious composites normally exhibit macroscopic strain-hardening and multiple cracking after the first cracks appear. However, the individual crack width at the saturated stage is normally 60 to 80 μm. In the current study, the effect of fine aggregate size on the cracking performance, especially the individual crack width in the strain-hardening stage was studied by bending tests. The results show that the individual crack widths can be reduced from 60-80 μm to 10-30 μm by modifying the particle size of the fine aggregates used in the composites.
基金National Natural Science Foundation of China,grant number:51070853Guangzhou Technology Plans,grant number:2010B103315 and 2010J-E041
文摘The objective of this paper is to design a based on composite membrane with certain mechanical porous polyvinyl alcohol (PVA) strength and biocompatibilities serving as tissue regenerative scaffolds. PVA-glycosaminoglycan (GAG)-type I collagen (COL) composite membrane was fabricated by PVA with different molecular weight (Mw) and alcoholysis degree (AD) being blended with certain amounts of GAG and COL and dried at 38~C for 24 h. The water content of the composite membranes were from 61.9% to 95.1% and swelling ratio ranged from 123.6% to 621.7%. Scanning electron micro- scope (SEM) analysis proved that PVA-GAG-COL composite membrane has porous and homogenous structure. Biocompatibility test results showed that the composite membrane was nontoxic, which could promote adhesion and proliferation of fibroblasts on the com- posite membrane. In conclusion, PVA-GAG-COL composite membrane with high water content and swelling ratio, suitable mechanical strength and good biocompatibility, has potential in tissue engineering and regenerative medicine.