Heterojunctions between polyaniline (PANI) and n-type porous silicon (PS), Al/PS-PANI/Au cell, were fabricated, and the rectifying parameters of this heterojunction diode were measured as a function of the preparation...Heterojunctions between polyaniline (PANI) and n-type porous silicon (PS), Al/PS-PANI/Au cell, were fabricated, and the rectifying parameters of this heterojunction diode were measured as a function of the preparation conditions of PANI and PS, the electronic structure of PANI as well as cell structure. The rectifying parameters of Al/PS-PANI/Au cell were determined to be gamma = 1.8x10(1) similar to 1.0x10(5) for the rectifying ratio at 3V, n = 3 similar to 12 for the ideal factor, j(0) = 8.0x10(-5) similar to 5.6x10(-2) mA/cm(2) for the reversed saturated current density, and phi(0) = 0.67 similar to 0.83 V for the barrier height, respectively. The best rectifying heterojunction diode made between PANI and n-type PS with higher rectifying factor (gamma = 1.0x10(5) at 3V), output current (>1500 mA/cm(2) at 3V) and lower ideal factor (n = 3.3) was obtained by preventing the oxidation of PS before evaporating Al electrode.展开更多
The equation for calculating the effective refractive index of porous silicon inserted polymer was obtained by three-component Bruggeman effective medium model. The dependence of the effective refractive index of poro...The equation for calculating the effective refractive index of porous silicon inserted polymer was obtained by three-component Bruggeman effective medium model. The dependence of the effective refractive index of porous silicon/polymer composite films on the polymer fraction with various initial porosity was given theorically and experimentally respectively. The porous silicon and polymer polymethylmetacrylate based dispersive red one (PMMA/DR1) composite films were fabricated in our experiments. It is found that the measured effective refractive index of porous silicon inserted polymer was slightly lower than the calculated result because of the oxidization of porous silicon. The effective refractive index of oxidized porous silicon inserted polymer also was analyzed by four-component medium system.展开更多
基金The project was supported by the Foundation of Chinese Academy of Sciences.
文摘Heterojunctions between polyaniline (PANI) and n-type porous silicon (PS), Al/PS-PANI/Au cell, were fabricated, and the rectifying parameters of this heterojunction diode were measured as a function of the preparation conditions of PANI and PS, the electronic structure of PANI as well as cell structure. The rectifying parameters of Al/PS-PANI/Au cell were determined to be gamma = 1.8x10(1) similar to 1.0x10(5) for the rectifying ratio at 3V, n = 3 similar to 12 for the ideal factor, j(0) = 8.0x10(-5) similar to 5.6x10(-2) mA/cm(2) for the reversed saturated current density, and phi(0) = 0.67 similar to 0.83 V for the barrier height, respectively. The best rectifying heterojunction diode made between PANI and n-type PS with higher rectifying factor (gamma = 1.0x10(5) at 3V), output current (>1500 mA/cm(2) at 3V) and lower ideal factor (n = 3.3) was obtained by preventing the oxidation of PS before evaporating Al electrode.
基金This work was supported by the National NaturalScience Foundation of China (No. 60267001), the WestGlory Project of Chinese Academy of Science, and theEncourage and Reward Project for Outstanding YoungScholar of Xinjiang (No. XJEDU2004E02).
文摘The equation for calculating the effective refractive index of porous silicon inserted polymer was obtained by three-component Bruggeman effective medium model. The dependence of the effective refractive index of porous silicon/polymer composite films on the polymer fraction with various initial porosity was given theorically and experimentally respectively. The porous silicon and polymer polymethylmetacrylate based dispersive red one (PMMA/DR1) composite films were fabricated in our experiments. It is found that the measured effective refractive index of porous silicon inserted polymer was slightly lower than the calculated result because of the oxidization of porous silicon. The effective refractive index of oxidized porous silicon inserted polymer also was analyzed by four-component medium system.