To study the differences in homing potential between bone marrow cells and umbilical blood cells, CD34 positive cells were obtained from bone marrow (BM) and umbilical blood (UB) by the direct cell separation with dom...To study the differences in homing potential between bone marrow cells and umbilical blood cells, CD34 positive cells were obtained from bone marrow (BM) and umbilical blood (UB) by the direct cell separation with domestic immunomagnetic beads. The expression of the two adhesion molecules CD11a/CD18 and CD44 were examined. After separation, CD34 positive cells accounted for 51 %-82 % of the harvested cells and dye-resistance rate was 82 %-88 %. The expression of CD11a/CD18 and CD44 on the surfaces of UB cells was 49. 6 % 1 10. 2 % and 37. 7 % ± 10. 3 % respectively. On BM cells they were 50. 2 % ± 6. 2 % and 34 % ± 13. 3 % respectively. There were no significant differences in the expression of these two molecules. It was concluded .that the cell separation method with domestic immunomagnetic beads was effective and the stem cells from UB could serve as an alternative source for transplantation.展开更多
Two multicapillary coluumns(SE 30 and Carbowax 20M)were used for high speed GC separation of positional isomers of industrial chemicals The performances of the two multicapillary columns were also evaluated,such a...Two multicapillary coluumns(SE 30 and Carbowax 20M)were used for high speed GC separation of positional isomers of industrial chemicals The performances of the two multicapillary columns were also evaluated,such as the effects of carrier velocity,column temperature and sample capacity Two typical explosive isomers(DNT and TNT)were well separated on SE 30 multicapillary column,while some important chemicals(e g xylenes,xylenols)were separated on Carbowax 20M multicapillary column at high speed The multimulticapillary column shows the feature of fast analysis,relatively lower column temperature and larger sample capacity展开更多
An insoluble β-cyclodextrin polymer cross-linked with epichlorohydrin was prepared, and its structure was identified with infrared spectrum. Colloid stationary phase was prepared by dissolving the polymer in the mixe...An insoluble β-cyclodextrin polymer cross-linked with epichlorohydrin was prepared, and its structure was identified with infrared spectrum. Colloid stationary phase was prepared by dissolving the polymer in the mixed solvent of diisopropyl ether, methylene dichloride and benzene and treated for 0.5 h by ultrasonication, and then was coated on a fused silica capillary column. The optimun reaction conditions are as follows: the mole ratio of epichlohydrin to β-cyclodextrin is 12.1:1, reacting at 65 °C for 24 h. The Chromatographic performance such as column efficiency, thermal stabilities and polarity were studied, two kinds of disubstituted benzene isomers and eight pairs of enantiomers were separated on the capillary column. The results show that the β-cyclodextrin polymer is suitable for use as a capillary gas chromatographic stationary phase, and possess excellent chromatographic properties in separating enantiomers and position isomers.展开更多
The problem of separating gravitation from inertia is discussed in very general sense, and the conclusion is positive: man can separate gravitation from inertia, if various observation techniques are applied for. The ...The problem of separating gravitation from inertia is discussed in very general sense, and the conclusion is positive: man can separate gravitation from inertia, if various observation techniques are applied for. The accelerometer's position problem in satellite gravimetry is investigated, and the additional acceleration effect due to the position error of an instrument as well as the difference between the mass center and the gravity center is explored.展开更多
A sufficient and necessary criterion for separability of bipartite quantum states is presented. We construct a class of mixed states in 2 k quantum systems and in 3 k quantum systems, respectively and show that thes...A sufficient and necessary criterion for separability of bipartite quantum states is presented. We construct a class of mixed states in 2 k quantum systems and in 3 k quantum systems, respectively and show that these states are separable if and only if they are positive partial transpositions.展开更多
Laser tracers are a three-dimensional coordinate measurement system that are widely used in industrial measurement.We propose a geometric error identification method based on multi-station synchronization laser tracer...Laser tracers are a three-dimensional coordinate measurement system that are widely used in industrial measurement.We propose a geometric error identification method based on multi-station synchronization laser tracers to enable the rapid and high-precision measurement of geometric errors for gantry-type computer numerical control(CNC)machine tools.This method also improves on the existing measurement efficiency issues in the single-base station measurement method and multi-base station time-sharing measurement method.We consider a three-axis gantry-type CNC machine tool,and the geometric error mathematical model is derived and established based on the combination of screw theory and a topological analysis of the machine kinematic chain.The four-station laser tracers position and measurement points are realized based on the multi-point positioning principle.A self-calibration algorithm is proposed for the coordinate calibration process of a laser tracer using the Levenberg-Marquardt nonlinear least squares method,and the geometric error is solved using Taylor’s first-order linearization iteration.The experimental results show that the geometric error calculated based on this modeling method is comparable to the results from the Etalon laser tracer.For a volume of 800 mm×1000 mm×350 mm,the maximum differences of the linear,angular,and spatial position errors were 2.0μm,2.7μrad,and 12.0μm,respectively,which verifies the accuracy of the proposed algorithm.This research proposes a modeling method for the precise measurement of errors in machine tools,and the applied nature of this study also makes it relevant both to researchers and those in the industrial sector.展开更多
文摘To study the differences in homing potential between bone marrow cells and umbilical blood cells, CD34 positive cells were obtained from bone marrow (BM) and umbilical blood (UB) by the direct cell separation with domestic immunomagnetic beads. The expression of the two adhesion molecules CD11a/CD18 and CD44 were examined. After separation, CD34 positive cells accounted for 51 %-82 % of the harvested cells and dye-resistance rate was 82 %-88 %. The expression of CD11a/CD18 and CD44 on the surfaces of UB cells was 49. 6 % 1 10. 2 % and 37. 7 % ± 10. 3 % respectively. On BM cells they were 50. 2 % ± 6. 2 % and 34 % ± 13. 3 % respectively. There were no significant differences in the expression of these two molecules. It was concluded .that the cell separation method with domestic immunomagnetic beads was effective and the stem cells from UB could serve as an alternative source for transplantation.
文摘Two multicapillary coluumns(SE 30 and Carbowax 20M)were used for high speed GC separation of positional isomers of industrial chemicals The performances of the two multicapillary columns were also evaluated,such as the effects of carrier velocity,column temperature and sample capacity Two typical explosive isomers(DNT and TNT)were well separated on SE 30 multicapillary column,while some important chemicals(e g xylenes,xylenols)were separated on Carbowax 20M multicapillary column at high speed The multimulticapillary column shows the feature of fast analysis,relatively lower column temperature and larger sample capacity
文摘An insoluble β-cyclodextrin polymer cross-linked with epichlorohydrin was prepared, and its structure was identified with infrared spectrum. Colloid stationary phase was prepared by dissolving the polymer in the mixed solvent of diisopropyl ether, methylene dichloride and benzene and treated for 0.5 h by ultrasonication, and then was coated on a fused silica capillary column. The optimun reaction conditions are as follows: the mole ratio of epichlohydrin to β-cyclodextrin is 12.1:1, reacting at 65 °C for 24 h. The Chromatographic performance such as column efficiency, thermal stabilities and polarity were studied, two kinds of disubstituted benzene isomers and eight pairs of enantiomers were separated on the capillary column. The results show that the β-cyclodextrin polymer is suitable for use as a capillary gas chromatographic stationary phase, and possess excellent chromatographic properties in separating enantiomers and position isomers.
基金Funded by the National Natural Science Foundation of China (No.40374004)the Foundation of the Key Laboratory of Geo-space Environment and Geodesy, Ministry of Education, China (No.03-04-13).
文摘The problem of separating gravitation from inertia is discussed in very general sense, and the conclusion is positive: man can separate gravitation from inertia, if various observation techniques are applied for. The accelerometer's position problem in satellite gravimetry is investigated, and the additional acceleration effect due to the position error of an instrument as well as the difference between the mass center and the gravity center is explored.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11101017 and 11275131)Beijing Natural Science Foundation Program,and the Scientific Research Key Program of Beijing Municipal Commission of Education(Grant No.KZ201210028032)the Importation and Developmentof High-Caliber Talents Project of Beijing Municipal Institutions(Grant No.CIT&TCD201404067)
文摘A sufficient and necessary criterion for separability of bipartite quantum states is presented. We construct a class of mixed states in 2 k quantum systems and in 3 k quantum systems, respectively and show that these states are separable if and only if they are positive partial transpositions.
基金Supported by Natural Science Foundation of Shaanxi Province of China(Grant No.2021JM010)Suzhou Municipal Natural Science Foundation of China(Grant Nos.SYG202018,SYG202134).
文摘Laser tracers are a three-dimensional coordinate measurement system that are widely used in industrial measurement.We propose a geometric error identification method based on multi-station synchronization laser tracers to enable the rapid and high-precision measurement of geometric errors for gantry-type computer numerical control(CNC)machine tools.This method also improves on the existing measurement efficiency issues in the single-base station measurement method and multi-base station time-sharing measurement method.We consider a three-axis gantry-type CNC machine tool,and the geometric error mathematical model is derived and established based on the combination of screw theory and a topological analysis of the machine kinematic chain.The four-station laser tracers position and measurement points are realized based on the multi-point positioning principle.A self-calibration algorithm is proposed for the coordinate calibration process of a laser tracer using the Levenberg-Marquardt nonlinear least squares method,and the geometric error is solved using Taylor’s first-order linearization iteration.The experimental results show that the geometric error calculated based on this modeling method is comparable to the results from the Etalon laser tracer.For a volume of 800 mm×1000 mm×350 mm,the maximum differences of the linear,angular,and spatial position errors were 2.0μm,2.7μrad,and 12.0μm,respectively,which verifies the accuracy of the proposed algorithm.This research proposes a modeling method for the precise measurement of errors in machine tools,and the applied nature of this study also makes it relevant both to researchers and those in the industrial sector.